DOWNLOAD Sharp XV-Z3000 Service Manual ↓ Size: 25.15 MB | Pages: 120 in PDF or view online for FREE

Model
XV-Z3000
Pages
120
Size
25.15 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Complete Service Manual
File
xv-z3000.pdf
Date

Sharp XV-Z3000 Service Manual ▷ View online

XV-Z3000
DT-500
In the interests of user-safety (Required by safety regulations in some countries) the set should be re-
stored to its original condition and only parts identical to those specified should be used.
MODELS
XV-Z3000
DT-500
PROJECTOR
SERVICE MANUAL
S26R9XV-Z3000
CONTENTS
Page
Page
• SPECIFICATIONS ............................................ 2
• IMPORTANT SERVICE SAFETY
NOTES (for USA) .............................................. 3
• NOTE TO SERVICE PERSONNEL .................. 5
• OPERATION MANUAL ..................................... 9
• DIMENSIONS ................................................. 14
• REMOVING OF MAJOR PARTS .................... 15
• RESETTING THE TOTAL LAMP TIMER ........ 18
• THE OPTICAL UNIT OUTLINE ....................... 20
• ELECTRICAL ADJUSTMENT ......................... 22
• TROUBLE SHOOTING TABLE ....................... 28
• BLOCK DIAGRAM .......................................... 40
• OVERALL WIRING DIAGRAM ....................... 42
• DESCRIPTION OF SCHEMATIC DIAGRAM .. 44
• WAVEFORMS ................................................. 45
• SCHEMATIC DIAGRAM ................................. 46
• PRINTED WIRING BOARD ASSEMBLIES .... 80
• PARTS LIST
Ë ELECTRICAL PARTS ............................... 101
Ë CABINET AND MECHANICAL PARTS .... 113
Ë  ACCESSORIES PARTS ........................... 117
Ë  PACKING PARTS..................................... 117
• PACKING OF THE SET ................................ 118
2
XV-Z3000
DT-500
SPECIFICATIONS
Projector
XV-Z3000, DT-500
NTSC3.58/NTSC4.43/PAL/PAL-M/PAL-N/PAL-60/SECAM/DTV480I/DTV480P/
DTV540P/DTV576I/DTV576P/DTV720P/DTV1035I/DTV1080I/DTV1080I-50
Single Chip Digital Micromirror Device
TM
 (DMD
TM
) by Texas Instruments
Panel size: 0.65", 1chip DMD
Drive method: Digital Light Processing (DLP™)
No. of dots: 983,040 dots (1280 [H] 
 768 [V])
1–1.15
✕ zoom lens, F2.4–2.6, f = 19.0–21.9 mm
275 W DC lamp
RCA connector
Y: 1.0 Vp-p, sync negative, 75 Ω terminated
P
B
 (C
B
): 0.7 Vp-p, 75 Ω terminated
P
R
 (C
R
): 0.7 Vp-p, 75 Ω terminated
4-pin mini DIN connector
Y (luminance signal): 1.0 Vp-p, sync negative, 75 Ω terminated
C (chrominance signal): Burst 0.286 Vp-p, 75 Ω terminated
RCA connector: VIDEO, composite video, 1.0 Vp-p, sync negative, 75 Ω
terminated
15-pin mini D-sub connector
RGB separate/sync on green type analog input: 0–0.7 Vp-p, positive, 75 Ω terminated
HORIZONTAL SYNC. SIGNAL: TTL level (positive/negative)
VERTICAL SYNC. SIGNAL: Same as above
HDMI terminal (video signal only)
720 TV lines (DTV720P)
45–85 Hz
15–70 kHz
12–85 MHz
9-pin mini DIN connector
Power jack: DC 12V output (only XV-Z3000)
AC 100–240 V
3.7 A
50/60 Hz
355 W (Lamp Setting  "Bright")/
310 W (Lamp Setting  "Eco + Quiet") with AC 100 V
340 W (Lamp Setting  "Bright")/
300 W (Lamp Setting  "Eco + Quiet") with AC 240 V
4 W (AC 100 V)   5  W (AC 240 V)*
1
1,335 BTU/hour (Lamp Setting  "Bright")/
1,165 BTU/hour (Lamp Setting  "Eco + Quiet") with AC 100 V
1,280 BTU/hour (Lamp Setting  "Bright")/
1,130 BTU/hour (Lamp Setting  "Eco + Quiet") with AC 240 V
41°F to 95°F (+5°C to +35°C)
-4°F to 140°F ( 20°C to +60°C)
Plastic
38 kHz
12 
13
/
32
 4 
19
/
64
 11 
1
/
32
 (315 (W) 
 109 (H) 
 280 (D) mm) (main body only)
12 
13
/
32
 4 
47
/
64
 11 
37
/
64
 (315 (W) 
 120 (H) 
 294 (D) mm) (including adjust-
ment foot and projecting parts)
8.8 lbs. (4.0 kg)
Remote control, Power cord, 21 pin RCA conversion adaptor (XV-Z3000E/K), 
Video cable (XV-Z3000E/K), Operation manual
Product type
Model
Video system
Display method
DMD panel
Lens
Projection lamp
Component input signal
(INPUT1/2)
S-video input signal
(INPUT 3)
Video input signal
(INPUT 4)
Computer RGB/
Component input signal
(INPUT 5)
HDMI input signal
(INPUT 6)
Horizontal resolution
Vertical frequency
Horizontal frequency
Pixel clock
RS-232C terminal
TRIGGER terminal
Rated voltage
Input current
Rated frequency
Power consumption
Power consumption (standby)
Heat dissipation
Operating temperature
Storage temperature
Cabinet
I/R carrier frequency
Dimensions (approx.)
Weight (approx.)
Replacement parts
*
1
 When STANDBY Mode is set to "Eco"
As a part of policy of continuous improvement, SHARP reserves the right to make design and
specification changes for product improvement without prior notice. The performance specifica-
tion figures indicated are nominal values of production units. There may be some deviations from
these values in individual units.
3
XV-Z3000
DT-500
IMPORTANT SERVICE SAFETY NOTES (for USA)
Ë Service work should be performed only by qualified service technicians who are
thoroughly familiar with all safety checks and servicing guidelines as follows:
WARNING
1. For continued safety,  no modification of any circuit
should be attempted.
2. Disconnect AC power before servicing.
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
SAFETY NOTICE
Many electrical  and  mechanical parts in DMD™
Projector have special safety-related characteristics.
These characteristics are often not evident from visual
inspection, nor can protection afforded by them be
necessarily increased by using replacement components
rated for higher voltage, wattage, etc.
Replacement parts which have these special safety
characteristics are identified in this manual; electrical
DVM
AC SCALE
1.5k ohm
10W
TO EXPOSED
METAL PARTS
CONNECT TO
KNOWN EARTH
GROUND
0.15 µF
TEST PROBE
components having such features are identified  by “
å
and  shaded  areas in the Replacement Parts Lists and
Schematic Diagrams.  For continued protection,
replacement parts must be identical to those used in the
original circuit.  The use of a substitute replacement parts
which do not have the same safety characteristics as the
factory recommended replacement parts shown in this
service manual, may create shock,  fire or other hazards.
CAUTION:  FOR CONTINUED PROTECTION
AGAINST A RISK OF FIRE REPLACE ONLY WITH
SAME TYPE F701 (6.3A, 250V)
» Use an AC voltmeter having with 5000 ohm per volt,
or higher, sensitivity or measure the AC voltage drop
across the resistor.
» Connect the resistor connection to all exposed metal
parts having a return to the chassis (antenna, metal
cabinet, screw heads, knobs and control shafts,
escutcheon, etc.) and measure the AC voltage drop
across the resistor.
All checks must be repeated with the AC cord plug
connection reversed. (If necessary, a nonpolarized
adaptor plug must be used only for the purpose of
completing these checks.)
Any reading of 0.75 V peak (this corresponds to 0.5
mA peak AC.) or more is excessive and indicates a
potential shock hazard which must be corrected before
returning the monitor to the owner.
BEFORE RETURNING THE PROJECTOR:
(Fire & Shock Hazard)
Before returning the receiver to the user, perform the
following safety checks:
1. Inspect all lead dress to make certain that leads are
not pinched, and check that hardware is not lodged
between the chassis and other metal parts in the
projector.
2. Inspect all protective devices such as non-metallic
control knobs, insulation materials, cabinet backs,
adjustment and compartment covers or shields,
isolation resistor-capacitor networks, mechanical
insulators, etc.
3. To be sure that no shock hazard exists, check for
leakage current in the following manner.
» Plug the AC cord directly into a 120 volt AC outlet. (For
North America)
» Plug the AC cord directly into a 110 ~ 240 volt AC outlet,
and connect the DC power cable into the projector's DC
jack. (Do not use an isolasion transformer for this test).
(For Others)
» Using two clip leads, connect a 1.5k ohm, 10 watt
resistor paralleled by a 0.15µF capacitor in series with
all exposed metal cabinet parts and a known earth
ground, such as electrical conduit or electrical ground
connected to an earth ground.
4
XV-Z3000
DT-500
PRECAUTIONS A PRENDRE LORS DE LA REPARATION
Ë
Ne peut effectuer la réparation qu' un technicien spécialisé qui s'est parfaitement
accoutumé à toute vérification de sécurité et  aux conseils suivants.
AVERTISSEMENT
1. N'entreprendre aucune modification de tout circuit.
C'est dangereux.
2. Débrancher le récepteur avant toute réparation.
AVANT DE RENDRE LE PROJECTEUR A
L'UTILISATEUR (Incendie et choc électrique)
Avant de rendre le projecteur à l'utilisateur, effectuer
les vérifications suivantes.
1. Inspecter tous les faisceaux de câbles pour s'assurer
que les fils ne soient pas pincés ou qu'un outil ne soit
pas placé entre le châssis et les autres pièces
métalliques du projecteur.
2. Inspecter tous les dispositifs de protection comme les
boutons de commande non-métalliques, les isolants, le
dos du coffret, les couvercles ou blindages de réglage
et de compartiment, les réseaux de résistance-capacité,
les isolateurs mécaniques, etc.
3. S'assurer qu'il n'y ait pas de danger d'électrocution en
vérifiant la fuite de courant, de la facon suivante:
• Enficher le cordon d'alimentation directement dans une
prise de 120V CA.
• Enficher le cordon d'alimentation directement dans une
prise de 110-240V CA, et brancher le câble d'alimentation
CC á la prise CC du projecteur. (Ne pas utiliser de
transformateur d'isolation pour cet essai.)
• A l'aide de deux fils à pinces, brancher une résistance
de 1.5 kΩ 10 watts en parallèle avec un condensateur
de 0.15µF en série avec toutes les pièces métalliques
exposées du coffret et une terre connue comme une
conduite électrique ou une prise de terre branchée à la
terre.
DVM
ECHELLE CA
1.5k ohm
10W
0.15 µF
SONDE D'ESSAI
AUX PIECES
METALLIQUES
EXPOSEES
BRANCHER A UNE
TERRE CONNUE
AVIS POUR LA SECURITE
De nombreuses pièces, électriques et mécaniques, dans
les projecteur à DMD™ présentent des caractéristiques
spéciales relatives à la sécurité,  qui ne sont souvent pas
évidentes à vue.
Le degré de protection ne peut pas être nécessairement
augmentée en utilisant des pièces de remplacement
étalonnées pour haute tension, puissance,  etc.
Les pièces de remplacement qui présentent ces
caractéristiques sont identifiées dans ce manuel;
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
les pièces électriques qui présentent ces particularités
sont identifiées par la marque “
å
” et hachurées dans la
liste des pièces de remplacement et les diagrammes
schématiques.  Pour assurer la protection, ces pièces
doivent être identiques à  celles  utilisées dans le circuit
d’origine.  L’utilisation de pièces qui n’ont pas les mêmes
caractéristiques que les pièces recommandées par l’usine,
indiquées dans ce manuel, peut provoquer des
électrocutions, incendies ou autres accidents.
PRECAUTION: POUR LA PROTECTION CONTINUE
C O N T R E   L E S   R I S Q U E S   D ' I N C E N D I E ,
REMPLACER LE FUSIBLE PAR UN FUSIBLE DE
MEME TYPE F701 (6.3A, 250V)
• Utiliser un voltmètre CA d'une sensibilité d'au moins
5000Ω/V pour mesurer la chute de tension CA en travers
de la résistance.
• Toucher avec la sonde d'essai les pièces métalliques
exposées qui présentent une voie de retour au châssis
(antenne, coffret métallique, tête des vis, arbres de
commande et des boutons, écusson, etc.) et mesurer la
chute de tension CA en-travers de la résistance. Toutes
les vérifications doivent être refaites après avoir inversé
la fiche du cordon d'alimentation. (Si nécessaire, une
prise d'adpatation non polarisée doit être utilisée dans le
but de terminer ces vérifications.)
La tension de pointe mesuée ne doit pas dépasser 0.75V
(correspondante au courant CA de pointe de
0.5mA).Dans le cas contraire, il y a une possibilité de
choc électrique qui doit être supprimée avant de rendre
le récepteur au client.
Page of 120
Display

Sharp XV-Z3000 Service Manual ▷ Download

  • DOWNLOAD Sharp XV-Z3000 Service Manual ↓ Size: 25.15 MB | Pages: 120 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp XV-Z3000 in PDF for free, which will help you to disassemble, recover, fix and repair Sharp XV-Z3000 Projector. Information contained in Sharp XV-Z3000 Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.