33
HCD-C5
SECTION 5
ELECTRICAL ADJUSTMENTS
CD  SECTION
Note 1:
1. CD Block is basically designed to operate without adjustment. There-
fore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
Note 2:
As the laser diode in the optical pick-up (OPTIMA-720L1E) is easily
damaged by static electricity, solder the laser tap of the flexible
board when handling it. Before disconnecting the connector, solder
first. Before connecting the connector, be careful not to remove the
solder. Also take adequate measures to prevent damage by static
electricity. Handle the flexible board with care as it breaks easily.
RF Level Check
Connection:
Procedure:
1. Connect an oscilloscope to test point TP (RFAC) and TP (DVC
1.65V) on the BD (CD) board.
2. Turn the power on.
3. Put the disc (YEDS-18) in to playback the number five track.
4. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
Note:
A clear RF signal waveform means that the shape “
” can be clearly
distinguished at the center of the waveform.
                    RF signal waveform
Checking Location: BD (CD) board
+
BD (CD) board
TP (RFAC)
TP (DVC 1.65V)
oscilloscope
(AC range)
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 1.1 
±
0.3 Vp-p
pick-up
frexible board
laser tap
Checking Location:
– BD (CD) BOARD –
TP 
(RFAC)
TP
(DVC 1.65V)
IC103
IC101
34
HCD-C5
Other faults are suspected.
Check the mechanism parts (spindle motor, sled motor, etc.).
Start
NG
NG
NG
OK
OK
OK
Laser Power Check
6-2.
(See page 37)
6-3.
(See page 37)
6-4.
(See page 38)
Iop Compare
Auto Check
Replace optical pick-up or MDM-7B4B
MD  SECTION
Note 1:
About “R”
As this unit has only a few buttons, some operations require the use of remote commander (RM-SC5BEN/provided with unit: 1-476-649-11)
buttons. These operations are indicated as “R” in this manual.
Example:  
MENU/NO “R”
  ...Press the  
MENU/NO
  button of the remote commander.
Note 2:
Incorrect operations may be performed if the MD test mode is not entered properly.
In this case, press the  
?/1
  button to turn the power off, and retry to enter the MD test mode.
1. PARTS  REPLACEMENT  AND  ADJUSTMENT
If malfunctions caused by optical pick-up such as sound skipping are suspected, follow the following check.
Check before replacement
35
HCD-C5
6-4. Auto Check
(See page 38)
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
Replace IC195
Replace OP or IC195
Replace IC101, IC195, or D101
11. Iop NV SAVE (See page 41)
Replace OP, IC190, or IC195
Replace OP, IC102, IC190, 
or IC195
Replace OP, IC101, IC151, 
or IC195
Replace OP
After turning off and then on the power, 
initialize the EEPROM
For details, refer to “WHEN MEMORY NG IS DIS- 
PLAYED” in Section 4. TEST MODE (See page 29)
• Abbreviation
OP: optical pick-up
7. INITIAL SETTING OF ADJUSTMENT VALUE 
(See page 40)
9. TEMPERATURE COMPENSATION OFFSET 
ADJUSTMENT (See page 40)
10. LASER POWER ADJUSTMENT (See page 40)
12. TRAVERSE ADJUSTMENT (See page 41)
13. FOCUS BIAS ADJUSTMENT (See page 43)
16. AUTO GAIN CONTROL OUTPUT LEVEL
ADJUSTMENT (See page 44)
8. RECORDING AND DISPLAYING THE IOP 
INFORMATION  (See page 40)
End adjustments
Start
Adjustment flow
36
HCD-C5
2. PRECAUTIONS FOR CHECKING LASER DIODE
EMISSION
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
3. PRECAUTIONS FOR USE OF OPTICAL PICK-UP
(KMS-260B/260E)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when handling
it.
Before disconnecting the connector, solder first. Before connecting
the connector, be careful not to remove the solder. Also take adequate
measures to prevent damage by static electricity. Handle the flexible
board with care as it breaks easily.
Optical pick-up flexible board
pick-up
flexible board
laser tap
4. PRECAUTIONS FOR ADJUSTMENTS
1. When replacing the following parts, perform the adjustments
and checks with 
 in the order shown in the following table.
2. Set the MD test mode when performing adjustments.
After completing the adjustments, exit the MD test mode.
Perform the adjustments and checks in “Group Service” of the
MD test mode.
3. Perform the adjustments to be needed in the order shown.
4. Use the following tools and measuring devices.
• Check Disc (TDYS-1) (Part No. : 4-963-646-01)
• Test Disk (MDW-74/GA-1) (Part No. : 4-229-747-01)
• Laser power meter LPM-8001 (Part No. : J-2501-046-A)
or MD Laser power meter 8010S (Part No. : J-2501-145-A)*
1
• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD (MD) board waveform
(Part No. : J-2501-196-A)
5. When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the
oscilloscope.
(VC and ground will become short-circuited.)
6. Using the above jig enables the waveform to be checked without
the need to solder.
(Refer to Servicing Notes on page 6.)
7. As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
*
1
Laser power meter
When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (Part
No. J-2501-145-A) instead of the conventional laser power
meter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of optical pick-up.
7.
Initial setting of adjustment value
8.
Recording of Iop information
9.
Temperature compensation
offset adjustment
10. Laser power adjustment
11. Iop NV Save
12. Traverse adjustment
13. Focus bias adjustment
16. Auto gain control output level
adjustment
6-4. AUTO CHECK
Optical
Pick-up
IC101
IC102
IC151
IC190
IC195
D101
Parts to be replaced
Adjustment
Page of 97
Display