Sony BDV-L600 / BDV-L800 / BDV-L800M / HBD-L600 / HBD-L800 / HBD-L800M Service Manual ▷ View online
HBD-L600/L800/L800M
29
14. Network (Network Test Diagnosis Screen: Ping)
Ping test for the wired ethernet.
Ping test for the wired ethernet.
Screen 1: Ping Test
Operation:
[
Operation:
[
<
] Select
Ifconfi g test
[
m
]
Ping execution preparation
[RETURN] Returns to the top menu of the service mode
Screen 2: The IP address of the Ping point is set up
(IP address input mode)
When “Ping to :>” is reversed, the [
] button is pressed and IP
is inputted.
Operation:
[
Operation:
[
]
Finish to input
[RETURN] Finish to input
[
[
<
]
Finish to input and Select Ifconfi g Test
[0] to [9]
Input Character sting ‘0-9’
[TIME]
Input Character sting ‘.’
[CLEAR] Backspace
Screen 3: Ping Test Active
When [START] is reversed, the [
When [START] is reversed, the [
] button is pressed and execute
ping.
Operation:
[
Operation:
[
]
Activate ping test
[
M
]
The IP address of the ping point is set up
[RETURN] Returns to the top menu of the service mode
(Screen 1)
Test:
(Screen 2)
Ping
Network
Test: Ifconfig
Ping to :> 192. 168. 200. 13
[ENT] : Release
[RET] : Release
[RET] : Release
(Screen 3)
Network
Ping to : 192. 168. 200. 13
[START]
HELP: [ENT] : Start [UP] [LEFT]
Ping
Ifconfig
Ping To :
[START]
Network
Test: Ifconfig
PING 192. 168. 200. 13 OK!
Ping
15. System Information (System Information Display)
This screen displays system information.
This screen displays system information.
Screen 1: Basic Information
Operation:
[
Operation:
[
,
]
Drive information (delta IOP of a drive is measured)
and wireless device information displayed (go to
Screen 2)
and wireless device information displayed (go to
Screen 2)
[RETURN] Returns to the top menu of the service mode
Screen 2: Drive and Wireless Information Menu
Operation:
[
Operation:
[
<
]
Basic Information displayed (go to Screen 1)
[RETURN] Returns to the top menu of the service mode
When delta IOP is measured, it becomes impossible to use the Ver-
sion Up function.
sion Up function.
Contents List:
Model
Destination
Sequence Number
MAC
IP
IFCON IFCON
Model
Destination
Sequence Number
MAC
IP
IFCON IFCON
Version
Bootloader Bootloader
Version
Host Main
Host Main Version
Host Sub
Host Sub Version
Middleware Middleware
Version
ADSP ADSP
Version
2nd DSP
2nd DSP Version
ILLM HAMON
u-con
Version
IF Model
IF Dest
IF Dest
WLAN module Serial (HBD-L800/L800M only)
WLAN module hw Version (HBD-L800/L800M only)
WLAN module MAC Address (HBD-L800/L800M only)
Drive Firm Revision
CD DIOP
WLAN module hw Version (HBD-L800/L800M only)
WLAN module MAC Address (HBD-L800/L800M only)
Drive Firm Revision
CD DIOP
Delta IOP
DVD DIOP
Delta IOP
BD DIOP
Delta IOP
CD LD TIME
LD Time
DVD LD TIME LD Time
BD LD TIME
BD LD TIME
LD Time
HBD-L600/L800/L800M
30
System Information
Sequence Number :
MAC :
MAC :
Model :
Destination :
Destination :
IP :
IF-con Block0 Version :
Block1 Version :
Bootloader Version :
Host Main Version :
Host Sub Version :
Middleware Version :
ADSP Version :
Host Main Version :
Host Sub Version :
Middleware Version :
ADSP Version :
2nd DSP Version :
IF_MODEL :
ILLM :
IF_DEST :
HELP: [RET] [RIGHT]
(Screen 1)
System Information
DVD DIOP :
BD DIOP :
BD DIOP :
Drive Firm Revision :
CD DIOP :
CD DIOP :
WLAN module MAC Address :
WLAN module Serial :
WLAN module hw Version :
WLAN module hw Version :
CD LD TIME :
DVD LD TIME :
BD LD TIME :
DVD LD TIME :
BD LD TIME :
HELP: [RET] [LEFT]
(Screen 2)
16. Drive
This menu is used to operate the drive using drive-related diagnos-
tic and tools.
This menu is used to operate the drive using drive-related diagnos-
tic and tools.
Screen 1: Selecting items under *Drive
Operation:
[
Operation:
[
<
]/[
,
] Selects the category
[
m
]/[
]
Activate the selected category
[RETURN] Returns to the top menu of the service mode
[1] Drive OP data Write
[2] Servo Parameter Check Menu (Not used)
[3] Servo Signal Check Menu (Not used)
[4] S-Curve Check Menu (Not used)
[5] Readability Check Menu (Not used)
[6] OP Position Check Menu (Not used)
[7] OP Check Menu (Not used)
[8] Load Eject Aging (Not used)
[9] Spindle Control Check Menu (Not used)
[10] FA Test Mode (Not used)
[1] Drive OP data Write
[2] Servo Parameter Check Menu (Not used)
[3] Servo Signal Check Menu (Not used)
[4] S-Curve Check Menu (Not used)
[5] Readability Check Menu (Not used)
[6] OP Position Check Menu (Not used)
[7] OP Check Menu (Not used)
[8] Load Eject Aging (Not used)
[9] Spindle Control Check Menu (Not used)
[10] FA Test Mode (Not used)
Screen 2: To start OP data Write
Operation:
[
Operation:
[
] Starts
Screen 3: Show OP data Write result
Operation:
NG - USB is not fi nd
NG - File (Butada.txt) is not fi nd
OK - OP data write
Operation:
NG - USB is not fi nd
NG - File (Butada.txt) is not fi nd
OK - OP data write
• Drive
Test
For drive operating check. Service is only use Drive OP data write
to rewrite OP data after change of new CPU.
to rewrite OP data after change of new CPU.
Drive
[1] Drive OP data Write
Drive OP data Write
Insert USB StorageDevice ...
Remove DISC and Close tray.
Remove DISC and Close tray.
HELP: [ENT] [RET]
[ENT] Start
(Screen 1)
(Screen 2)
(Screen 3)
HELP: [ENT] [RET]
Drive OP data Write
Insert USB StorageDevice ...
Remove DISC and Close tray.
Remove DISC and Close tray.
NG - USB is not find
NG - File(Butada.txt) is not find
OK - OP data write
NG - File(Butada.txt) is not find
OK - OP data write
[ENT] Start
HBD-L600/L800/L800M
31
CONFIRMATION ITEM
1. Playback Operation Confi rmation
1-1. Test Disc
1. Playback Operation Confi rmation
1-1. Test Disc
Part No.
Description
Layer
J-6090-199-A
BLX-104
Single Layer
J-6090-200-A
BLX-204
Dual Layer
J-2501-307-A
CD (HLX-A1)
J-2501-305-A
HLX-513
Single Layer (NTSC)
J-2501-306-A
HLX-514
Dual Layer (NTSC)
J-6090-077-A
HLX-506
Single Layer (PAL)
J-6090-078-A
HLX-507
Dual Layer (PAL)
Note: Refer to the service manual of BDP-BX1/S350 (Part No. 9-883-
989-1[]) (page 1-3 to 1-14E) for the use of BLX-104/204.
Operation and Display:
1. BLX-104
Procedure:
1. Select
Procedure:
1. Select
23.976Hz/1080p.
2. Play “4.Motion picture”.
3. Check whether player can play back or not.
4. Check each outputs.
Video:
Composite/S
3. Check whether player can play back or not.
4. Check each outputs.
Video:
Composite/S
Video/component/HDMI.
Audio:
Speaker
Speaker
out.
* When 1080/24p monitor is nothing, 1080i (59.94Hz or 50Hz)
can use instead of 1080/24p.
However this is temporary correspondence.
* When the output of HDMI is 1080p, the signal of Composite/S
Video/Component are not output.
It is necessary to lower the output of HDMI to 1080i or less.
2. BLX-204
Procedure:
1. Select 1080i (59.94Hz or 50Hz).
2. Play “4.Motion picture”.
3. Check whether player can play back or not.
Procedure:
1. Select 1080i (59.94Hz or 50Hz).
2. Play “4.Motion picture”.
3. Check whether player can play back or not.
(Check the picture and sound output)
3. CD
(HLX-A1)
Procedure:
Check whether player can play back or not.
(Check the sound output)
Check whether player can play back or not.
(Check the sound output)
4. HLX-513/514 (NTSC), HLX-506/507 (PAL)
Procedure:
1. After displayed Main Menu, select “1.Video Signal”.
2. Play “1.Color bar 100%”.
Procedure:
1. After displayed Main Menu, select “1.Video Signal”.
2. Play “1.Color bar 100%”.
(Check the picture and sound output)
3. Return to Menu.
4. Play “Demonstration 4:3” or “Demonstration 16:9”.
4. Play “Demonstration 4:3” or “Demonstration 16:9”.
(Check the picture and sound output)
1-2. Playback operation confi rmation
Confi rm operation in each signal/output mode of test disc (BLX-
104/204) according to the content of the repair.
Confi rm operation in each signal/output mode of test disc (BLX-
104/204) according to the content of the repair.
Note: “AV Sync.” doesn’t operate.
2. Networking
Confi rmation
Confi rm it according to the following procedure when you confi rm
the connection of the network.
the connection of the network.
Note: Do not execute “Network Connection Diagnostics” of “Network
Settings” of the home menu with only the router connected.
Procedure:
1. Connect the router with the unit with LAN cable.
2. Turn on the power of the unit and the router.
3. Press the [HOME] button on the remote commander, and the
1. Connect the router with the unit with LAN cable.
2. Turn on the power of the unit and the router.
3. Press the [HOME] button on the remote commander, and the
home menu is displayed.
4. Select
“Setup”
“Network Settings” “Internet Settings”,
and press the [
] button on the remote commander.
5. Select “View Networks Status” and press the [
] button on
the remote commander.
6. Confi rm IP address are displayed in “IP Address”, “Subnet
Mask” and “Default Gateway”.
IP Address Setting:
XXXX
Internet Access:
XXXX
Physical Connection:
XXXX
IP Address:
XXX.XXX.XXX.XXX
DNS Settings:
XXXX
MAC Address:
XXX.XXX.XXX.XXX
Primary DNS:
XXX.XXX.XXX.XXX
Secondary DNS:
XXX.XXX.XXX.XXX
Subnet Mask:
XXX.XXX.XXX.XXX
Default Gateway:
XXX.XXX.XXX.XXX
HBD-L600/L800/L800M
32
SECTION 4
ELECTRICAL CHECK
FM AUTO STOP CHECK
generator
SET
+
75
Ω
Procedure :
1. Turn the power on.
2. Input the following signal from Signal Generator to FM an-
1. Turn the power on.
2. Input the following signal from Signal Generator to FM an-
tenna input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation
Deviation
: 75 kHz
Modulation
: 1 kHz
ANT input
: 35 dBu (EMF)
Note: Please use 75 ohm “coaxial cable” to connect SG and the set. You
cannot use video cable for checking.
Please use SG whose output impedance is 75 ohm.
3. Set to FM tuner function and scan the input FM signal with
automatic scanning.
4. Confi rm that input Frequency of A, B and C detected and auto-
matic scanning stops.
The stop of automatic scanning means “The station signal is re-
ceived in good condition”.
Click on the first or last page to see other BDV-L600 / BDV-L800 / BDV-L800M / HBD-L600 / HBD-L800 / HBD-L800M service manuals if exist.