DOWNLOAD Sharp MX-M266N / MX-M316N / MX-M356N (serv.man5) Service Manual ↓ Size: 26.04 MB | Pages: 74 in PDF or view online for FREE

Model
MX-M266N MX-M316N MX-M356N (serv.man5)
Pages
74
Size
26.04 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Installation Manual (Revised December 2016).
File
mx-m266n-mx-m316n-mx-m356n-sm5.pdf
Date

Sharp MX-M266N / MX-M316N / MX-M356N (serv.man5) Service Manual ▷ View online

MX-265N  MX-EB13 (USB WIRELESS LAN ADAPTER)  22 – 1
1
1
MX-265N
Service Manual
 
[22] MX-EB13 (USB WIRELESS LAN ADAPTER)
1.  Unpacking
A. Check the packed items
2.  Installation
NOTE: Before installation, be sure to turn both the operation and
main power switches off and disconnect the power plug
from the power outlet. And, disconnect the LAN cable and
do not connect the USB adapter after installing the wireless
LAN. Perform the appropriate action for the customer not to
connect the LAN cable. 
1)
Connect the USB adapter. 
NOTE : Be sure to connect the USB adapter to the connector
at the rear side of the machine.  Do not connect the USB
adapter to the connector at the Panel unit.  
2)
Restart the machine.
NOTE : When the LAN cable is changed to wire type to the
wireless type or the cable is changed from the wireless type to
the wire type, be sure to restart the machine. 
3.  Change system setting
1)
Enter the SIM26-50 and change [E. WIRELESS SET] from 0 to
1 to activate the wireless LAN setting. 
2)
Change the connection type to "Wireless (Infrastructure
Mode)" or "Wired + Wireless (Ad-hoc Mode)" in the [SYSTEM
SETTINGS] menu depending on the customer’s environment. 
No.
Name
Quantity
1
USB adaptor for wireless LAN
1
2
Users manual
1
3
Warning sticker
1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)81&7,216(77,1*
˷̚˹
˖%:5(9(56(<(6
˖),1,6+(5)81&7,21<(6
˖)(('75$<&2/25<(6
˖/21*6,=(35,1712
˖:,5(/(666(712
2.
1
: ‘15/May
MX-M316N  Dehumidifying heater kit  23 – 1
MX-M316N
Service Manual
 
[23] Dehumidifying heater kit
1.  Parts list
Kit name
Kit code
No.
Part name
Part code
Q'ty
Remarks
Heater electric 
component kit
DKIT-0021QSZZ
1
Dehumidifier heater control switch 
QSW-C9294QCZZ 
1
2
Dehumidifier heater control switch label
TLABZ5256FCZZ 
1
3
Supporter LSUPP0140FCPZ
4
4
WH PWB 
CPWBF1935FCE1
1
5
WH PWB harness
DHAI-0898QSPZ
1
6
WH SW harness
DHAI-0899QSPZ
1
7
PCU-WH harness
DHAI-0908QSPZ
1
8
SCN-WH harness
DHAI-0901QSPZ
1
9
Saddle
LHLDW2328FCPZ 
1
10
Screw
XBPS730P08KS0
1
$( 0/7%2
Kit name
Kit code
No.
Part name
Part code
Q'ty
Remarks
Scanner heater kit
DKIT-0427FC11 
(120V series)
DKIT-0427FC12 
(230V series)
1
Scanner heater (120V)
RHETP0129FCPZ
1
Scanner heater (230V)
RHETP0130FCPZ
2
Heater fixing plate 
LPLTM6923FCZZ 
1
3
Banding band 
LBNDJ0013FCZ1 
2
4
Clamp LHLDW7011XCZZ 
5
5
Screw (M3 x 4 Round-tipped) 
LX-BZ1041FCZZ 
2
6
Screw (M4 x 6 Bind machine screw) 
XBBS740P06000 
1
7
Snap band 
LBNDJ0043FCZZ 
1
8
SCN-WH harness
DHAI-4702FCPZ
1
Not used.
9
Edge holder
LBSHC0353FCZZ
1
Not used.
5
6
7
9
2
3
4
8
1
MX-M316N  Dehumidifying heater kit  23 – 2
2.  Installation
NOTE: Before installation, be sure to turn both the operation and
main power switches off and disconnect the power plug
from the power outlet. Make double sure that the data lamp
on the operation panel does not light up or blink when per-
forming installation. 
A. Heater electric component kit installation
(1)
External fixture removal
1)
Remove the rear cabinet.
2)
Remove the left cabinet.
(2)
WH PWB attachment
1)
Disconnect all harnesses to the PCU PWB and remove the
PCU PWB.
2) Attach the supporter, and attach the WH PWB.
3)
Connect the harnesses bundled with an omega clamp to the
WH PWB according to the connector shapes and colors.
NOTE:Connectors CN3 and CN4 can be used commonly.
4)
Connect all harnesses to the PCU PWB and fix the PCU PWB.
MX-M316N  Dehumidifying heater kit  23 – 3
(3)
Dehumidifier heater control switch attachment
1)
Connect the WH harness to the dehumidifier heater control
switch, and attach the dehumidifier heater control switch.
(4)
Harness connection
1)
Connect the WH PWB harness with connecting the WH PWB
harness and the AC power harness by the clamp. 
NOTE : The dummy connector is originally fixed. 
2)
Connect the WH SW harness to the PWB and the heater con-
trol switch. 
3)
Connect the WH harness from the machine to the WH PWB. 
4)
Connect the PCU-WH harness to the WH PWB.
5)
Connect the SCN-WH harness to the WH PWB.
Page of 74
Display

Click on the first or last page to see other MX-M266N / MX-M316N / MX-M356N (serv.man5) service manuals if exist.