17
XG-V10WE
AN-SD1E/S422E
4. Removing the PWBs
4-1. Remove the two lock screws from the DVI connector.
4-2. Remove the five lock screws from the PC I/F PWB. Lift this PWB off the output PWB unit.
4-3. Remove the four lock screws from the cooling fan. Remove the lock screw from the output sub-PWB unit and
disconnect the connectors. Lift the cooling fan and the output sub-PWB unit off the output PWB unit.
4-4. Disconnect the connectors from the output PWB unit.
4-5. Remove the four stud bolts and eight lock screws from the output PWB unit. Lift and detach the output PWB
unit.
4-6. Disconnect the connector (SP) of the signal PWB unit.
4-7. Remove the eight lock screws from the side terminal board.
4-8. Remove the lock screw from the terminal cover and detach the terminal cover.
4-9. Remove the three lock screws from the grounding plate behind the terminal cover and detach the grounding
plate.
4-10. Detach the terminal board from the left-side panel. Lift the input PWB unit and the signal PWB unit off position.
4-2
4-3
4-6
4-5
4-4
4-10
4-5
4-5
4-5
4-5
4-7
4-9
4-7
4-1
4-8
(TOP VIEW)
(F4)
(F8)
(S8)
(RL)
(D) (EA)
(F5)
(BP)
(TP)
(KY)
(RP)
(S7)
(F7) (F6)
(S4)
(S3)
(AZ)
FRONT
(S5)
(GP)
(AS)
(F1)
(RE)
(L)
(F3)
(F2)
(RD)
(LL)
(EC)
PC I/F PWB unit
Cooling fan
Output sub-PWB unit
Output PWB unit
Output 
sub-PWB 
unit
Output 
PWB unit
Input PWB unit
Left-side panel
`
Signal PWB unit
`
 Note: When reassembling, fit
the projection of the
terminal PWB shield in
the positioning hole of the
left-side panel.
18
XG-V10WE
AN-SD1E/S422E
5. Removing the power/ballast PWB unit assembly.
5-1. Remove the lock screw from the socket holder (with shorter lead) for the lamp unit 1. Slide sideway and
detach the holder.
5-2. Remove the lock screw from the socket holder (with longer lead) for the lamp unit 2. Slide sideway and
detach the holder.
5-3. Disconnect the connectors from the power/ballast PWB unit assembly.
5-4. Remove the six lock screws from the power/ballast PWB unit assembly. Lift and detach this assembly.
6. Removing the inlet PWB unit assembly.
6-1. Remove the three lock screws from the left-side panel at the inlet PWB unit assembly.
6-2. Disconnect the connectors from the inlet PWB unit assembly.
6-3. Remove the two lock screws from the bottom panel at the inlet PWB unit assembly. Lift and detach this
assembly.
7. Removing the optical mechanism unit.
7-1. Remove the five lock screws from the lamp fan assembly.
7-2. Remove the seven lock screws
from the optical mechanism unit.
Lift and detach this unit.
5-1
5-3
5-3
5-2
7-1
5-4
6-3
(PA)
(EC)
6-1
6-2
7-2
7-1
(BB)
(EA)
(PL)
(F7)
(F6)
7-1
Power/ballast PWB 
unit assembly
Lamp fan assembly
Optical mechanism unit
Left-side panel
Inlet PWB unit assembly
Bottom panel
19
XG-V10WE
AN-SD1E/S422E
Resetting the TOTAL LAMP TIMER
Resetting the counter
»
Draw out the lamp to be replaced. Turn on the power and the absence of the lamp is detected. Now reset the total
hour counter.
Resetting procedure
Condition
The internal
temperature is
abnormally high.
The lamp does
not light up.
The POWER
indicator flashes
in red when the
projector is on.
Problem
· Blocked air intake.
· Clogged air filter.
· Cooling fan breakdown.
· Internal circuit failure.
· Burnt-out lamp.
· Lamp circuit failure.
· The filter cover is open.
· The lens cover is miss-
ing.
Possible Solution
· Relocate the projector to an area with
proper ventilation.
· Clean the filter.
· Take the projector to your nearest Au-
thorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
· Carefully replace the lamp.
· Take the projector to your nearest Au-
thorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
· Securely install the filter cover.
· Remove the top lens cover
(CCOVA1785CE01) off the front panel.
Maintenance Indicator
TEMPERATURE
WARNING indicator
LAMP REPLACE-
MENT indicator
(LAMP1, LAMP2)
POWER indicator
Replacing one lamp
Replacing both lamps
1
Draw out the relevant lamp only.
Draw out both the lamps.
2
Turn on the main power.
3
Press POWER button to LCD projector on.
4
The LED indicator at the drawn-out lamp side starts flashing.
Press the ENTER key to reset the counter. The LED indicator goes out.
5
Turn off the main power. Fit a new lamp into position.
End
»
With just one of the lamps drawn out, the optical mechanism may get unstable in temperature. To avoid this,
the projector comes in the reset mode.
»
For two or more projectors, their counters cannot be reset at once using the remote controller. Press the
ENTER key for resetting.
»
In the process mode, the historical information is also reset.
20
XG-V10WE
AN-SD1E/S422E
THE OPTICAL UNIT OUTLINE
Layout of the optical system
Note: Layout for positioning the optical system.
M2 and M3 mirrors have a coat-
ing wedge (for different film thick-
ness).  Set up these mirrors, with
their markings positioned as
shown above, so that their
coated faces and both sides be
in the correct directions.
2 Output polarizer R
2 Output polarizer G
Projection Lens
R-LCD
Dichroic coating
(R transmission)
Dichroic coating
(G transmission)
M5
AL-coated mirror R
AL-deposited face
Marking
L2(R)
M2
G-LCD
Marking
L2(G)
M4
M6
B/G reflector
Dichroic coating
UV absorbing glass
PBS aperture
Fly-eye lens
UHP lamp
(Light source)
Marking
Prism array
UV-IR filter
UHP lamp
(Light source)
PBS
(polarization beam splitter)
Relay lens 1
(B transmission)
Dicroic coating
AL-deposited face
Relay lens 2
AL-coated mirror B
AL-coated mirror B
M3
L1
G01
G/R Reflector
Marking
B-DF
G02
G03
AL-deposited face
Relay lens 3
Input polarizer B
B-LCD
2 Output polarizer B
Cross dichroic prism
RED
GREEN
BLUE
2 See the assemble-illustration
for determing a direction of
the output polarizer.
Page of 59
Display

Click on the first or last page to see other XG-V10WE (serv.man8) service manuals if exist.