DOWNLOAD Sharp LC-28HM2E (serv.man2) Service Manual ↓ Size: 707.1 KB | Pages: 48 in PDF or view online for FREE

Model
LC-28HM2E (serv.man2)
Pages
48
Size
707.1 KB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / text
File
lc-28hm2e-sm2.pdf
Date

Sharp LC-28HM2E (serv.man2) Service Manual ▷ View online

17
LC-28HM2
AN-28SP2
4
Process adjustment mode for display only
[Procedure]
Separate the display from the AVC center.
While pressing [BRIGHTNESS] and [VOL–] buttons simultaneously, switch on the power.
[Contents]
Various monitor side adjustments can be made manually.
(1) Lamp error reset (Done automatically with presetting)
Set 0F 00 0 in the 1st line, and then set 1 into the least significant bit. Upon this setting, the “lamp error” is
reset.
(After reset, 1 in the least significant bit will not become 0 automatically.)
After reset, switch off the power once and confirm that the system can be restarted in normal mode.
(2) Monitor G/A test pattern reset
Set 00 10 00 in the 3rd line, and then set 1 in the 4th line. Upon this setting, the blue screen appears. Thus
the test pattern in the monitor process adjustment is reset.
(After reset, the fourth line will not become 0 automatically.)
After reset, switch off the power once and confirm that the system can be restarted in normal mode.
3. How to terminate special modes
1
Process adjustment mode:
Press [PROCESS ADJUSTMENT] button of the remote controller, or switch off the power.
2
Inspection process mode:
Turn P1L6 “SIGNAL INFO” to “OFF”, or switch off the power.
3
Presetting:
Upon completion, the system automatically moves to the process adjustment mode.
4
Process adjustment mode for display only:
Switch off the power.
18
LC-28HM2
AN-28SP2
LIST OF ADJUSTMENT ITEMS
P
L
Item
Initial setting
Description
1
1
CENTER VERSION
Center side microcomputer version
2
MONITOR VERSION
Monitor side microcomputer version
3
MODEL SELECT
Model selection for each destination
4
CENTER ACUTIME
Center side accumulated operation time
5
MONITOR ACUTIME
Monitor side accumulated operation time
6
SIGNAL INFO
Inspection mode switch
7
LAMP NG CHECK
Times of lamp error detection
8
GAMMA LEVEL BRIGHT
16
Gamma level for brightness adjustment
9
GAMMA LEVEL CONTRAST
232
Gamma level for contrast adjustment
10
GAMMA LEVEL COLOR
185
Gamma level for color adjustment
11
GAMMA SELECT SW
NORMAL
Gamma table mode selection switch
2
1
+BADJ CENTER
Center side +B adjustment
2
+BADJ MONITOR
Monitor side +B adjustment
3
COMMON BIAS
Common bias adjustment
4
CN358 BRIGHT
133
Composite NTSC 3.58 black level setting
5
_BR SET FROM N358
Copy of black level adjustment value
6
CN358 CONTRAST
70
Composite NTSC 3.58 contrast setting
7
CN358 R DRIVE
56
Composite NTSC 3.58 red gain setting
8
CN358 B DRIVE
72
Composite NTSC 3.58 blue gain setting
9
CN358 COLOR
70
Composite NTSC 3.58 color density setting
10
CN358 TINT
70
Composite NTSC 3.58 tint setting
11
CN358 SHARPNESS
64
Composite NTSC 3.58 sharpness setting
12
CN358 APACONPEAK
1
Composite NTSC 3.58 apaconpeak setting
13
CN358 YNR LEVEL
NORMAL
Composite NTSC 3.58 YNR level setting
14
CN358 CDE
3
Composite NTSC 3.58 CDE level setting
15
CN358 SHR TRACKING
2
Composite NTSC 3.58 sharpness correction setting
16
CN358 C TRAP
0
Composite NTSC 3.58 C trap setting
17
CN358 H POS
0
Composite NTSC 3.58 horizontal position setting
3
1
C PAL BRIGHT
133
Composite PAL black level setting
2
C PAL CONTRAST
71
Composite PAL contrast setting
3
C PAL R DRIVE
58
Composite PAL red gain setting
4
C PAL B DRIVE
70
Composite PAL blue gain setting
5
C PAL COLOR
85
Composite PAL color density setting
6
C PAL TINT
60
Composite PAL tint setting
7
C PAL SHARPNESS
48
Composite PAL sharpness setting
8
C PAL APACONPEAK
3
Composite PAL apaconpeak setting
9
C PAL YNR LEVEL
MIN
Composite PAL YNR level setting
10
C PAL CDE
3
Composite PAL CDE level setting
11
C PAL SHR TRACKING
2
Composite PAL sharpness correction setting
12
C PAL C TRAP
0
Composite PAL C trap setting
13
C PAL H POS
1
Composite PAL horizontal position setting
4
1
BELL F0
113
SECAM bell filter setting
2
C SECAM BRIGHT
131
Composite SECAM black level setting
3
C SECAM CONTRAST
72
Composite SECAM contrast setting
4
C SECAM R DRIVE
62
Composite SECAM red gain setting
5
C SECAM B DRIVE
72
Composite SECAM blue gain setting
6
C SECAM COLOR
33
Composite SECAM color density setting
7
C SECAM TINT
64
Composite SECAM tint setting
8
C SECAM SHARPNESS
48
Composite SECAM sharpness setting
9
C SECAM APACONPEAK
3
Composite SECAM apaconpeak setting
10
C SECAM YNR LEVEL
OFF
Composite SECAM YNR level setting
11
C SECAM CDE
3
Composite SECAM CDE level setting
19
LC-28HM2
AN-28SP2
P
L
Item
Initial setting
Description
4
12
C SECAM SHR TRACKING
0
Composite SECAM sharpness correction setting
13
C SECAM C TRAP
1
Composite SECAM C trap setting
14
C SECAM H POS
4
Composite SECAM horizontal position setting
15
B-Y BLACK LEVEL
SECAM B-Y black level setting
16
R-Y BLACK LEVEL
SECAM R-Y black level setting
5
1
COMP 15/60 BRIGHT
130
Component 15k/60Hz black level setting
2
COMP 15/60 CONTRAST
81
Component 15k/60Hz contrast setting
3
COMP 15/60 R DRIVE
57
Component 15k/60Hz red gain setting
4
COMP 15/60 B DRIVE
73
Component 15k/60Hz blue gain setting
5
COMP 15/60 COLOR
36
Component 15k/60Hz color density setting
6
COMP 15/60 TINT
64
Component 15k/60Hz tint setting
7
COMP 15/60 SHARPNESS
48
Component 15k/60Hz sharpness setting
8
COMP 15/60 APACONPEAK
1
Component 15k/60Hz apaconpeak setting
9
COMP 15/60 YNR LEVEL
NORMAL
Component 15k/60Hz YNR level setting
10
COMP 15/60 CDE
2
Component 15k/60Hz CDE level setting
11
COMP 15/60 SHR TRACKING
0
Component 15k/60Hz sharpness correction setting
12
COMP 15/60 H POS
7
Component 15k/60Hz horizontal position setting
13
DATA COPY
Data copy
6
1
MONITOR CORRECT ALL
Monitor correction RGB
2
MONITOR CORRECT R
Monitor correction R
3
MONITOR CORRECT G
Monitor correction G
4
MONITOR CORRECT B
Monitor correction B
5
CEENT EEP RST S/C ONLY
EEPROM reset in Sharp Corporation control area only
6
MONITOR EEP RST
Monitor side EEPROM reset
7
UPDATE CENTER PROGRRAM
Start updating the center side program
8
UPDATE MONITOR PROGRAM
Start updating the monitor side program
9
G/A TESTPAT
G/A test pattern
10
G/A MASK SW
G/A masking
11
I
2
C CHANNEL
I
2
C device control
12
I
2
C SLAVE ADDRESS
I
2
C device control
13
I
2
C SUB ADDRRESS
I
2
C device control
14
I
2
C DATA
I
2
C device control
7
1
CENTER ACUTIME RESET
Resetting center side accumulated operation time
2
MONITOR ACUTIME RESET
Resetting monitor side accumulated operation time
3
LOUDNESS
4
DIP SW
5
SPEAKER ENABLE
Speaker mute control
6
LAMP NG CHECK SW
7
AUTOWIDE SPEED
Auto-wide speed setting
8
NR-ON/OFF
9
TA1298 YNR VIDEO
10
UPD64082 YNR
UPD64082YNR intensity setting
11
NOISE LEVEL
12
DECORDER TINT
13
NR LEVEL ADD
14
INR SW
15
INR LEVEL
8
1
COMP 15/50 BRIGHT
130
Component 15k/50Hz black level setting
2
COMP 15/50 CONTRAST
81
Component 15k/50Hz contrast setting
3
COMP 15/50 R DRIVE
57
Component 15k/50Hz red gain setting
4
COMP 15/50 B DRIVE
73
Component 15k/50Hz blue gain setting
20
LC-28HM2
AN-28SP2
P
L
Item
Initial setting
Description
8
5
COMP 15/50 COLOR
36
Component 15k/50Hz color density setting
6
COMP 15/50 TINT
64
Component 15k/50Hz tint setting
7
COMP 15/50 SHARNESS
48
Component 15k/50Hz sharpness setting
8
COMP 15/50 APACONPEAK
1
Component 15k/50Hz apaconpeak setting
9
COMP 15/50 YNR LEVEL
NORMAL
Component 15k/50Hz YNR level setting
10
COMP 15/50 CDE
2
Component 15k/50Hz CDE level setting
11
COMP 15/50 SHR TRACKING
0
Component 15k/50Hz sharpness correction setting
12
COMP 15/50 H POS
7
Component 15k/50Hz horizontal position setting
9
1
COMP 31K APACONPEAK
5
Component 31k apaconpeak setting
2
COMP 33K APACONPEAK
5
Component 33k apaconpeak setting
3
COMP 45K APACONPEAK
5
Component 45k apaconpeak setting
4
COMP 31K YNR LEVEL
MIN
Component 31k YNR level setting
5
COMP 33K YNR LEVEL
MIN
Component 33k YNR level setting
6
COMP 45K YNR LEVEL
MIN
Component 45k YNR level setting
7
COMP 31KHZ CDE
0
Component 31k CDE level setting
8
COMP 33KHZ CDE
0
Component 33k CDE level setting
9
COMP 45KHZ CDE
0
Component 45k CDE level setting
10
COMP 31K SHR TRACKING
1
Component 31k sharpness correction level setting
11
COMP 33K SHR TRACKING
1
Component 33k sharpness correction level setting
12
COMP 45K SHR TRACKING
1
Component 45k sharpness correction level setting
13
COMP 31K H POS
1
Component 31k horizontal position setting
14
COMP 33K H POS
1
Component 33k horizontal position setting
15
COMP 45K H POS
1
Component 45k horizontal position setting
10
1
CN443 BRIGHT
133
Composite NTSC 4.43 black level setting
2
CN443 CONTRAST
71
Composite NTSC 4.43 contrast setting
3
CN443 R DRIVE
58
Composite NTSC 4.43 red gain setting
4
CN443 B DRIVE
70
Composite NTSC 4.43 blue gain setting
5
CN443 COLOR
85
Composite NTSC 4.43 color density setting
6
CN443 TINT
52
Composite NTSC 4.43 tint setting
7
CN443 SHARPNESS
64
Composite NTSC 4.43 sharpness setting
8
CN443 APACONPEAK
3
Composite NTSC 4.43 apaconpeak setting
9
CN443 YNR LEVEL
NORMAL
Composite NTSC 4.43 YNR level setting
10
CN443 CDE
3
Composite NTSC 4.43 CDE level setting
11
CN443 SHR TRACKING
2
Composite NTSC 4.43 sharpness correction setting
12
CN443 C TRAP
1
Composite NTSC 4.43 C trap setting
13
CN443 H POS
1
Composite NTSC 4.43 horizontal position setting
11
1
C PAL-M BRIGHT
133
Composite PAL-M black level setting
2
C PAL-M CONTRAST
71
Composite PAL-M contrast setting
3
C PAL-M R DRIVE
58
Composite PAL-M red gain setting
4
C PAL-M B DRIVE
70
Composite PAL-M blue gain setting
5
C PAL-M COLOR
85
Composite PAL-M color density setting
6
C PAL-M TINT
58
Composite PAL-M tint setting
7
C PAL-M SHARPNESS
16
Composite PAL-M sharpness setting
8
C PAL-M APACONPEAK
2
Composite PAL-M apaconpeak setting
9
C PAL-M YNR LEVEL
LOW
Composite PAL-M YNR level setting
10
C PAL-M CDE
3
Composite PAL-M CDE level setting
11
C PAL-M SHR TRACKING
2
Composite PAL-M sharpness correction setting
12
C PAL-M C TRAP
0
Composite PAL-M C trap setting
13
C PAL-M H POS
0
Composite PAL-M horizontal position setting
12
1
C PAL-60 BRIGHT
133
Composite PAL-60 black level setting
2
C PAL-60 CONTRAST
70
Composite PAL-60 contrast setting
Page of 48
Display