37
LC-60UD20
LC-70UD20
5. Adjustment process mode menu (continued)
16/30
1
LO R 4
xxx
2
LO G 4
xxx
3
LO B 4
xxx
4
LO Y 4
xxx
5
LO R 5
xxx
6
LO G 5
xxx
7
LO B 5
xxx
8
LO Y 5
xxx
9
LO R 6
xxx
10
LO G 6
xxx
11
LO B 6
xxx
12
LO Y 6
xxx
17/30
1
LO R 7
xxx
2
LO G 7
xxx
3
LO B 7
xxx
4
LO Y 7
xxx
5
CTEMP SELECT
CTEMP HI
18/30
1
MODE SELECT 
Factory
2
POS MIN
WB IN
3
POS MID1
xxx
4
POS MID2
xxx
5
POS MID3
xxx
6
POS MID4
xxx
7
POS MID5
xxx
8
POS MID6
xxx
9
POS MID7
xxx
10
POS MAX
xxx
19/30
1
CD MIN
xxx
2
CD MID1
xxx
3
CD MID2
xxx
4
CD MID3
xxx
5
CD MID4
xxx
6
CD MID5
xxx
7
CD MID6
xxx
8
CD MID7
xxx
9
CD MAX
xxx
20/30
1
CALC
OFF
2
RESET
OFF
3
VAL1
xxx
4
VAL2
xxx
5
VAL3
xxx
6
VAL4
xxx
7
VAL5
xxx
8
VAL6
xxx
9
VAL7
xxx
10
GAMMA ADJ TEMP
xxx
21/30
1
MONITOR TIME OUT
ON
Monitor and the main communication time-out setting
2
MONITOR MAX TEMP
xxx
MONITOR MAX temperature setting
3
MONITOR EEP READ / WRITE
WRITE
MONITOR EEPROM READ/WRITE Setting/execution
4
MONITOR EEP ADR
0x  0
MONITOR EEPROM arbitrary addressing
5
MONITOR EEP DATA
0x  0
MONITOR EEPROM arbitrary data specification
22/30
1
LCD TEST PATTERN
Pattern with built-in LCD controller display
2
LCD TEST PATTERN1
OFF
3
LCD TEST PATTERN2
OFF
4
LCD TEST PATTERN3
NOT SUPPORT
5
LCD TEST PATTERN4
NOT SUPPORT
23/30
1
BOARD
2
LVM
3
LSE1(3D)
4
LSE1(2D)
5
LSE2(2D)
6
FRC MASTER FW
7
FRC SLAVE FW
8
TCON(2D MPD OFF MASTER)]
9
TCON(3D MASTER)
38
LC-60UD20
LC-70UD20
5. Adjustment process mode menu (continued)
24/30
1
3DHDMI FPGA Version
xxxxx
2
2D䊻3D FPGA Version
xxxxx
3
3D LED BRIGHTNESS
xxxxx
4
3D IR EMITTER CONTROL
ON
25/30
1
CROSSTALK ADJ MODE
Enter
2
CROSSTALK TH1
3
CROSSTALK TH2
4
CROSSTALK TH3
5
CROSSTALK TH4
6
CROSSTALK GAIN1
7
CROSSTALK GAIN2
8
CROSSTALK GAIN3
26/30
1
WIFI SSID 2.4GHz
xxxxx
2
WIFI SSID 5  GHz
xxxxx
3
WIFI RSSI 2.4GHz
xxxxx
4
WIFI RSSI 5  GHz
xxxxx
5
WIFI TIME 5 GHz
xxxxx
6
WIFI RSSI TEST
xxxxx
7
WIFI RSSI RESULT
xxxxx
27/30
1
READ/WRITE
READ
Read/Write
2
SLAVE/ADDRESS
SLAVE0
Slave address
3
REGISTER ADDRESS
0x 0
0x 0
Register address
4
WRITE DATA
0x 0
0x 0
Writing data
5
READ DATA
0x 0
0x 0
Reading data
28/30
1
RF AGC BG
xx
RF-AGC BG adjustment execution
2
RF AGC DK
xx
RF-AGC DKG adjustment execution
3
RF AGC I
xx
RF-AGC I adjustment execution
4
RF AGC L/L'
xx
RF-AGC L/L' adjustment execution
5
CI+ AUTHENTICATION
xx
29/30
1
ERROR STANDBY CAUSE1
NO RECORD
ERROR STANDBY CAUSE
2
ERROR STANDBY CAUSE2
NO RECORD
3
ERROR STANDBY CAUSE3
NO RECORD
4
ERROR STANDBY CAUSE4
NO RECORD
5
ERROR STANDBY CAUSE5
NO RECORD
6
STANDBY CAUSE RESET
OFF
Reset stand by cause.
7
USB BACKUP
Enter
8
USB RESTORE
Enter
30/30
1
EEP SAVE
OFF
Writing setting values to EEPROM.
2
EEP RECOVER
OFF
Reading setting values from EEPROM.
3
MONITOR ERROR CAUSE RESET
OFF
Reset of monitor error cause
4
MODEL NAME
UD20E
MODEL NAME
5
PANEL SIZE
xx
Panel size setting.
6
VERUP FLAG ENABLE
Enter
Verup Flag
7
PANEL LIMIT
ON
PANEL LIMIT
8
PANEL RANGE LIMIT
xxx
PANEL RANGE LIMIT
9
SHORT CHECK MODE
Enter
Check LED Back light
10
SHORT CHECK CURRENT
xx
11
PRODUCT EEP ADR
0x 0
Don't touch when serving (for producer of factory)
12
PRODUCT EEP DATA
0x 0
Don't touch when serving (for producer of factory)
13
PRODUCT FACTORY
xxx
Don't touch when serving (for producer of factory)
14
TEST NETWORK UPDATE
NO
39
LC-60UD20
LC-70UD20
6. Special features
6.1. NORMAL STANDBY CAUSE (Page 1/30)
Display of a cause (code) of the last standby.
The cause of the last standby is recorded in EEPROM whenever it is possible.
Checking this code will be useful in fi nding a problem when you repair the troubled set.
6.2. EEP SAVE (Page 30/30)
Storage of EEP adjustment value.
6.3. EEP RECOVER (Page 30/30)    
Retrieval of EEP adjustment value from storage area.
6.4. MONITOR ERR CAUSE (Page 1/30)
Display of a cause (code) of Error from Monitor microcomputer. 
The cause of Error is recorded in EEPROM whenever it is possible.
Checking this code will be useful in fi nding a problem when you repair the troubled set.
c
This displays Error code and time when the error occurred. 
The latest error is displayed  on “ 1)”
The error that happens ahead of “1)” is displayed on “2)”. 
d
The character depends on the way how to acquire Time Information.
 T: Time is acquired from digital broadcasting.
This doesn’t contain “Time offset” which is considered a time difference and Daylight-Saving Time, etc....
U: Time is acquired from analog broadcasting (teletext).
B: Accumulation time of Backlight.
In the case that Time information cannot be acquired, “B” is displayed 
.
Example)   In this example, it is shown that the error occurred 3 times.
1) 16 T07/01/01 12:03
Error code: 16 (lamp error)     
 
 
 
 It is latest Error.
Time : 07/01/01 12:03 
 
 
 
 
 Time is acquired from digital broadcasting.
 
 
 
 
 
 
 
 
 Time is UTC which doesn’t have Time offset.
2) 16 U01/01/01 04:07
Error code: 16 (lamp error)    
 
 
 
 It is Error that happens ahead of “1)”. 
Time : 07/01/01 04:07 
 
 
 
 
 Time is acquired from analogue broadcasting.
3) 16 B00000004:11
Error code: 16 (lamp error)    
 
 
 
  It is Error that happens ahead of “2)”. 
Accumulation time : It is displayed that 4:11 have passed after Backlight driving.
4) 00 000000000No error (“00” shows that the error is not occurred.)
7. Lamp Error detection
7.1. Function
This LCD color TV set incorporates a Lamp error detection feature that automatically turns off the power for safety 
under  abnormal lamp or lamp circuit conditions. If by any chance anything is wrong with the lamp or lamp circuit or if 
the lamp error detection feature is activated for some reason, the following will result:
1) The power is interrupted in about 500ms after it is turned on.     
(A central icon on the front of the TV fl ash on and off. : ON for 400ms and OFF for 1600ms.).
2) If the above phenomenon 1) occurs 5 times, it becomes impossible to turn on the power.  
(A central icon keep fl ashing on/off.)
7.2. Measures
1) Set the lamp error detection to OFF.
Enter the adjustment process mode, referring to “2. Entering and exiting the adjustment process mode.”
The adjustment process mode can ignore “5 times count”, so if the above phenomenon 1) occurs 1~4 times, the 
lamp will go out.
If Lamp Error detection pin [22pin of PD : P3801 / 19pin of IC2002 ] is “High” by a trouble with the lamp and lamp 
circuit, it can boot-up by the adjustment process mode.
Please execute  “Lamp Error detection off-mode”.
Unplug the AC power cord of running TV set to force off the power.
While holding down the “VOL (+)” and “P ( 
s
 )” keys on the set at once, plug in the AC power cord to turn on 
the power.
After a central icon fl ash off, separate the fi ngers from key on the set .
Then, you can check the operation to see if the lamp and lamp circuit are in trouble.
If you fail boot-up, retry the procedure.
40
LC-60UD20
LC-70UD20
2) Reseting the lamp error count
After the lamp and lamp circuit are improved from a trouble, reset the lamp error count. 
(Because the power cannot be turned on, if a lamp error is detected 5 consecutive times)
1) Enter the adjustment process mode, referring to “2. Entering and exiting the adjustment process mode.”
2) Using the cursor (▲/▼) key, move to the cursor to [LAMP ERROR RESET], line 8 on adjustment process mode 
service page 2. 
3) With the cursor (◄/►) keys, select the [LAMP ERROR RESET] value. 
Finally press the cursor (OK), the count is reset. 
Check LAMP ERROR Count on adjustment process mode Page 2.
8. Public Mode
8.1. Starting the Public Mode
1) Method of needing password:
a) While holding down the “INPUT” and “Volume UP” keys on the set at once, plug in the AC power cord to turn 
on the power.
b) Display the Password input screen.
After a while, value of Enter password appears on the screen.
Operation procedure
• 
The initial input position is the digit at the left end.
• 
For the numeric keys “0” to “9” of R/C, key input is accepted. 
Input of the other keys is prohibited
• 
Change “ –” to “ * ” by inputting the numeric key at the input position, and shift the input position rightward one 
digit.
• 
When three digits are completely input, the Password is judged.
c) Check the Password by inputting three digits.
If the Password “0” “2” “7”, it shifts to the PUBLIC Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
㻢㻚㻌㻿 㼑㼏㼕㼍㼘㻌㼒㼑㼍㼠㼡㼞㼑㼟
㻣㻚㻌㻸㼍㼙 㻌㻱㼞㼞㼛㼞㻌㼐㼑㼠㼑㼏㼠㼕㼛㼚
䇾㻸㼍㼙㼜㻌㻱㼞㼞㼛㼞㻌㼐㼑㼠㼑㼏㼠㼕㼛㼚㻌㼛㼒㼒㻙㼙㼛㼐㼑䇿㻚
䚷䚷㼀㼍㼎㼘㼑㻌㼛㼒㻌㼏㼛㼚㼠㼑㼚㼠㼟㻌㼛㼒㻌㼍㼐㼖㼡㼟㼠㼙㼑㼚㼠㻌㼜㼞㼛㼏㼑㼟㼟㻌㼙㼛㼐㼑㻌㻼㼍㼓㼑㻌㻞
㻵㻺㻰㼁㻿㼀㻾㼅㻌㻵㻺㻵㼀㻌
㻱㼚㼠㼑㼞
㻵㻺㻰㼁㻿㼀㻾㼅㻌㻵㻺㻵㼀㻔㻙㻼㼡㼎㼘㼕㼏㼘㻕㻌
㻻㻲㻲
㻼㼡㼎㼘㼕㼏㻌㻹㻻㻰㻱㻌
㻻㻲㻲
㻯㼑㼚㼠㼑㼞㻌㻭㼏㼡㼠㼕㼙㼑㻌
䞉䞉䞉
㻾㻱㻿㻱㼀㻌
㻻㻲㻲
㻮㼍㼏㼗㼘㼕㼓㼔㼠㻌㻭㼏㼡㼠㼕㼙㼑
䞉䞉䞉
㻾㻱㻿㻱㼀㻌
㻻㻲㻲
㻸㻭㻹㻼㻌㻱㻾㻾㻻㻾㻌㻾㻱㻿㻱㼀㻌
㻻㻲㻲
㻾㼑㼟㼑㼠㼠㼕㼚㼓㻌㼠㼛㻌㻎㻜㻎
㻭㻰㻶㻌㻼㻭㻾㻭㻹㻌㻿㻱㼀㻌
㻱㼚㼠㼑㼞
㼂㻵㻯㻌㼄㻼㻻㻿㻌
㼂㻵㻯㻌㼅㻼㻻㻿
㼂㻵㻯㻌㻿㻵㻳㻺㻭㻸㻌㼀㼅㻼㻱㻌
㻹㻭㻵㻺
㼂㻵㻯㻌㻾㻱㻭㻰㻌
㻻㻲㻲
Table of contents of adjustment process mode Page 2
㻤㻚㻌㻼㼡㼎㼘㼕㼏㻌㻹㼛㼐㼑
㻱㼚㼠㼑㼞 㼜㼍㼟㼟㼣㼛㼞㼐
㸫 㸫 㸫
㻱㼚㼠㼑㼞 㼜㼍㼟㼟㼣㼛㼞㼐
㸨 㸫 㸫
㻱㼚㼠㼑㼞 㼜㼍㼟㼟㼣㼛㼞㼐
㸨 㸨 㸨
Page of 94
Display

Click on the first or last page to see other LC-70UD20KN (serv.man4) service manuals if exist.