[24] MX-EB11 (ENHANCED COMPRESSION KIT)
1.  Unpacking
A. Packed items check
2.  Installation
NOTE: Before installation, be sure to turn both the operation and
main power switches off and disconnect the power plug
from the power outlet. Make double sure that the data lamp
on the operation panel does not light up or blink when per-
forming installation. 
A. Pull out the control PWB.
• If cables are connected to the control PWB unit, remove all
cables.
1)
Push the location indicated in the illustration to unlock, and
remove the ozone filter cover from the right rear cabinet.
2)
Remove the screw from the right rear cabinet and remove the
right rear cabinet.
3)
Remove the two screws from the control PWB unit.
4)
Pull out the control PWB unit.
• If the fax box unit is installed, carry out steps 5), 6), and
7) additionally.
5)
Remove the screw and remove the snap band.
6)
Remove the interface cable from the frame.
7)
Remove the connector.
8)
Pull out and remove the control PWB unit.
B. Scanner function expansion PWB installation
1)
Connect the scanner function expansion PWB (Packed items)
to the MFP control PWB, and fit it with the screw (Packed
items).
No.
Name
Quantity
1
Scanner function expansion PWB
1
2
Screw
2
1
2
2
3
3
4
1
2
MX-5111N  MX-EB11 (ENHANCED COMPRESSION KIT)  24 – 2
C. Reattach the control PWB and the right rear 
cabinet.
• If the fax box unit is installed, carry out steps 1), 2), and 3)
additionally.
1)
Connect the interface cable to the control PWB unit.
2)
Push the interface cable into the recessed portion of the sheet
metal on the control PWB unit.
3)
Attach the snap band to the sheet metal of the control PWB
unit.
4)
Push the control PWB unit into the main unit.
5)
Secure the unit with the two screws.
6)
Fit the interface cable into the right rear cabinet cover.
7)
Attach the right rear cabinet cover to the main unit.
At this time, check that the four hooks are properly fitted to the
main unit.
8)
Secure the right rear cabinet with the screw.
9)
Attach the ozone filter cover to the main unit.
• Reconnect the cables that have been removed in step A to the
original positions of the control PWB unit.
D. Turn ON the power of the main unit
1)
Connect the power plug of the machine to the power outlet,
and turn ON the main power switch and the operation panel
power switch.
E. Confirmation of connection
1)
Execute SIM22-10 to check to confirm that the combined
machine recognizes the MX-EB11.
Hook 1 Hook 2
Hook 3
Hook 4
6
8
7
MX-5111N  MX-FR33/FR33U (DATA SECURITY KIT)  25 – 1
MX-5111N
Service Manual
 
[25] MX-FR33/FR33U (DATA SECURITY KIT)
1.  Unpacking
A. Packed items check
2.  Installation
NOTE: Before installing the data security kit, be sure to perform
backup of data stored in the memory (including HDD) of the
main unit.
When the data security kit is installed, all the job data
stored in the memory (including HDD) of the main unit will
be lost.
NOTE: If the LINE indicator or the DATA indicator for the printer
and image transmission on the operation panel is lit or
blinking, data that has not been processed remains in the
memory of the main unit (including HDD). Output or trans-
mit all the data to clear the data remaining in the main unit
and then start installation. 
NOTE: Before installation, be sure to turn both the operation and
main power switches off and disconnect the power plug
from the power outlet. Make double sure that the data lamp
on the operation panel does not light up or blink when per-
forming installation. 
A. Pull out the control PWB.
• If cables are connected to the control PWB unit, remove all
cables.
1)
Push the location indicated in the illustration to unlock, and
remove the ozone filter cover from the right rear cabinet.
2)
Remove the screw from the right rear cabinet and remove the
right rear cabinet.
3)
Remove the two screws from the control PWB unit.
4)
Pull out the control PWB unit.
• If the fax box unit is installed, carry out steps 5), 6), and
7) additionally.
5)
Remove the screw and remove the snap band.
6)
Remove the interface cable from the frame.
7)
Remove the connector.
8)
Pull out and remove the control PWB unit.
B. Program ROM attachment
1)
Attach the program ROM (Packed items) to the OPT ROM slot
of the MFP control PWB.
No.
Name
Quantity
1
Program  ROM
1
2
Product key sheet
1
3
User manual (CD-ROM)
1
4
Firmware program (USB memory)
1
1
2
3
4
2
3
3
4
OPT ROM
MX-5111N  MX-FR33/FR33U (DATA SECURITY KIT)  25 – 2
2)
Set the BOOT SW on the left upper side of the MFP control
PWB to OFF.
C. Reattach the control PWB and the right rear 
cabinet.
• If the fax box unit is installed, carry out steps 1), 2), and 3)
additionally.
1)
Connect the interface cable to the control PWB unit.
2)
Push the interface cable into the recessed portion of the sheet
metal on the control PWB unit.
3)
Attach the snap band to the sheet metal of the control PWB
unit.
4)
Push the control PWB unit into the main unit.
5)
Secure the unit with the two screws.
6)
Fit the interface cable into the right rear cabinet cover.
7)
Attach the right rear cabinet cover to the main unit.
At this time, check that the four hooks are properly fitted to the
main unit.
8)
Secure the right rear cabinet with the screw.
9)
Attach the ozone filter cover to the main unit.
• Reconnect the cables that have been removed in step A to the
original positions of the control PWB unit.
D. Turn ON the power of the main unit
1)
Connect the power plug of the machine to the power outlet,
and turn ON the main power switch and the operation panel
power switch.
E. Firmware update procedures
(1) Entering the boot mode
1)
When the power is turned ON, the main program error is dis-
played.
2)
The above error message is displayed for 10 sec. Then the fol-
lowing message is displayed.
3)
The machine enters the boot mode which indicates that there
is an error in the main program.
Hook 1 Hook 2
Hook 3
Hook 4
6
8
7
Main Program Error!!
Emergency Prog Init
Please wait
Version Check
IcM:UNUSUAL