Copying Equipment / MX7580N - Handy Guide Version 1 May 2017 - NOTE - Handy Guides are NOT a substitute for Service Manuals and Parts Guides
File
mx-6580n-mx-7580n-sm2.pdf
Date

Sharp MX-6580N / MX-7580N (serv.man2) Handy Guide ▷ View online

SHARP
 
FIRMWARE UPDATE
 
 
41
 
4.  Click Browse to navigate to the location of the updated firmware file and select Open:- 
 
 
 
5.  Press Execute to start the firmware update. 
 
Note: Once the machine has entered “service download mode”, the update will commence and the  
 
           progress will be displayed. 
 
 
 
6.  When the firmware upgrade is complete, click Reboot to execute a remote restart of the machine. 
 
 
 
Firmware Upgrade is complete
FIRMWARE RECOVERY 
SHARP  
 
42
 
In the event of a power failure during a firmware update, the device may fail to “reboot” because of 
corrupted firmware. Using the CN Update procedure described below, this function is used to 
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and 
various options by means of a USB memory. 
 
MENU KEY REFERENCE: 
 
The following five keys are used to perform firmware recovery mode. For MX-6580N/7580N series, touch  
the LCD panel within the area shown below to select the desired key:- 
 
 
 
CN UPDATE - Firmware Recovery Procedure:- 
 
1.  Power off the MFP and remove the MFP Rear Cabinet & Screws. 
 
2.  Set the MFP CONTROL PWB CN UPDATE DIP-SW to ON:- 
 
 
 
Note: If a Boot failure has occurred, replace the Boot FlashROM. 
 
3.  Install the USB Memory containing the MX-6580N/7580N firmware into the USB slot. 
Note: The Firmware file (*.sfu) must only be saved on the main or one level lower directory of the 
           USB Memory. 
 
4.  Power ON the MFP device - the UPDATE PROGRAM INIT PLEASE WAIT boot menu should appear  
after approx 10 seconds, followed by VERSION CHECK CONFIG: information:-. 
 
 
 
 
 
Version Check 
  Conf: 00050000 
Update Program Init 
Please wait
 
SHARP
 
FIRMWARE RECOVERY
 
 
43
 
5.  Select FIRM UPDATE Mode by using the [Menu] & [Back] keys. Using the [UP] and [DOWN] keys, 
navigate and select the required firmware SFU. 
 
 
 
 
Note: 
Use the [OK] key when a directory name is selected to browse through to the sub folder(s) or  
the [BACK] key to return to the parent folder(s). 
 
6.  Press [OK] to commence Firmware Update. – It may take approx. 1-2 minutes to read the SFU file. 
After reading is completed, the firmware update (writing) will commence automatically. 
 
 
 
 
 
Note:   
The abbreviated name/location of the firmware that is being updated will appear in the upper  
right corner. 
 
7.  If the firmware upgrade completes successfully, RESULT OK will be displayed:- 
 
 
 
 
Result: NG = Update failed;    Result: Not Update = Update is not executed. 
 
8.  Power off the MFP and return the MFP CONTROL PWB CN UPDATE DIP-SW to OFF (Default):- 
 
 
 
9.  Power ON the MFP, and confirm that the machine boots up normally. 
 
10. Power OFF the MFP and refit the MFP PWB Rear Cabinet & Screws. 
 
11. Check/confirm the firmware version using SIM 22-05. 
 
CN UPDATE - Firmware Recovery Procedure is now complete. 
 
Firm Update 
> 0100S200.sfu
 
Firm Update 
    Reading Data
 
Firm Update              IcuM 
    Writing Data
 
Firm Update           IcuM 
    Result  :  OK
 
Firm Update 
    From USB Memory
 
E-MANUAL UPDATE 
SHARP  
 
44
 
1.  Using a PC, copy the E-Manual Update file onto 
the root of a USB memory device (as shown). 
 
Note: The E-Manual firmware consists of 1 file 
(*.UAR). 
 
 
 
2.  Insert the USB memory device containing the 
E-Manual firmware file into the main USB Port 
and enter Simulation 49-03 [E-MANUAL 
UPDATE].
 
Note: 
When using Easy Mode, select Version 
Upgrade
 from the Installation tab and execute 
SIM49-03 E-Manual Update. In addition, if no 
USB device is detected, an error message will 
be displayed. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.  Browse and select the E-manual update file 
– example shown = Manual_0100S200.uar 
 
 
 
 
 
 
 
 
 
 
 
 
4.  The current and updated version should then 
be displayed. Press Execute to commence the 
E-manual upgrade. 
 
 
 
Update File Checking and a progress of the 
firmware update will be displayed:- 
 
 
 
5.  Once the update is complete, press OK to exit 
simulation mode:- 
 
 
 
E-Manual update is complete. 