Sharp XG-V10WE (serv.man8) Service Manual ▷ View online

53
XG-V10WE
AN-SD1E/S422E
TROUBLE SHOOTING TABLE FOR PC I/F UNIT-7
Yes
Yes
Yes
Yes
No
No
No
No
Checking the COMPONENT input
Feed the COMPONENT signal 
to INPUT1 or INPUT 2.
Using panel key or remote 
controller, select INPUT1 or 
INPUT2.
Does image appear onscreen?
Are the colors as specified?
Is the signal type of 
COMPONENT?
Carry out the process 
adjustment.
Is the image contour as 
specified?
No problem with the 
COMPONENT input.
IC4 (CXA3516R) or IC25 
(CVIC_IC) defective.
Check the SOG circuit.
Set the signal type to 
COMPONENT.
»
Check the COMPONENT (1080I, 720P, 480P, etc.: 
480I not included) signals.
4
4
54
XG-V10WE
AN-SD1E/S422E
TROUBLE SHOOTING TABLE FOR PC I/F UNIT-8
Yes
Yes
No
No
Checking the SOG circuit
Measure the TL136 output on 
oscilloscope screen.
Is the composite sync signal 
reproduced in good timing?
Measure the C69 land on 
oscilloscope screen.
Does the Y signal contain 
sync signal?
SOG sync separation circuit 
defective.
No problem with the SOG 
circuit.
Check the input signal settings.
Input PWB defective.
55
XG-V10WE
AN-SD1E/S422E
TROUBLE SHOOTING TABLE FOR PC I/F UNIT-9
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Checking the VIDEO input
5
5
Feed the composite video 
signal to INPUT4 or INPUT 5.
Using panel key or remote 
controller, select INPUT4 or 
INPUT5.
Select the VIDEO signal type 
on user menu.
Does image appear onscreen?
Is the image free of distortion?
Are the colors as specified?
Measure the following outputs on 
oscilloscope screen: at pin (5)(R) 
of IC324, pin (3)(G) of IC326 and 
pin (5)(B) of IC326.
Is the video signal level 
between VRB and VRT?
Measure the output at pin (5) or 
(6) of IC323 on oscilloscope 
screen.
No problem with the VIDEO 
input.
Check the VIDEO sync signal.
IC310 or CVIC_IC defective.
Is the clamp pulse as 
specified?
Check the VIDEO sync signal.
CVIC_IC or its peripherals 
defective.
Clamp level setting IC (IC316, 
IC327 or IC323) or its 
peripherals defective.
Check the VIDEO sync signal.
Carry out the process 
adjustment.
» 
VRB: Bottom reference voltage at video ADC
» 
VRT: Top reference voltage at video ADC
» 
Checking the clamp pulse
56
XG-V10WE
AN-SD1E/S422E
TROUBLE SHOOTING TABLE FOR PC I/F UNIT-10
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Checking the VIDEO sync signal
Measure the TL135 output on 
oscilloscope screen.
Is the vertical sync signal as 
specified?
Measure the TL132 output on 
oscilloscope screen.
Is the horizontal sync signal as 
specified?
Are there horizontal and 
vertical sync signals at TL130 
and TL131?
Check the input signal settings.
Input PC board defective.
IC302 or its peripherals 
defective.
Is the pulse output at pin (4) of 
IC328 in the same timing as 
the horizontal signal?
CVIC_IC or its peripherals 
defective.
Is the pulse output at pin (5) of 
IC328 in the same timing as 
the pulse at pin (4)?
CVIC_IC or its peripherals 
defective.
Is there 69-MHz or so clock at 
FL102?
No problem with the VIDEO 
sync signal and clock.
IC328 (PLL_IC) or its 
peripherals defective.
» 
Checking the VIDEO vertical sync signal.
» 
Checking the VIDEO 
    vertical sync signal