-17
Setting the Projector Using RS-232C or Telnet
When Connecting Using
RS-232C
1
Launch general purpose terminal
emulator.
2
Input settings for the RS-232C port
of the terminal emulator as follows.
Baud Rate
: 9600 bps*
Data Length
: 8 bit
Parity Bit
: None
Stop Bit
: 1 bit
Flow Control : None
∗ This is the factory default setting. If the value
of Baud Rate for the projector has been
changed, set Baud Rate here according to
the changed value on the projector.
3
Input “PJS11234” and press the
“Enter” key.
4
“OK” is displayed. Input “PJS25678”
and press the “Enter” key within 10
seconds.
5
“User Name:” is displayed. Input the
user name and press the “Enter”
key.
• If a user name has not yet been set, just
press the “Enter” key.
6
“Password:” is displayed. Input the
password and press the “Enter” key.
• If a password has not yet been set, just press
the “Enter” key.
Connect the projector to a computer using RS-232C or Telnet, and open the SETUP MENU on
the computer to carry out various settings for the projector.
7
Input “setup” and press the “Enter”
key.
• SETUP MENU will be displayed.
Note
• User name and password are not set in the fac-
tory default settings.
• If the user name or password is entered incor-
rectly three times, SETUP MENU will be quit.
SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>
XG-MB70X_E_P02_19.p65
04.8.6, 2:24 PM
17
-18
Setting the Projector Using RS-232C or Telnet
When Connecting Using
Telnet
1
Click “Start” from the Windows
®
 desk-
top and select “Run”.
2
Enter “telnet 192.168.150.2” in the text
box that opens up. (If the IP address
of the projector is 192.168.150.2.)
3
Click the “OK” button.
4
“User Name:” is displayed. Input the
user name and press the “Enter”
key.
• If a user name has not yet been set, just
press the “Enter” key.
5
“Password:” is displayed. Input the
password and press the “Enter” key.
• If a password has not yet been set, just press
the “Enter” key.
6
Input “setup” and press the “Enter”
key.
• SETUP MENU will be displayed.
Note
• If the IP address has been changed, ensure to
enter the new IP address in step 2.
• User name and password are not set in the fac-
tory default settings.
• If the user name or password is entered incor-
rectly three times in steps 4 or 5, SETUP MENU
will be quit.
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>
SETUP MENU
XG-MB70X_E_P02_19.p65
04.8.6, 2:24 PM
18
-19
Setting the Projector Using RS-232C or Telnet
SETUP MENU 
(Main Menu)
[1]IP Address (Factory default setting : 192.168.150.2)
IP address settings. (Page 
22
)
[2]Subnet Mask (Factory default setting :
255.255.255.0)
Subnet mask settings. (Page 
22
)
[3]Default Gateway (Factory default setting : Not
Used)
Default gateway settings. (Page 
22
)
[4]User Name (Factory default setting : Not Re-
quired)
Setting of user name for security protection. (Page 
23
)
[5]Password (Factory default setting : Not Required)
Setting of password for security protection. (Page 
23
)
[6] RS-232C Baud Rate (Factory default setting :
9600 bps)
Baud rate settings for the RS-232C terminals. (Page
23
)
[7] Projector Name (Factory default setting : XG-
MB70X)
It is possible to assign a projector name. (Page 
23
)
[A]Advanced Setup
Enters ADVANCED SETUP MENU. (Page 
24
)
[D]Disconnect All
Disconnect all connections. (Page 
24
)
[V] View All Setting
Displays all setting values. (Page 
20
)
Can also be used with ADVANCED SETUP MENU.
[S] Save & Quit
Save set values and quit menu. (Page 
21
)
[Q]Quit Unchanged
Quit menu without saving setting values. (Page 
21
)
ADVANCED SETUP MENU
[1]Auto Logout Time (Factory default setting : 5 min-
utes)
Setting of time until automatic disconnection of net-
work connection. (Page 
24
)
[2] Data Port (Factory default setting : 10002)
Setting the TCP port number used when exchang-
ing data. (Page 
24
)
[5]Network Ping Test
It is possible to confirm that a network connection
between the projector and a computer etc. is work-
ing normally. (Page 
25
)
[6] Accept IP Addr(1)
[7]Accept IP Addr(2)
[8]Accept IP Addr(3)
[9]Accept All IP Addr (Factory default setting : Ac-
cept All)
For improved security, it is possible to set up to three
IP addresses allowing connection to the projector.
Set IP addresses can be cancelled using [9] Accept
All IP Addr. (Page 
25
)
[0] Search Port (Factory default setting : 5006)
Setting the port number used when searching for
the projector. (Page 
26
)
[ ! ]Restore Default Setting
Restores all setting values that can be set using the
menu to the default state. (Page 
26
)
[Q]Return to Main Menu
Return to the main SETUP MENU. (Page 
26
)
SETUP MENU
ADVANCED SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>
******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time
[2]Data Port
[5]Network Ping Test
[6]Accept IP Addr(1)
[7]Accept IP Addr(2)
[8]Accept IP Addr(3)
[9]Accept All IP Addr
[0]Search Port
[!]Restore Default Setting
[Q]Return to Main Menu
advanced>
XG-MB70X_E_P02_19.p65
04.8.6, 4:45 PM
19
-20
Controlling the Projector Using RS-232C or Telnet
View Setting Detail List
([V]View All Setting)
1
1
1
1
Enter “v” and press the “Enter” key.
Display all setting values(*).
Enter number or symbol of item to be selected on the SETUP MENU. When setting, input the
details to be set. Setting is carried out one item at a time, and saved at the end.
SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>v
Model Name
: XG-MB70X
Projector Name
: XG-MB70X
MAC Address
: 08:00:1f:b1:b7:74
IP Address
: 192.168.150.2
Subnet Mask
: 255.255.255.0
Default Gateway
: Not Used
RS-232 Baud Rate : 9600 bps
Password
: Not Required
**********(Advanced Status)**********
Data Port
: 10002
Accept IP Address : Accept All
Auto Logout Time
: 5 minutes
Search Port
: 5006
1
*
Set Items
Example: When setting IP Address (change from
192.168.150.2 to 192.168.150.3)
1
1
1
1
Enter “1” (number of item to be set), and press
the “Enter” key.
Display current IP address (*1).
2
2
2
2
Enter IP address to be set and press the “En-
ter” key.
Display IP address after change (*2).
3
3
3
3
Enter “v” and press the “Enter” key to verify
setting detail list.
IP address is being changed (*3).
Note
• Verification of setting detail list can be omitted.
• Setting details are not effective until they have
been saved. (Page 
21
)
• If an invalid number is entered, an error message
(“Parameter Error!”) will be displayed.
SETUP MENU
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>1
IP Address
: 192.168.150.2
Please Enter
: 192.168.150.3
(change)
—> 192.168.150.3
---------------------------------SETUP MENU--------------------------------
[1]IP Address
[2]Subnet Mask
[3]Default Gateway
[4]User Name
[5]Password
[6]RS-232C Baud Rate [7]Projector Name
[A]Advanced Setup
[D]Disconnect All
[V]View All Setting
[S]Save & Quit
[Q]Quit Unchanged
setup>v
Model Name
: XG-MB70X
Projector Name
: XG-MB70X
MAC Address
: 08:00:1f:b1:b7:74
IP Address
: 192.168.150.3
Subnet Mask
: 255.255.255.0
Default Gateway
: Not Used
RS-232C Baud Rate : 9600 bps
Password
: Not Required
**********(Advanced Status)**********
Data Port
: 10002
Accept IP Address
: Accept All
Busy Reply
: ERR+<CR> code
Input Hold Time
: 1000 milliseconds
Auto Logout Time
: 5 minutes
Search Port
: 5006
1
2
3
*1
*2
*3
XG-MB70X_E_P20_30.p65
04.8.6, 4:46 PM
20
Page of 30
Display

Click on the first or last page to see other XG-MB70X (serv.man26) service manuals if exist.