MX-7000N  SIMULATION  7 – 46
 
43-21
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-1) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
X
HL UM HEAVY2 
BW LL
Correction value for LL environment 
black and white heavy paper 2 upper 
thermistor main set value
65
Y
HL LM HEAVY2 
BW LL
Correction value for LL environment 
black and white heavy paper 2 lower 
thermistor main set value
65
Z
HL US HEAVY2 
BW LL
Correction value for LL environment 
black and white heavy paper 2 upper 
thermistor sub set value
65
AA
HL EX HEAVY2 
BW LL
Correction value for LL environment 
black and white heavy paper 2 
external thermistor set value
50
AB
HL UM HEAVY2 
CL LL
Correction value for LL environment 
heavy paper 2 upper thermistor main 
set value
65
AC
HL LM HEAVY2 
CL LL
Correction value for LL environment 
color heavy paper 2 lower thermistor 
main set value
65
AD
HL US HEAVY2 
CL LL
Correction value for LL environment 
heavy paper 2 upper thermistor sub 
set value
65
AE
HL EX HEAVY2 
CL LL
Correction value for LL environment 
color heavy paper 2 external 
thermistor set value
60
AF
HL_UM OHP LL
Correction value for OHP upper 
thermistor main set value under LL 
environment
65
AG
HL_LM OHP LL
Correction value for LL environment 
OHP lower thermistor mains et value
65
AH
HL_US OHP LL
Correction value for OHP upper 
thermistor sub set value under LL 
environment
65
AI
HL_EX OHP LL
Correction value for OHP external 
thermistor set value under LL 
environment
50
AJ
HL_UM 
ENVELOPE LL
Correction value for envelope upper 
thermistor main set value under LL 
environment
60
AK
HL_LM 
ENVELOPE LL
Correction value for LL environment 
envelope lower thermistor main set 
value
60
AL
HL_US 
ENVELOPE LL
Correction value for envelope upper 
thermistor sub set value under LL 
environment
60
AM
HL_EX 
ENVELOPE LL
Correction value for envelope 
external thermistor set value under 
LL environment
50
AN
HL_UM E-STAR 
LL
Correction value for upper thermistor 
main set value when preheating 
under LL environment
60
AO
HL_US E-STAR 
LL
Correction value for LL environment 
preheating upper thermistor sub set 
value
60
AP
HL_EX E-STAR 
LL
Correction value for LL environment 
preheating external thermistor set 
value
55
AQ
HL_UM PRE-
JOB LL 
Correction value for upper thermistor 
main set value when recovering from 
preheating under LL environment
60
AR
HL UM THIN 
PAPER BW LL
Correction value for LL environment 
black and white thin paper upper 
thermistor main set value
55
AS
HL LM THIN 
PAPER BW LL
Correction value for LL environment 
black and white thin paper lower 
thermistor main set value
55
AT
HL US THIN 
PAPER BW LL
Correction value for LL environment 
black and white thin paper upper 
thermistor sub set value
55
AU
HL EX THIN 
PAPER BW LL
Correction value for LL environment 
black and white thin paper external 
thermistor set value
50
AV
HL UM THIN 
PAPER CL LL
Correction value for LL environment 
color thin paper upper thermistor 
main set value
55
Item
Default 
value
A
W
HL LM THIN 
PAPER CL LL
Correction value for LL environment 
color thin paper lower thermistor 
main set value 
55
AX
HL US THIN 
PAPER CL LL
Correction value for LL environment 
color thin paper upper thermistor sub 
set value
55
AY
HL EX THIN 
PAPER CL LL
Correction value for LL environment 
color thin paper external thermistor 
set value 
50
AZ
HL UM THIN 
PAPER READY 
LL
Correction value for LL environment 
thin paper ready upper thermistor 
main temperature value
55
BA
HL UM REC 
PAPER BW LL
Correction value for LL environment 
black and white recycled paper upper 
thermistor main set value
55
BB
HL LM REC 
PAPER BW LL
Correction value for LL environment 
black and white recycled paper lower 
thermistor main set value
55
BC
HL US REC 
PAPER BW LL
Correction value for LL environment 
black and white recycled paper upper 
thermistor sub set value
55
BD
HL EX REC 
PAPER BW LL
Correction value for LL environment 
black and white recycled paper 
external thermistor set value
50
BE
HL UM REC 
PAPER CL LL
Correction value for LL environment 
color recycled paper upper 
thermistor main set value
55
BF
HL LM REC 
PAPER CL LL
Correction value for LL environment 
color recycled paper lower thermistor 
main set value
55
BG
HL US REC 
PAPER CL LL
Correction value for LL environment 
color recycled paper upper 
thermistor sub set value
55
BH
HL EX REC 
PAPER CL LL
Correction value for LL environment 
color recycled paper external 
thermistor set value
50
BI
HL UM REC 
PAPER READY 
LL
Correction value for LL environment 
recycled paper ready upper 
thermistor main temperature value
55
Item
Default 
value
A : 65
HL_UM READY LL
B : 65
HL_LM READY LL
C : 65
HL_US READY LL
D : 60
HL_EX READY LL
A:
SIMULATION NO.43-20
FUSER TEMP ADJUSTMENT (LL)
65
1
99
OK
TEST
CLOSE
E : 65
HL_UM PLAIN BW LL
F : 65
HL_LM PLAIN BW LL
G : 65
HL_US PLAIN BW LL
H : 50
HL_EX PLAIN BW LL
I : 60
HL_UM PLAIN CL LL
J : 60
HL_LM PLAIN CL LL
K : 60
HL_US PLAIN CL LL
L : 50
HL_EX PLAIN CL LL
MX-7000N  SIMULATION  7 – 47
3)
Press [OK] key.
The set value in step 2 is saved. 
Correction value: -49 to +49, 1 count = 1
°C change
Item
Default 
value
A
HL_UM READY 
HH
Correction value for upper thermistor 
main set value when ready standby 
under HH environment
50
B
HL_LM READY 
HH
Correction value for HH environment 
ready standby lower thermistor main 
set value
50
C
HL_US READY 
HH
Correction value for upper thermistor 
sub set value when ready standby 
under HH environment
50
D
HL_EX READY 
HH
Correction value for external 
thermistor set value when ready 
under HH environment
50
E
HL_UM PLAIN 
BW HH
Correction value for black and white 
plain paper upper thermistor main set 
value under HH environment
50
F
HL_LM PLAIN 
BW HH
Correction value for HH environment 
black and white plain paper lower 
thermistor main set value 
50
G
HL_US PLAIN 
BW HH
Correction value for black and white 
plain paper upper thermistor sub set 
value under HH environment
50
H
HL_EX PLAIN 
BW HH
Correction value for black and white 
plain paper external thermistor set 
value under HH environment
50
I
HL_UM PLAIN 
CL HH
Correction value for color plain paper 
upper thermistor main set value 
under HH environment
50
J
HL_LM PLAIN 
CL HH
Correction value for HH environment 
color plain paper lower thermistor 
main set value
50
K
HL_US PLAIN 
CL HH
Correction value for color plain paper 
upper thermistor sub set value under 
HH environment
50
L
HL_EX PLAIN CL 
HH
Correction value for color plain paper 
external thermistor set value under 
HH environment
50
M
WARMUP 
FUMON HL_UM 
T HH
Correction value for fusing motor 
previous rotation start external 
thermistor set value under HH 
environment
50
N
WARMUP 
FUMOFF HL_EX 
TEMP HH
Correction value for HH environment 
fusing motor front rotation 
continuation time
50
O
WARMUP END 
TIME HH
Correction value for warm-up 
completion time under HH 
environment
50
P
HL_UM HEAVY1 
BW HH
Correction value for HH environment 
black and white heavy paper 1 upper 
thermistor main set value
50
Q
HL_LM HEAVY1 
BW HH
Correction value for HH environment 
black and white heavy paper 1 lower 
thermistor main set value
50
R
HL_US HEAVY1 
BW HH
Correction value for HH environment 
black and white heavy paper 1 upper 
thermistor sub set value
50
S
HL_EX HEAVY1 
BW HH
Correction value for HH environment 
black and white heavy paper 1 
external thermistor set value
50
T
HL UM HEAVY1 
CL HH
Correction value for HH environment 
heavy paper 1 upper thermistor main 
set value
50
U
HL LM HEAVY1 
CL HH
Correction value for HH environment 
color heavy paper 1 lower thermistor 
main set value
50
V
HL US HEAVY1 
CL HH
Correction value for HH environment 
heavy paper 1 upper thermistor sub 
set value
50
W
HL EX HEAVY1 
CL HH
Correction value for HH environment 
color heavy paper 1 external 
thermistor set value
50
X
HL UM HEAVY2 
BW HH
Correction value for HH environment 
black and white heavy paper 2 upper 
thermistor main set value
50
Y
HL LM HEAVY2 
BW HH
Correction value for HH environment 
black and white heavy paper 2 lower 
thermistor main set value
50
Z
HL US HEAVY2 
BW HH
Correction value for HH environment 
black and white heavy paper 2 upper 
thermistor sub set value
50
AA
HL EX HEAVY2 
BW HH
Correction value for HH environment 
black and white heavy paper 2 
external thermistor set value
50
AB
HL UM HEAVY2 
CL HH
Correction value for HH environment 
heavy paper 2 upper thermistor main 
set value
50
AC
HL LM HEAVY2 
CL HH
Correction value for HH environment 
color heavy paper 2 lower thermistor 
main set value
50
AD
HL US HEAVY2 
CL HH
Correction value for HH environment 
heavy paper 2 upper thermistor sub 
set value
50
AE
HL EX HEAVY2 
CL HH
Correction value for HH environment 
color heavy paper 2 external 
thermistor set value
50
AF
HL_UM OHP HH
Correction value for OHP upper 
thermistor main set value under HH 
environment
50
AG
HL_LM OHP HH
Correction value for HH environment 
OHP lower thermistor mains et value
50
AH
HL_US OHP HH
Correction value for OHP upper 
thermistor sub set value under HH 
environment
50
AI
HL_EX OHP HH
Correction value for OHP external 
thermistor set value under HH 
environment
50
AJ
HL_UM 
ENVELOPE HH
Correction value for enveloper upper 
thermistor main set value under HH 
environment
50
AK
HL_LM 
ENVELOPE HH
Correction value for HH environment 
envelope lower thermistor main set 
value
50
AL
HL_US 
ENVELOPE HH
Correction value for enveloper upper 
thermistor sub set value under HH 
environment
50
AM
HL_EX 
ENVELOPE HH
Correction value for envelope 
external thermistor set value under 
HH environment
50
AN
HL_UM E-STAR 
HH
Correction value for upper thermistor 
main set value when preheating 
under HH environment
50
AO
HL US E-STAR 
HH
Correction value for HH environment 
preheating upper thermistor sub set 
value
50
AP
HL EX E-STAR 
HH
Correction value for HH environment 
preheating external thermistor set 
value
50
AQ
HL_UM PRE-
JOB HH 
Correction value for upper thermistor 
main set value when recovering from 
preheating under HH environment
50
AR
HL UM THIN 
PAPER BW HH
Correction value for HH environment 
black and white thin paper upper 
thermistor main set value
45
AS
HL LM THIN 
PAPER BW HH
Correction value for HH environment 
black and white thin paper lower 
thermistor main set value
45
AT
HL US THIN 
PAPER BW HH
Correction value for HH environment 
black and white thin paper upper 
thermistor sub set value
45
AU
HL EX THIN 
PAPER BW HH
Correction value for HH environment 
black and white thin paper external 
thermistor set value
45
AV
HL UM THIN 
PAPER CL HH
Correction value for HH environment 
color thin paper upper thermistor 
main set value
45
Item
Default 
value
MX-7000N  SIMULATION  7 – 48
 
43-22
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environment correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved. 
Correction value: -49 to +49, 1 count = 1
°C change
A
W
HL LM THIN 
PAPER CL HH
Correction value for HH environment 
color thin paper lower thermistor 
main set value 
45
AX
HL US THIN 
PAPER CL HH
Correction value for HH environment 
color thin paper upper thermistor sub 
set value
45
AY
HL EX THIN 
PAPER CL HH
Correction value for HH environment 
color thin paper external thermistor 
set value 
45
AZ
HL UM THIN 
PAPER READY 
HH
Correction value for HH environment 
thin paper ready upper thermistor 
main temperature value
45
BA
HL UM REC 
PAPER BW HH
Correction value for HH environment 
black and white recycled paper upper 
thermistor main set value
45
BB
HL LM REC 
PAPER BW HH
Correction value for HH environment 
black and white recycled paper lower 
thermistor main set value
45
BC
HL US REC 
PAPER BW HH
Correction value for HH environment 
black and white recycled paper upper 
thermistor sub set value
45
BD
HL EX REC 
PAPER BW HH
Correction value for HH environment 
black and white recycled paper 
external thermistor set value
45
BE
HL UM REC 
PAPER CL HH
Correction value for HH environment 
color recycled paper upper 
thermistor main set value
45
BF
HL LM REC 
PAPER CL HH
Correction value for HH environment 
color recycled paper lower thermistor 
main set value
45
BG
HL US REC 
PAPER CL HH
Correction value for HH environment 
color recycled paper upper 
thermistor sub set value
45
BH
HL EX REC 
PAPER CL HH
Correction value for HH environment 
color recycled paper external 
thermistor set value
45
BI
HL UM REC 
PAPER READY 
HH
Correction value for HH environment 
recycled paper ready upper 
thermistor main temperature value
45
Item
Default 
value
A : 50
;
HL_UM READY HH
B : 50
;
HL_LM READY HH
C : 50
;
HL_US READY HH
D : 50
;
HL_EX READY HH
A:
SIMULATION NO.43-21
FUSER TEMP ADJUSTMENT (HH)
50
1
99
OK
TEST
CLOSE
E : 50
;
HL_UM PLAIN BW HH
F : 50
;
HL_LM PLAIN BW HH
G : 50
;
HL_US PLAIN BW HH
H : 50
;
HL_EX PLAIN BW HH
I : 50
;
HL_UM PLAIN CL HH
J : 50
;
HL_LM PLAIN CL HH
K: 50
;
HL_US PLAIN CL HH
L: 50
;
HL_EX PLAIN CL HH
Item
Default 
value
A
HL_UM PLAIN 
BW DUP LL
Correction value for black and white 
plain paper duplex upper thermistor 
main set value under LL environment
60
B
HL_LM PLAIN 
BW DUP LL
Correction value for LL environment 
black and white plain paper duplex 
lower thermistor main set value
60
C
HL_US PLAIN 
BW DUP LL
Correction value for black and white 
plain paper duplex upper thermistor 
sub set value under LL environment
60
D
HL_EX PLAIN 
BW DUP LL
Correction value for black and white 
plain paper duplex external thermistor 
set value under LL environment
50
E
PLAIN BW DUP 
APP CNT LL
Correction value for black and white 
plain paper duplex applicable number 
of sheets under LL environment
50
F
HL_UM PLAIN 
CL DUP LL
Correction value for color plain paper 
duplex upper thermistor main set value 
under LL environment
55
G
HL_LM PLAIN 
CL DUP LL
Correction value for LL environment 
color plain paper duplex lower 
thermistor main set value
55
H
HL_US PLAIN 
CL DUP LL
Correction value for color plain paper 
duplex upper thermistor sub set value 
under LL environment
55
I
HL_EX PLAIN 
CL DUP LL
Correction value for color plain paper 
duplex external thermistor set value 
under LL environment
50
J
PLAIN CL DUP 
APP CNT LL
Correction value for color plain paper 
duplex applicable number of sheets 
under LL environment
50
K
HL_UM HEAVY 
BW DUP LL
Correction value for black and white 
heavy paper duplex upper thermistor 
main set value under LL environment
60
L
HL_LM HEAVY 
BW DUP LL
Correction value for LL environment 
black and white duplex lower thermistor 
main set value
60
M
HL_US HEAVY 
BW DUP LL
Correction value for black and white 
heavy paper duplex upper thermistor 
sub set value under LL environment
60
N
HL_EX HEAVY 
BW DUP LL
Correction value for black and white 
heavy paper duplex external thermistor 
set value under LL environment
50
O
HEAVY BW 
DUP APP CNT 
LL
Correction value for black and white 
heavy paper duplex applicable number 
of sheets under LL environment
50
P
HL_UM HEAVY 
CL DUP LL
Correction value for color heavy paper 
duplex upper thermistor main set value 
under LL environment
65
Q
HL_LM HEAVY 
CL DUP LL
Correction value for LL environment 
black and white heavy paper duplex 
lower thermistor main set value
65
R
HL_US HEAVY 
CL DUP LL
Correction value for color heavy paper 
duplex upper thermistor sub set value 
under LL environment
65
S
HL_EX HEAVY 
CL DUP LL 
Correction value for color heavy paper 
duplex external thermistor set value 
under LL environment
65
T
HEAVY CL DUP 
APP CNT LL
Correction value for color heavy paper 
duplex applicable number of sheets 
under LL environment
50
MX-7000N  SIMULATION  7 – 49
 
43-23
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-4) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved. 
Correction value: -49 to +49, 1 count = 1
°C change
 
43-24
Purpose
Adjustment/Setting
Function (Purpose) Used to set the correction of the tempera-
ture adjustment value of SIM 43-1 and 43-
4. 
Section
Operation/Procedure
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved. 
Correction value: -49 to +49, 1 count = 1
°C change
Item
Default 
value
A
HL_UM PLAIN 
BW DUP HH
Correction value for black and white 
upper thermistor main set value under 
HH environment
50
B
HL_LM PLAIN 
BW DUP HH
Correction value for HH environment 
black and white plain paper duplex 
lower thermistor main set value
50
C
HL_US PLAIN 
BW DUP HH
Correction value for black and white 
upper thermistor sub set value under 
HH environment
50
D
HL_EX PLAIN 
BW DUP HH
Correction value for black and white 
plain paper duplex external thermistor 
set value under HH environment
50
E
PLAIN BW DUP 
APP CNT HH
Correction value for black and white 
plain paper duplex applicable number 
of sheets under HH environment
50
F
HL_UM PLAIN 
CL DUP HH
Correction value for color plain paper 
duplex upper thermistor main set 
value under HH environment
50
G
HL_LM PLAIN CL 
DUP HH
Correction value for HH environment 
color plain paper duplex lower 
thermistor main set value
50
H
HL_US PLAIN CL 
DUP HH
Correction value for color plain paper 
duplex upper thermistor sub set value 
under HH environment
50
I
HL_EX PLAIN CL 
DUP HH
Correction value for color plain paper 
duplex external thermistor set value 
under HH environment
50
J
PLAIN CL DUP 
APP CNT HH
Correction value for color plain paper 
duplex applicable number of sheets 
under HH environment
50
K
HL_UM HEAVY 
BW DUP HH
Correction value for black and white 
heavy paper duplex upper thermistor 
main set value under HH environment
50
L
HL_LM HEAVY 
BW DUP HH
Correction value for HH environment 
black and white duplex lower 
thermistor main set value
50
A : 60
;
HL_UM PLAIN BW DUP LL
B : 60
;
HL_LM PLAIN BW DUP LL
C : 60
;
HL_US PLAIN BW DUP LL
D : 50
;
HL_EX PLAIN BW DUP LL
A:
SIMULATION NO.43-22
FUSER TEMP ADJUSTMENT (LL:DUP)
60
1
99
OK
TEST
CLOSE
E : 50
;
PLAIN BW DUP APP CNT LL
F : 55
;
HL_UM PLAIN CL DUP LL
G : 55
;
HL_LM PLAIN CL DUP LL
H : 55
;
HL_US PLAIN CL DUP LL
I : 50
;
HL_EX PLAIN CL DUP LL
J : 50
;
PLAIN CL DUP APP CNT LL
K : 60
;
HL_UM HEAVY BW DUP LL
L : 60
;
HL_LM HEAVY BW DUP LL
M
HL_US HEAVY 
BW DUP HH
Correction value for black and white 
heavy paper duplex upper thermistor 
sub set value under HH environment
50
N
HL_EX HEAVY 
BW DUP HH
Correction value for black and white 
heavy paper duplex external 
thermistor set value under HH 
environment
50
O
HEAVY BW DUP 
APP CNT HH
Correction value for black and white 
heavy paper duplex applicable 
number of sheets under HH 
environment
50
P
HL_UM HEAVY 
CL DUP HH
Correction value for color heavy paper 
duplex upper thermistor main set 
value under HH environment
50
Q
HL_LM HEAVY 
CL DUP HH
Correction value for HH environment 
black and white heavy paper duplex 
lower thermistor main set value
50
R
HL_US HEAVY 
CL DUP HH
Correction value for color heavy paper 
duplex upper thermistor sub set value 
under HH environment
50
S
HL_EX HEAVY 
CL DUP HH 
Correction value for color heavy paper 
duplex external thermistor set value 
under HH environment
50
T
HEAVY CL DUP 
APP CNT HH
Correction value for color heavy paper 
duplex applicable number of sheets 
under HH environment
50
Item
Default 
value
A : 50
;
HL_UM PLAIN BW DUP HH
B : 50
;
HL_LM PLAIN BW DUP HH
C : 50
;
HL_US PLAIN BW DUP HH
D : 50
;
HL_EX PLAIN BW DUP HH
A:
SIMULATION NO.43-23
FUSER TEMP ADJUSTMENT (HH: DUP)
50
1
99
OK
TEST
CLOSE
E : 50
;
PLAIN BW DUP APP CNT HH
F : 50
;
HL_UM PLAIN CL DUP HH
G 50
;
HL_LM PLAIN CL DUP HH
H 50
;
HL_US PLAIN CL DUP HH
I : 50
;
HL_EX PLAIN CL DUP HH
J : 50
;
PLAIN CL DUP APP CNT HH
K : 50
;
HL_UM HEAVY BW DUP HH
L : 50
;
HL_LM HEAVY BW DUP HH
Page of 127