29
HCD-C5
IOP  DATA  RECORDING  AND  DISPLAY  WHEN  OPTI-
CAL  PICK-UP  AND  NON-VOLATILE  MEMORY (IC195
OF  BD (MD) BOARD) ARE  REPLACED
The IOP value labeled on the optical pick-up can be recorded in
the non-volatile memory. By recording the value, it will eliminate
the need to look at the value on the label of the optical pick-up.
When replacing the optical pick-up or non-volatile memory (IC195
of BD (MD) board), record the IOP value on the optical pick-up
according to the following procedure.
Record Procedure:
1. Press the  ?/1  button to turn the power on.
2. Press the  
FUNCTION 
z  button to set the MD function.
3. Press three buttons of  
VOL -
 ,  x  and 
 CD SYNC HIGH
  ,
simultaneously to enter the MD test mode and display
“[Check]”.
4. Press the  . 
“R”
  or  > 
“R”
  button to display
“[Service]”.
5. Press the  
ENTER/YES  “R”
  button to display “AUTO
CHECK”, and press the  > 
“R”
  button to display “Iop
Write”.
6. Press the  
ENTER/YES “R”
  button.
7. The display becomes “Ref= @@@.@” (@ is an arbitrary num-
ber) and the numbers which can be changed will blink.
8. Input the IOP value written on the optical pick-up.
To select the number : Press the
“R”
or > 
“R”
button.
To select the digit :
Press two buttons of  
VOL -
  and
CD 
Z  simultaneously.
9. When the
ENTER/YES  “R”
button is pressed, the display
becomes “Measu=@@@.@” (@ is an arbitrary number).
10. As the adjustment results are recorded for the step 9 value.
Leave it as it is and press the  
ENTER/YES “R”
  button.
11. “Complete!” will be displayed momentarily. The value will
be recorded in the non-volatile memory and the display will
become “Iop Write”.
12. Press the  
REPEAT “R”
  button, or press two buttons of
VOL -
  and  
MD 
Z  simultaneously. to complete. “Initialize”
will be displayed and release the MD test mode.
Display Precedure:
1. Press the  ?/1  button to turn the power on.
2. Press the  
FUNCTION 
z  button to set the MD function.
3. Press three buttons of  
VOL -
  ,  x  , and 
 CD SYNC HIGH
simultaneously to enter the MD test mode and display
“[Check]”.
4. Press the  . 
“R”
  or  > 
“R”
  button to display “[Ser-
vice]”.
5. Press the  
ENTER/YES  “R”
  button to display “AUTO
CHECK”, and press the  > 
“R”
  button to display “Iop Read”.
6. Press the  
ENTER/YES “R”
  button.
7. “@@.@/##.#” is displayed and the recorded contents are dis-
played.
@@.@ : Indicates the Iop value labeled on the pick-up.
##.#
: Indicates the Iop value after adjustment.
8. Press the  
REPEAT “R”
  button to complete. “Initialize” will
be displayed and release the MD test mode.
WHEN MEMORY NG IS DISPLAYED
If the nonvolatile memory data is abnormal, “E001 MEMORY NG”
will be displayed so that the MD deck does not continue opera-
tions. In this case, set the test mode promptly and perform the
following procedure.
Procedure:
1. Enter the MD test mode.
2. Normally a message for selecting the test mode will be displayed.
However if the nonvolatile memory is abnormal, the following
will be displayed “INIT EEP?”.
3. Press the
x
  and 
MD 
Z  buttons simultaneously.
4. Press the  
“R”
  or
  >
 “R”
  button to display “MDM-7B4M”.
5. Press the
ENTER/YES “R”
button. If the nonvolatile memory is
successfully overwritten, the normal MD test mode will be set
and a message to select the MD test mode will be displayed.
30
HCD-C5
CHECKS PRIOR TO PARTS REPLACEMENT AND ADJUSTMENTS IN MD
Before performing repairs, perform the following checks to determine the faulty locations up to a certain extent.
Details of the procedures are described in “5 Electrical Adjustments”.
• 0.9 mW power
Specified value : figure1
• 7.0 mW power
Specified value : figure2
Iop (at 7.0mW)
• Labeled on the optical pick-up
Iop value 
±
 10mA
• Unsatisfactory if displayed as “NG: XXXX”
(X is an arbitrary number)
• Unsatisfactory if displayed as “T=@@ (##) [NG]”
(@@, ## are both arbitrary numbers)
Laser power check
(6-2 : See page 37)
Auto check
(6-4 : See page 38)
Temperature
compensation
offset check
(6-1 : See page 37)
Criteria for Determination
(Unsatisfactory if specified value is not satisfied)
• Clean the optical pick-up
• Adjust again
• Replace the optical pick-up
• Replace the optical pick-up
• Replace the optical pick-up
• Check for disconnection of the circuits around D101
(BD (MD) board)
• Check the signals around IC101, IC151, CN102, CN103
(BD (MD) board)
Measure if unsatisfactory
Note:
The criteria for determination above is intended merely to determine if satisfactory or not, and does not serve as the specified value for adjust-
ments.
When performing adjustments, use the specified values for adjustments.
Figure1:
Figure2:
RETRY CAUSE DISPLAY MODE IN MD
• In this test mode, the causes for retry of the unit during recording can be displayed on the fluorescent indicator tube. During
playback, the “track mode” for obtaining track information will be set.
This is useful for locating the faulty part of the unit.
• The following will be displayed :
During recording and stop : Retry cause, number of retries, and number of retry errors.
During playback
: Information such as type of disc played, part played, copyright.
These are displayed in hexadecimal.
Precedure:
1. Load a recordable disc whose contents can be erased into the unit.
2. Press the  
MENU/NO “R”  
button. When “Edit Menu” is displayed on the fluorescent indicator tube, press the
“R”
or  > 
“R”
  button to display “All Erase?”.
3. Press the  
ENTER/YES “R”
  button.
4. When “All Erase??” is displayed on the fluorescent indicator tube.
5. Press the  
ENTER/YES “R”
  button to display “Complete!”.
6. Press the  
REC/REC IT
  button to start recording. Then press the  u
 
  button and start recording. If recording cannot be performed,
press the  
FUNCTION 
z  button and set a different function.
7. Press three buttons of
  VOL -  
,
  
u
  
and
  CD SYNC HIGH  
simultaneously to enter the retry cause display mode.
8. To check the “track mode”, press the
  
u
  
button to start playback.
9. To release this mode, press the  ?/1  button to turn the power off. When “TOC” goes off, disconnect the power plug from the
outlet.
If the test mode cannot be released, refer to “Factory Preset” on page 24.
SPECIFIED VALUE
KMS-260B
KMS-260E
6.8 to 7.2 mW
7.0 to 7.5 mW
SPECIFIED VALUE
KMS-260B
KMS-260E
0.85 to 0.91 mW
0.90 to 0.96 mW
31
HCD-C5
Reading the Retry Cause Display
Reading the Display:
Convert the hexadecimal display into binary display. If more than two causes, they will be added.
Example
When 42 is displayed:
Higher bit : 4 = 0100 
t b6
Lower bit : 2 = 0010 
t b1
In this case, the retry cause is combined of “CLV unlock” and “ader5”.
When A2 is displayed:
Higher bit : A = 1010 
t b7 + b5
Lower bit : 2 = 0010 
t b1
The retry cause in this case is combined of “Access fault”, “IVR rec error”, and “ader5”.
Hexadecimal
01
02
04
08
10
20
40
80
Hexadecimal
Bit
Binary
Occurring conditions
When track jump (shock) is detected
When ADER was counted more than five times
continuously
When ADIP address is not continuous
When DIN unlock is detected
When not in focus
When ABCD signal level exceeds the specified range
When CLV is unlocked
When access operation is not performed normally
Cause of Retry
shock
ader5
Discontinuous address
DIN unlock
FCS incorrect
IVR rec erraor
CLV unlock
Access fault
Higher Bits
8
4
2
1
8
4
2
1
b7
b6
b5
b4
b3
b2
b1
b0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
Lower Bits
Fig. 1 Reading the Test Mode Display
(During recording and stop)
RTs@@c##e
**
fluorescent indicator tube
@@ : Cause of retry
##
: Number of retries
**
: Number of retry errors
Fig. 2 Reading the Test Mode Display
(During playback)
@@ ###
** 
$$
fluorescent indicator tube
@@ : Parts No. (name of area named on TOC)
##
: Cluster
**
: Sector
$$
: Track mode (Track information such as
copyright information of each part)
32
HCD-C5
Reading the Display:
Convert the hexadecimal display into binary display. If more than two causes, they will be added.
Example When 84 is displayed:
Higher bit : 8 = 1000 
t b7
Lower bit : 4 = 0100 
t b2
In this case, as b2 and b7 are 1 and others are 0, it can be determined that the retry cause is combined of “Emphasis OFF”, “Monaural”,
“Original”, “Copyright”, and “Write allowed”.
Example When 07 is displayed:
Higher bit : 0 =  0000 
t All 0
Lower bit : 7 = 0111 
t b0 + b1 + b2
In this case, as b0, b1, and b2 are 1 and others are 0, it can be determined that the retry cause is combined of “Emphasis ON”, “Stereo”,
“Original”, “Copyright”, and “Write prohibited”.
Hexadecimal 
t
 Binary Conversion Table
Hexadecimal
Binary
Hexadecimal
Binary
0
0000
8
1000
1
0001
9
1001
2
0010
A
1010
3
0011
B
1011
4
0100
C
1100
5
0101
D
1101
6
0110
E
1110
7
0111
F
1111
Hexadecimal
01
02
04
08
10
20
40
80
Hexadecimal
Bit
Binary
When 0
Emphasis OFF
Monaural
This is 2-bit display. Normally 01.
01:Normal audio. Others:Invalid
Audio (Normal)
Original
Copyright
Write prohibited
Higher Bit
8
4
2
1
8
4
2
1
b7
b6
b5
b4
b3
b2
b1
b0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
Lower Bits
When 1
Emphasis ON
Stereo
Invalid
Digital copy
No copyright
Write allowed
Details
Reading the Retry Cause Display