Sharp XG-MB70X (serv.man26) User Manual / Operation Manual ▷ View online
-17
Setting the Projector Using RS-232C or Telnet
When Connecting Using
RS-232C
RS-232C
1
Launch general purpose terminal
emulator.
emulator.
2
Input settings for the RS-232C port
of the terminal emulator as follows.
of the terminal emulator as follows.
Baud Rate
: 9600 bps*
Data Length
: 8 bit
Parity Bit
: None
Stop Bit
: 1 bit
Flow Control : None
∗ This is the factory default setting. If the value
of Baud Rate for the projector has been
changed, set Baud Rate here according to
the changed value on the projector.
changed, set Baud Rate here according to
the changed value on the projector.
3
Input “PJS11234” and press the
“Enter” key.
“Enter” key.
4
“OK” is displayed. Input “PJS25678”
and press the “Enter” key within 10
seconds.
and press the “Enter” key within 10
seconds.
5
“User Name:” is displayed. Input the
user name and press the “Enter”
key.
user name and press the “Enter”
key.
• If a user name has not yet been set, just
press the “Enter” key.
6
“Password:” is displayed. Input the
password and press the “Enter” key.
password and press the “Enter” key.
• If a password has not yet been set, just press
the “Enter” key.
Connect the projector to a computer using RS-232C or Telnet, and open the SETUP MENU on
the computer to carry out various settings for the projector.
the computer to carry out various settings for the projector.
7
Input “setup” and press the “Enter”
key.
key.
• SETUP MENU will be displayed.
Note
• User name and password are not set in the fac-
tory default settings.
• If the user name or password is entered incor-
rectly three times, SETUP MENU will be quit.
▼SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>
XG-MB70X_E_P02_19.p65
04.8.6, 2:24 PM
17
-18
Setting the Projector Using RS-232C or Telnet
When Connecting Using
Telnet
Telnet
1
Click “Start” from the Windows
®
desk-
top and select “Run”.
2
Enter “telnet 192.168.150.2” in the text
box that opens up. (If the IP address
of the projector is 192.168.150.2.)
box that opens up. (If the IP address
of the projector is 192.168.150.2.)
3
Click the “OK” button.
4
“User Name:” is displayed. Input the
user name and press the “Enter”
key.
user name and press the “Enter”
key.
• If a user name has not yet been set, just
press the “Enter” key.
5
“Password:” is displayed. Input the
password and press the “Enter” key.
password and press the “Enter” key.
• If a password has not yet been set, just press
the “Enter” key.
6
Input “setup” and press the “Enter”
key.
key.
• SETUP MENU will be displayed.
Note
• If the IP address has been changed, ensure to
enter the new IP address in step 2.
• User name and password are not set in the fac-
tory default settings.
• If the user name or password is entered incor-
rectly three times in steps 4 or 5, SETUP MENU
will be quit.
will be quit.
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>
▼SETUP MENU
XG-MB70X_E_P02_19.p65
04.8.6, 2:24 PM
18
-19
Setting the Projector Using RS-232C or Telnet
SETUP MENU
(Main Menu)
[1]IP Address (Factory default setting : 192.168.150.2)
IP address settings. (Page
22
)
[2]Subnet Mask (Factory default setting :
255.255.255.0)
Subnet mask settings. (Page
Subnet mask settings. (Page
22
)
[3]Default Gateway (Factory default setting : Not
Used)
Default gateway settings. (Page
Default gateway settings. (Page
22
)
[4]User Name (Factory default setting : Not Re-
quired)
Setting of user name for security protection. (Page
Setting of user name for security protection. (Page
23
)
[5]Password (Factory default setting : Not Required)
Setting of password for security protection. (Page
23
)
[6] RS-232C Baud Rate (Factory default setting :
9600 bps)
Baud rate settings for the RS-232C terminals. (Page
Baud rate settings for the RS-232C terminals. (Page
23
)
[7] Projector Name (Factory default setting : XG-
MB70X)
It is possible to assign a projector name. (Page
It is possible to assign a projector name. (Page
23
)
[A]Advanced Setup
Enters ADVANCED SETUP MENU. (Page
24
)
[D]Disconnect All
Disconnect all connections. (Page
24
)
[V] View All Setting
Displays all setting values. (Page
20
)
Can also be used with ADVANCED SETUP MENU.
[S] Save & Quit
Save set values and quit menu. (Page
21
)
[Q]Quit Unchanged
Quit menu without saving setting values. (Page
21
)
ADVANCED SETUP MENU
[1]Auto Logout Time (Factory default setting : 5 min-
utes)
Setting of time until automatic disconnection of net-
work connection. (Page
Setting of time until automatic disconnection of net-
work connection. (Page
24
)
[2] Data Port (Factory default setting : 10002)
Setting the TCP port number used when exchang-
ing data. (Page
ing data. (Page
24
)
[5]Network Ping Test
It is possible to confirm that a network connection
between the projector and a computer etc. is work-
ing normally. (Page
between the projector and a computer etc. is work-
ing normally. (Page
25
)
[6] Accept IP Addr(1)
[7]Accept IP Addr(2)
[8]Accept IP Addr(3)
[9]Accept All IP Addr (Factory default setting : Ac-
[7]Accept IP Addr(2)
[8]Accept IP Addr(3)
[9]Accept All IP Addr (Factory default setting : Ac-
cept All)
For improved security, it is possible to set up to three
IP addresses allowing connection to the projector.
Set IP addresses can be cancelled using [9] Accept
All IP Addr. (Page
For improved security, it is possible to set up to three
IP addresses allowing connection to the projector.
Set IP addresses can be cancelled using [9] Accept
All IP Addr. (Page
25
)
[0] Search Port (Factory default setting : 5006)
Setting the port number used when searching for
the projector. (Page
the projector. (Page
26
)
[ ! ]Restore Default Setting
Restores all setting values that can be set using the
menu to the default state. (Page
menu to the default state. (Page
26
)
[Q]Return to Main Menu
Return to the main SETUP MENU. (Page
26
)
▼SETUP MENU
▼ADVANCED SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>
******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time
[1]Auto Logout Time
[2]Data Port
[5]Network Ping Test
[6]Accept IP Addr(1)
[6]Accept IP Addr(1)
[7]Accept IP Addr(2)
[8]Accept IP Addr(3)
[9]Accept All IP Addr
[0]Search Port
[!]Restore Default Setting
[Q]Return to Main Menu
[Q]Return to Main Menu
advanced>
XG-MB70X_E_P02_19.p65
04.8.6, 4:45 PM
19
-20
Controlling the Projector Using RS-232C or Telnet
View Setting Detail List
([V]View All Setting)
1
1
1
1
1 Enter “v” and press the “Enter” key.
Display all setting values(*).
Enter number or symbol of item to be selected on the SETUP MENU. When setting, input the
details to be set. Setting is carried out one item at a time, and saved at the end.
details to be set. Setting is carried out one item at a time, and saved at the end.
▼SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>v
Model Name
Model Name
: XG-MB70X
Projector Name
: XG-MB70X
MAC Address
: 08:00:1f:b1:b7:74
IP Address
: 192.168.150.2
Subnet Mask
: 255.255.255.0
Default Gateway
: Not Used
RS-232 Baud Rate : 9600 bps
Password
Password
: Not Required
**********(Advanced Status)**********
Data Port
Data Port
: 10002
Accept IP Address : Accept All
Auto Logout Time
Auto Logout Time
: 5 minutes
Search Port
: 5006
1
*
Set Items
Example: When setting IP Address (change from
192.168.150.2 to 192.168.150.3)
192.168.150.2 to 192.168.150.3)
1
1
1
1
1 Enter “1” (number of item to be set), and press
the “Enter” key.
Display current IP address (*1).
Display current IP address (*1).
2
2
2
2
2 Enter IP address to be set and press the “En-
ter” key.
Display IP address after change (*2).
Display IP address after change (*2).
3
3
3
3
3 Enter “v” and press the “Enter” key to verify
setting detail list.
IP address is being changed (*3).
IP address is being changed (*3).
Note
• Verification of setting detail list can be omitted.
• Setting details are not effective until they have
• Setting details are not effective until they have
been saved. (Page
21
)
• If an invalid number is entered, an error message
(“Parameter Error!”) will be displayed.
▼SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>1
IP Address
IP Address
: 192.168.150.2
Please Enter
: 192.168.150.3
(change)
—> 192.168.150.3
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>v
Model Name
Model Name
: XG-MB70X
Projector Name
: XG-MB70X
MAC Address
: 08:00:1f:b1:b7:74
IP Address
: 192.168.150.3
Subnet Mask
: 255.255.255.0
Default Gateway
: Not Used
RS-232C Baud Rate : 9600 bps
Password
Password
: Not Required
**********(Advanced Status)**********
Data Port
Data Port
: 10002
Accept IP Address
: Accept All
Busy Reply
: ERR+<CR> code
Input Hold Time
: 1000 milliseconds
Auto Logout Time
: 5 minutes
Search Port
: 5006
1
2
3
*1
*2
*3
XG-MB70X_E_P20_30.p65
04.8.6, 4:46 PM
20