DOWNLOAD Sharp MX-5500N / MX-6200N / MX-7000N (serv.man46) Service Manual ↓ Size: 3.61 MB | Pages: 127 in PDF or view online for FREE

Model
MX-5500N MX-6200N MX-7000N (serv.man46)
Pages
127
Size
3.61 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Simulation
File
mx-5500n-mx-6200n-mx-7000n-sm46.pdf
Date

Sharp MX-5500N / MX-6200N / MX-7000N (serv.man46) Service Manual ▷ View online

MX-7000N  SIMULATION  7 – 53
 
44-6
Purpose
Adjustment
Function (Purpose) Used to execute the high density process
correction compulsorily.
Section
Operation/Procedure
Press [EXECUTE] key.
In case of a normal completion, the result is saved.
In case of an abnormal completion, "ERROR" is displayed. (Refer
to the table below.)
 
44-9
Purpose
(Do not use in the market.)
Function (Purpose) Used to check data of correction results in
the image forming section.
Section
Process (Photoconductor/Developing/
Transfer/Cleaning)
Operation/Procedure
G
BIAS_CL 
STANDARD DIF
Bias (for color) reference 
calculation difference
0
H
BIAS_BK 
STANDARD DIF
Bias (for black) reference 
calculation difference
0
I
BIAS_BW 
STANDARD DIF
Reference calculation difference 
in high speed mode
0
J
BIAS PATCH 
INTERVAL
Patch bias output interval
60
K
BIAS_PATCH BW 
INTERVAL
BW patch bias output interval
45
L
Y_PAT TARGET ID
Patch density standard value 
(yellow)
115
M
M_PAT TARGET ID
Patch density standard value 
(magenta)
130
N
C_PAT TARGET ID
Patch density standard value 
(cyan)
120
O
K_PAT TARGET ID
Patch density standard value 
(black)
7
P
BW_PAT TARGET 
ID
BW process control execution BK 
target
7
Q
HV BK_GROUND 
LIMIT
Surface light reception effective 
area value at the patch position
29
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
K_HV_ERR
K high density process control abnormality
C_HV_ERR
C high density process control abnormality
M_HV_ERR
M high density process control abnormality
Y_HV_ERR
Y high density process control abnormality
TIMEOUT_ERR
Time out
Item
Default 
value
A : 98
;
PCS_CL TARGET
B : 155
;
PCS_K TARGET
C : 21
;
LED_CL OUTPUT
D : 21
;
LED_K OUTPUT
A:
SIMULATION NO.44-04
PROCON INITIAL DENSITY SETUP
98
1
255
OK
TEST
CLOSE
E :
4
;
POS ADJUSTMENT LIMIT
F : 255
;
BELT GROUND DIF
G :
0
;
BIAS_CL STANDARD DIF
H :
0
;
BIAS_BK STANDARD DIF
I :
0
;
BIAS_BW STANDARD DIF
J : 60
;
BIAS PATCH INTERVAL
K : 45
;
BIAS_PATCH BW INTERVAL
L : 115
;
Y_PAT TARGET ID
SIMULATION NO.44-06
TEST
PROCON COMPULSORY EXECUTION
EXECUTE
CLOSE
PRESS [EXECUTE] TO START
Mode
Item
Default 
value
CPY/
PRN
BLACK_P: GB ***/***  
DV ***/***
High density process 
control
GB/DV data
GB: 620 (K)
635 (CMY)
DV: 450
CYAN_P: GB ***/***  
DV ***/***
MAGENTA_P: GB ***/***  
DV ***/***
YELLOW_P: GB ***/***  
DV ***/***
CPY/
PRN
BLACK_N: GB ***/***  
DV ***/***
High density normal 
(Medium speed)
GB/DV data
GB: 620 (K)
635 (CMY)
DV: 450
CYAN_N: GB ***/***  
DV ***/***
MAGENTA_N: GB ***/***  
DV ***/***
YELLOW_N: GB ***/***  
DV ***/***
BLACK_L: GB ***/***  
DV ***/***
High density normal 
(Low speed)
GB/DV data
GB: 585 (K)
600 (CMY)
DV: 420
CYAN_L: GB ***/***  
DV ***/***
MAGENTA_L: GB ***/***  
DV ***/***
YELLOW_L: GB ***/***  
DV ***/***
BLACK_H: GB ***/***  
DV ***/***
High density normal 
(High speed)
GB/DV data
GB: 690
DV: 450
OTHER
TN HUD AREA
Toner concentration 
humidity area
9
TN HUD DATA
Toner concentration 
humidity AD value
0
TC TMP AREA
Transfer temperature 
area
4
TC TMP DATA
Transfer temperature 
AD value
0
TC HUD AREA
Transfer humidity 
area
4
TC HUD DATA
Transfer humidity AD 
value
0
MD HUD AREA
Membrane decrease 
humidity area
9
MD HUD DATA
Membrane decrease 
humidity AD value
0
MD K STEP  
Drum membrane 
decrease correction 
STEP
0
MD C STEP  
MD M STEP  
MD Y STEP  
MD K DRUM COUNTER
Drum travelling 
distance
0
MD C DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
MD K REVISE(VG): 
L *** M *** H***
Drum membrane 
decrease grid voltage 
correction
0
MD C REVISE(VG): 
L *** M *** 
MD M REVISE(VG): 
L *** M *** 
MD Y REVISE(VG): 
L *** M *** 
MX-7000N  SIMULATION  7 – 54
 
44-12
Purpose
(Do not use in the market.)
Function (Purpose) Used to check the sampling toner image
patch density data in the image density cor-
rection.
Section
Image process (Photoconductor/Develop-
ing)
Operation/Procedure
 
44-13
Purpose
Adjustment/Setting
Function (Purpose) Used to adjust the color image sensor. 
Section
Operation/Procedure
For details of the procedures, refer to [ADJ 7A] in [6] ADJUST-
MENTS.
OTHER
MD K REVISE(LD): 
L *** M *** H ***
Drum membrane 
decrease laser power 
voltage correction 
0
MD C REVISE(LD): 
L *** M ***
MD M REVISE(LD): 
L *** M ***
MD Y REVISE(LD): 
L *** M ***
MD K REVISE(HV): 
L *** M *** H ***
High density 
membrane decrease 
environment GB 
correction 
0
MD C REVISE(HV): 
L *** M ***
MD M REVISE(HV): 
L *** M ***
MD Y REVISE(HV): 
L *** M ***
MD K REVISE(CP): 
L *** M *** H ***
Drum membrane 
decrease 
environment grid 
voltage correction
0
MD C REVISE(CP): 
L *** M ***
MD M REVISE(CP): 
L *** M ***
MD Y REVISE(CP): 
L *** M ***
MD K REVISE COL (DL): 
L *** M ***
Drum membrane 
decrease discharge 
light quantity 
correction
70
MD C REVISE COL (DL): 
L *** M ***
MD M REVISE COL (DL): 
L *** M ***
MD Y REVISE COL (DL): 
L *** M ***
MD K REVISE BW (DL): 
L *** M *** H ***
80
MD K REVISE COL 
(DL EV): L *** M ***
Drum membrane 
decrease 
environment 
discharge light 
quantity correction
0
MD C REVISE COL 
(DL EV): L *** M ***
MD M REVISE COL 
(DL EV): L *** M ***
MD Y REVISE COL 
(DL EV): L *** M ***
MD K REVISE BW 
(DL EV): L *** M *** H ***
DESTINATION 
Main unit side 
destination 
MODEL TYPE 
Main unit model type
0
CRUM DEST_K
CRUM destination
CRUM DEST_C
CRUM DEST_M
CRUM DEST_Y
CRUM DEST_K2
PROCON COUNT HV
High density process 
control execution 
number
0
PROCON COUNT HT
Half tone process 
control execution 
number
0
Mode
Item
Default 
value
Item
Default 
value
CARB  DATA
Calibration plate sensor value
108
SEAL ADJ DATA
Jig patch seal sensor value
108
ADK_SL(K)
Developing characteristics gradient 
coefficient
0
ADK_INT(K)
Developing characteristics intercept 
coefficient
0
ID(K)
Sensor target value set value
0
ID(CMY)
Color sensor target set value
0
Item
Default 
value
A
PCS_CL CARB OUT
Calibration plate sensor value
108
B
PCS_CL DARK
Color dark voltage
0
C
PCS_CL LED ADJ
Color sensor light emitting 
quantity adjustment value
21
OTHER
SIMULATION NO.44-09
TEST
PROCON DATA DISP (PROCON / NORMAL(M) / NORMAL(L) / NORMAL(H))
CLOSE
BLACK_P
: GB_ 230/630 DV_ 0/620
CYAN_P
: GB_ 230/630 DV_ 0/635
MAGENTA_P : GB_ 230/630 DV_ 0/635
YELLOW_P : GB_ 230/630 DV_ 0/635
1/1
CPY/PRN
BLACK_N
: GB_ 230/600 DV_ 0/620
BLACK_L
: GB_ 230/600 DV_ 0/585
CYAN_N
: GB_ 230/600 DV_ 0/635
MAGENTA_N : GB_ 230/600 DV_ 0/635
YELLOW_N : GB_ 230/600 DV_ 0/635
CYAN_L
: GB_ 230/600 DV_ 0/600
MAGENTA_L : GB_ 230/600 DV_ 0/600
YELLOW_L : GB_ 230/600 DV_ 0/600
BLACK_H
: GB_ 230/600 DV_ 0/600
PATCH
TARGET
SIMULATION NO.44-12
TEST
PATCH/TARGET DATA DISPLAY
CLOSE
SEAL ADJ DATA : 108
ADK_SL(K)
: 0.00
ADK_INT(K)
: 0.0
CARB DATA
: 108
1/1
TARGET(K)
: 0.00
TARGET(C)
: 0.00
TARGET(M)
: 0.00
TARGET(Y)
: 0.00
MX-7000N  SIMULATION  7 – 55
C: Standard value 60 
± 10 after adjustment
 
44-14
Purpose
Adjustment, setting, operation data check
Function (Purpose) Used to check the output level of the tem-
perature/humidity sensor. 
Section
Image process (Photoconductor/Develop-
ing)
Operation/Procedure
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
 
44-16
Purpose
(Do not use in the market.)
Function (Purpose) Used to check the toner density control
data.
Section
Operation/Procedure
TH_UM
Fusing upper thermistor main A/D value (differential) 
(temperature 
°C)
TH_UM_AD1
Fusing upper thermistor main compensation sensor 
temperature value/AD value (compensation) 
(temperature 
°C)
TH_UM_AD2
Fusing upper thermistor main sensor AD value 
(detection)
TH_LM
Fusing lower thermistor main A/D value (temperature 
°C)
TH_US
Fusing upper thermistor sub A/D value (temperature 
°C)
TH_EX1
Fusing external thermistor A/D value (temperature 
°C)
TH_EX2
Fusing external thermistor 2 A/D value (temperature 
°C)
TH_M
Manual feed temperature sensor A/D value 
(temperature 
°C)
HUD_M
Manual feed humidity sensor A/D value (humidity %)
TH1_LSU
LSU thermistor 1 A/D value (temperature 
°C)
DV_HUM
Developing tank humidity detection 
DV_TH
Developing tank temperature detection 
SIMULATION NO.44-13
TEST
PATCH SEAL ADJUSTMENT
EXECUTE
PCS CL CARB OUT
108
:
PCS CL DARK
0
:
PCS CL LED ADJ
21
OK
:
1/1
CLOSE
SIMULATION NO.44-14
TEST
SENSOR DATA DISPLAY MONITOR
1/1
TH_UM
255deg / XXX
:
TH_LM
255deg / XXX
:
TH_US
255deg / XXX
:
TH_UM_AD1
255.0deg / XXX
:
TH_UM_AD2
XXX
:
TH_EX1
255deg / XXX
:
:
TH_EX2
255deg / XXX
TH_M
60.0deg / XXX
:
HUD_M
90.0% / XX
:
TH1_LSU
60.0deg / XX
90.0% / XXX
60.0deg / XX
:
DV_HUM
:
DV_TH
:
CLOSE
Item
Default 
value
TONER DEN_LT 
(M)
Medium speed toner density sensor 
output value (final value) (KCMY)
129
TONER DEN_ST 
(M)
Medium speed toner density reference 
value (including the correction value) 
(KCMY)
128
TONER DEN_LT 
(L)
Low speed toner density sensor output 
value (final value) (KCMY)
129
TONER DEN_ST 
(L)
Low speed toner density reference value 
(including the correction value) (KCMY)
128
TONER DEN_LT 
(H)
High speed toner density sensor output 
value (final value) (K)
129
TONER DEN_ST 
(H)
High speed toner density reference value 
(including the correction value) (K)
128
AUTO DEVE (M)
Automatic development adjustment value 
(middle speed)
128
ALL (M)
All correction reference value (middle 
speed) for automatic development 
adjustment value (KCMY)
AUTO DEVE (L)
Automatic development adjustment value 
(low speed)
ALL (L)
All correction reference value (low 
speed) for automatic development 
adjustment value (KCMY)
AUTO DEVE (H)
Automatic development adjustment value 
(high speed)
ALL (H)
All correction reference value (high 
speed) for the automatic development 
adjustment value (KCMY)
AREA
Correction value for environment area 
(KCMY)
0
HUD
Correction value for humidity change 
(KCMY)
PRINT RATE
Correction value for document print ratio 
(KCMY)
PROCON
Correction value for high density process 
control result (KCMY)
LIFE
Correction value for developer life 
(KCMY)
SENSITIVITY
Correction for toner density sensor 
sensitivity
500
AUTO DEVE VO 
(M)
Automatic development adjustment 
control voltage value (middle speed)
128
ALL VO (M)
Control voltage correction reference 
value (middle speed) (KCMY) for 
automatic development adjustment value
AUTO DEVE VO 
(L)
Automatic development adjustment 
control voltage adjustment (low speed)
ALL VO (L)
Control voltage correction reference 
value (low speed) (KCMY) for the 
automatic development adjustment value
AUTO DEVE VO 
(H)
Automatic development adjustment 
control voltage value (high speed)
ALL VO (H)
Control voltage correction reference 
value (high speed) (K) for the automatic 
development adjustment value
AREA VO
Control voltage correction value for the 
environment area
0
HUD VO
Humidity change control voltage 
correction value (KCMY)
PRINT RATE VO
Control voltage correction value (KCMY) 
for the document print rate
PROCON VO
Control voltage correction value (KCMY) 
for the high density process control result
LIFE VO
Control voltage correction voltage 
(KCMY) for the developer life
SENSITIVITY VO
Control voltage correction value (KCMY) 
for the toner density sensor sensitivity
500
ENV VO
Control voltage correction value (KCMY) 
under high humidity environment
0
AUTO DEVE 
AREA
Humidity change (KCMY) in automatic 
development adjustment
8
AREA
Current humidity display (KCMY)
MX-7000N  SIMULATION  7 – 56
 
44-21
Purpose
Adjustment/Setting
Function (Purpose) Used to set the half tone process control.
Section
Process
Operation/Procedure
Press [EXECUTE] key.
The process control reference value is registered. 
In case of a normal completion, the result is saved.
 
44-22
Purpose
(Do not use in the market.)
Function (Purpose) Used to check the toner patch image den-
sity level of each color in half tone image
forming section correction (process correc-
tion). 
Section
Operation/Procedure
 
44-24
Purpose
(Do not use in the market.)
Function (Purpose) Used to display the process control result. 
Section
Operation/Procedure
 
44-25
Purpose
(Do not use in the market.)
Function (Purpose) Used to set the initial conditions of the pro-
cess control half tone correction. 
Section
Operation/Procedure
 
44-26
Purpose
Adjustment/Setting
Function (Purpose) Used to execute the half tone process con-
trol compulsorily.
Section
Process
Operation/Procedure
Press [EXECUTE] key.
The process control is started compulsorily.
For the result of the process control compulsory execution, refer to
the table below.
SIMULATION NO.44-16
TEST
TONER CONTROL DATA DISPLAY
NEXT
TONER DEN_LT(M)
129
:
TONER DEN_ST(M)
128
:
TONER DEN_LT(L)
129
:
TONER DEN_ST(L)
128
:
1/1
K
M
Y
C
CLOSE
TONER DEN_LT(H)
129
:
TONER DEN_ST(H)
128
:
SIMULATION NO.44-21
TEST
HALF TONE PROCON STANDARD VALUE REGISTER
EXECUTE
CLOSE
TOUCH [EXECUTE] THEN EXECUTION START.
2ND STEP
1ST STEP
SIMULATION NO.44-22
TEST
HALF TONE CORRECT RESULT
CLOSE
1/1
PTK/BASE PTC PTM PTY
ID 1 : 255/255
255
255
255
ID 2 : 255/255
255
255
255
ID 3 : 255/255
255
255
255
ID 4 : 255/255
255
255
255
ID 5 : 255/255
255
255
255
Item
Default 
value
A
1ST PATCH
Half tone process control 1ST step No. 1 
patch print gradation 
40
B
2ND PATCH
Half tone process control 1ST step No. 2 
patch print gradation 
60
C
3RD PATCH
Half tone process control 1ST step No. 3 
patch print gradation 
80
D
4TH PATCH
Half tone process control 1ST step No. 4 
patch print gradation 
100
E
5TH PATCH
Half tone process control 1ST step No. 5 
patch print gradation 
255
COMPLETE
Normal completion 
INTERRUPTION
Compulsory interruption
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
[YMCK]
High density process control [YMCK] abnormality
CONNECTION_ERR
Communication abnormality
K
M
Y
C
SIMULATION NO.44-24
TEST
HALF TONE PROCON RESULT DISPLAY
CLOSE
[RIZE] 16
[SATURATE] 109
[STEP] 9.3
[EX-LOW]
A:
0.0
, B:
100.0
[LOW]
A: -0.013
, B: -0.569
, C:
107.444
[CONNECT] A:
0.0
, B:
0.0
1/1
NEXT
[MID]
A:
0.014
, B: -2.598
, C:
139.245
[HIGH]
A: -0.120
, B: -35.708
[CONNECT POINT] #1:100, #2: 86, #3: 86, #4: 25
A : 40
;
1ST PATCH
B : 60
;
2ND PATCH
C : 80
;
3RD PATCH
D : 100
;
4TH PATCH
A:
SIMULATION NO.44-25
HALF TONE PROCON INITIAL VALUE DISPLAY
40
0
255
OK
TEST
CLOSE
E : 255
;
5TH PATCH
K
C
M
Y
Page of 127