MX-5111N MX-PNX6A/B/C/D (PUNCH MODULE) 16 – 3
5)
Attach the front cover mounting fixture (Packed items) with the
fixing screws (Packed items).
Remove the screw of the finisher, and reuse it. Install it using
the reuse screw, and three fixing screws (Packed items) bun-
dled to punch unit.
fixing screws (Packed items).
Remove the screw of the finisher, and reuse it. Install it using
the reuse screw, and three fixing screws (Packed items) bun-
dled to punch unit.
6)
Open the front door of punch unit.
7)
Engage the pawls of the rear side of front cover (Packed
items), attach the front cover with the fixing screw (Packed
items).
items), attach the front cover with the fixing screw (Packed
items).
B. Connection of connector of the finisher and
punch unit
1)
Remove the fixing screws, and remove the rear cover.
2)
Connect two connectors of the finisher to the PWB of punch
unit, and fix the harness to the clamp.
unit, and fix the harness to the clamp.
C. Attaching the mylar
1)
Attach the guide mylar upper (Packed items) to the position
indicated in the figure.
indicated in the figure.
2
3
1
Corner reference
Reference
MX-5111N MX-PNX6A/B/C/D (PUNCH MODULE) 16 – 4
2)
Attach the guide mylar lower (Packed items) to the position
indicated in the figure.
indicated in the figure.
D. Install of the Connection fixture F/R
1)
Install the Connection fixture F (Packed items) to the main unit
with the fixing screws (Packed items).
with the fixing screws (Packed items).
2)
Install the Connection fixture R (Packed items) to the main unit
with the fixing screws (Packed items).
with the fixing screws (Packed items).
E. Check of the connected position of main unit
and finisher
1)
Engage the finisher that has installed punch unit to the main
unit, and temporarily fix.
* Insert the rail of the finisher unit into the rail reception fixture
unit, and temporarily fix.
* Insert the rail of the finisher unit into the rail reception fixture
of main unit, fix temporarily.
2)
Open the front door of punch unit.
3)
Check that the center of the screw hole of the punch unit is in
the range of specification of an oval hole of the mounting fix-
ture in front side of main unit.
the range of specification of an oval hole of the mounting fix-
ture in front side of main unit.
Paper exit port reference
Fixture reference
+1mm
+0.5mm
MX-5111N MX-PNX6A/B/C/D (PUNCH MODULE) 16 – 5
* When not the range of specification, progress to the proce-
dure of "F. Adjustment".
If the adjustment is not required, remove the screw from the
screw hole directly and push the caster into it until the instal-
lation fixing. (MX-FN11 only)
If the adjustment is not required, remove the screw from the
screw hole directly and push the caster into it until the instal-
lation fixing. (MX-FN11 only)
F. Adjustment
* Refer to the adjustment procedure of each finisher.
G. Install to main unit
1)
Engage the finisher that has installed punch unit to the main
unit.
unit.
2)
Open the front door of punch unit.
3)
Secure the main unit and the punch unit with the fixing screw
(Packed items of the MX-FN11).
(Packed items of the MX-FN11).
4)
Close the front door of punch unit.
5)
Install the fixing screw (Packed items of MX-FN11) on rear
side.
side.
6)
Install the rear cover of punch unit with the fixing screws.
1
: '11/Jul/25
1
MX-5111N MX-PNX6A/B/C/D (PUNCH MODULE) 16 – 6
7)
By using nippers, split the removed connector cover of the fin-
isher along the perforated line.
isher along the perforated line.
8)
Install the connector cover of the finisher and fix it with the fix-
ing screw.
ing screw.
H. Connection of connector to the main unit
1)
Connect two connectors of the finisher to the main unit, and
tighten the screws.
tighten the screws.
I. Punch position label attachment
1)
Attach the punch position label (Packed items of the MX-FN11)
to the position indicated in the figure.
For scanner
to the position indicated in the figure.
For scanner
For DSPF/RSPF
J. Turn on the power of the main unit
1)
Connect the power plug of the machine to the power outlet,
and turn ON the main power switch and the operation panel
power switch.
and turn ON the main power switch and the operation panel
power switch.
DSPF
RSPF
R2.5 connection line
Edge line R 2.5
CAUTION
Cleaning of the document scan section
When streaks appear on copy or scan
images, open the automatic document
feed unit and clean the document scan
section with the glass cleaner (accessory).
images, open the automatic document
feed unit and clean the document scan
section with the glass cleaner (accessory).