Sharp XG-MB70X (serv.man26) User Manual / Operation Manual ▷ View online
-21
Controlling the Projector Using RS-232C or Telnet
Save Settings and Quit
([S]Save & Quit)
Save set values and quit menu.
1
1
1
1
1 Enter “s” and press the “Enter” key.
2
2
2
2
2
2 Enter “y” and press the “Enter” key.
▼SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>s
All Connection will be disconnect.
Continue(y/n)? y
Apply New setting...Done.
All Connection will be disconnect.
Continue(y/n)? y
Apply New setting...Done.
1
2
Quit without Saving Set-
tings
tings
([Q]Quit Unchanged)
Quit menu without saving setting values.
1
1
1
1
1 Enter “q” and press the “Enter” key.
2
2
2
2
2
2 Enter “y” and press the “Enter” key.
▼SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>q
Quit Without Saving(y/n)? y
Setting Unchanged.
Quit Without Saving(y/n)? y
Setting Unchanged.
1
2
2
XG-MB70X_E_P20_30.p65
04.8.6, 2:25 PM
21
-22
Controlling the Projector Using RS-232C or Telnet
IP Address Setting
([1]IP Address)
Setting of IP address.
1
1
1
1
1 Enter “1” and press the “Enter” key.
2
2
2
2
2
2 Enter numerical value to be set and press the
“Enter” key.
Display IP address after change (*).
Display IP address after change (*).
Subnet Mask Setting
([2]Subnet Mask)
Setting subnet mask.
1
1
1
1
1 Enter “2” and press the “Enter” key.
2
2
2
2
2
2 Enter numerical value to be set and press the
“Enter” key.
Display subnet mask after change (*).
Display subnet mask after change (*).
The setting procedure for each item will be explained. For the basic procedure, please refer
to “Set Items” on page
to “Set Items” on page
20
.
setup>1
IP Address
IP Address
:192.168.150.2
Please Enter
:192.168.150.3
(change) —>
192.168.150.3
1
2
*
setup>2
Subnet Mask
Subnet Mask
:255.255.255.0
Please Enter
:255.0.0.0
(change) —>
255.0.0.0
1
2
*
Default Gateway Setting
([3]Default Gateway)
Setting default gateway.
1
1
1
1
1 Enter “3” and press the “Enter” key.
2
2
2
2
2
2 Enter numerical value to be set and press the
“Enter” key.
Display gateway address after change (*).
Display gateway address after change (*).
Note
• If the values for IP Address, Subnet Mask or Gate-
way of the projector have been changed via Telnet,
the computer for controlling cannot be connected
to the projector depending on the computer’s net-
work settings.
the computer for controlling cannot be connected
to the projector depending on the computer’s net-
work settings.
setup>3
note: “0.0.0.0” means “Using no default gateway.”
Gateway Address :0.0.0.0
Please Enter
note: “0.0.0.0” means “Using no default gateway.”
Gateway Address :0.0.0.0
Please Enter
:192.168.150.1
(change) —> 192.168.150.1
1
2
*
XG-MB70X_E_P20_30.p65
04.8.6, 4:53 PM
22
-23
Controlling the Projector Using RS-232C or Telnet
User Name Setting
([4]User Name)
Carrying out security protection using user name.
1
1
1
1
1 Enter “4” and press the “Enter” key.
2
2
2
2
2
2 Enter user name and press the “Enter” key.
Display set user name (*).
Note
• User name can be up to 8 characters.
• You can input the characters below :
• You can input the characters below :
a-z, A-Z, 0-9, -, _
• In the default state, user name is not set.
Password Setting
([5]Password)
Carrying out security protection using password.
1
1
1
1
1 Enter “5” and press the “Enter” key.
2
2
2
2
2
2 Enter password and press the “Enter” key.
Display set password (*).
Note
• Password can be up to 8 characters.
• You can input the characters below :
• You can input the characters below :
a-z, A-Z, 0-9, -, _
• In the default state, the password is not set.
setup>4
User Name
User Name
:
Please Enter
: XG-MB70X
(change) —> XG-MB70X
1
2
*
setup>5
Password
Password
:
Please Enter
: sharppj
(change) —> sharppj
1
2
*
RS-232C Baud Rate Set-
ting
ting
([6]RS-232C Baud Rate)
Setting of baud rate for RS-232C (COMPUTER and
PROJECTOR) terminals.
PROJECTOR) terminals.
1
1
1
1
1 Enter “6” and press the “Enter” key.
2
2
2
2
2
2 Select and enter the number 0 or 2 and press
the “Enter” key.
Display set baud rate (*).
Display set baud rate (*).
Note
• Set the projector’s baud rate to the same rate as
that used by the computer.
Projector Name Setting
([7]Projector Name)
It is possible to assign a projector name.
1
1
1
1
1 Enter “7” and press the “Enter” key.
2
2
2
2
2
2 Enter projector name.
Display set projector name (*).
Note
• Projector name can be up to 12 characters.
• You can input the characters below :
• You can input the characters below :
A-Z, 0-9, -, _, (,), space
(When “a-z” are input, they are converted to “A-Z”
automatically.)
(When “a-z” are input, they are converted to “A-Z”
automatically.)
• It is the same as the name which can be con-
firmed or set, using RS-232C commands “PJN0”,
“PJN1”, “PJN2” and “PJN3”.
“PJN1”, “PJN2” and “PJN3”.
setup>6
note: It sets both RS-232C (COMPUTER) and RS-232C (PROJECTOR).
0 ...
0 ...
9600 bps
2 ... 115200 bps
Baud Rate Select[0, 2] :2
RS-232C Baud Rate : 115200 bps
Baud Rate Select[0, 2] :2
RS-232C Baud Rate : 115200 bps
1
2
*
setup>7
Projector Name
Projector Name
: XG-MB70X
Please Enter
: MY XG-MB70X
(change) —>
MY XG-MB70X
1
2
*
XG-MB70X_E_P20_30.p65
04.8.6, 2:25 PM
23
-24
Controlling the Projector Using RS-232C or Telnet
Disconnecting All Connec-
tions
tions
([D]Disconnect All)
It is possible to disconnect all the TCP/IP connec-
tions currently recognized by the projector. Even if
the COM Redirect port is fixed in the Busy status
due to a problem, it is possible to force the Ready
status back by carrying out this disconnection.
tions currently recognized by the projector. Even if
the COM Redirect port is fixed in the Busy status
due to a problem, it is possible to force the Ready
status back by carrying out this disconnection.
1
1
1
1
1 Enter “d” and press the “Enter” key.
2
2
2
2
2
2 Enter “y” and press the “Enter” key.
Note
• If Disconnect All is performed, the connection to
the projector via network will be forcibly discon-
nected.
nected.
Entering ADVANCED
SETUP MENU
SETUP MENU
([A]Advanced Setup)
Enters ADVANCED SETUP MENU.
1
1
1
1
1 Enter “a” and press the “Enter” key.
Setting Auto Logout Time
(ADVANCED[1]Auto Logout Time)
If there is no input after a fixed time, the projector
automatically disconnects network connection using
the Auto Logout function. It is possible to set the time
until the projector is automatically disconnected in
units of a minute (from 1 to 65535 minutes).
automatically disconnects network connection using
the Auto Logout function. It is possible to set the time
until the projector is automatically disconnected in
units of a minute (from 1 to 65535 minutes).
1
1
1
1
1 Enter “1” and press the “Enter” key.
2
2
2
2
2
2 Enter numerical value and press the “Enter” key.
Display set numerical value (*).
Note
• If the set value is made 0, the Auto Logout func-
tion is disabled.
• If an invalid number is entered, an error message
(“Parameter Error!”) will be displayed and returns
the ADVANCED SETUP MENU.
the ADVANCED SETUP MENU.
Data Port Setting
(ADVANCED[2]Data Port)
Setting of TCP port number can be set in the range
of 1025 to 65535.
of 1025 to 65535.
1
1
1
1
1 Enter “2” and press the “Enter” key.
2
2
2
2
2
2 Enter numerical value and press the “Enter” key.
Display set numerical value (*).
Note
• Set according to need. Normally, use with the fac-
tory default setting.
setup>d
Disconnect All Connections(y/n)?y
Now Disconnecting...
Disconnect All Connections(y/n)?y
Now Disconnecting...
1
2
2
setup>a
******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time
******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time
[2]Data Port
[5]Network Ping Test
[6]Accept IP Addr(1)
[6]Accept IP Addr(1)
[7]Accept IP Addr(2)
[8]Accept IP Addr(3)
[9]Accept All IP Addr
[0]Search Port
[!]Restore Default Setting
[Q]Return to Main Menu
[Q]Return to Main Menu
advanced>
1
advanced>1
Valid range
Valid range
: 0 to 65535 (minute)
note: if you enter “0”, auto logout function will be disable.
Auto Logout Time : 5
Please Enter
Auto Logout Time : 5
Please Enter
:15
(change) —> 15
1
2
*
advanced>2
Valid range
Valid range
:1025 to 65535
Data Port
:10002
Please Enter
:10005
(change) —> 10005
1
2
*
XG-MB70X_E_P20_30.p65
04.8.6, 2:25 PM
24
Click on the first or last page to see other XG-MB70X (serv.man26) service manuals if exist.