FIRMWARE UPDATE 
SHARP  
 
36
 
 
 
5.  Select the required firmware that requires updating - Press Execute & Yes to commence the update. 
 
Note: If all firmware (including peripherals) require updating, select ALL (as shown):-  
 
 
 
6.  The firmware update progress (and remaining time) should now be displayed:- 
 
 
 
7.  Once the firmware update has completed successfully, the MFP device will automatically reboot. 
 
Firmware update via USB memory Device is complete. 
 
 
SHARP
 
FIRMWARE UPDATE
 
 
37
 
NETWORK CONNECTION (MFP WEB PAGE) 
 
1.  Open a web browser and enter the following URL :- 
 
http://ipaddress/service_login.html   or  http://ipaddress/service_account.html 
 
Example: http://192.168.0.156/service_login.html 
 
Note:  If User Authentication (username & password) is enabled, open the device webpage and  
 
           “login” using the service username and password (as below):- 
 
 
 
2.  Select/Enter the “Service” Username and Password to access the Service Webpage and click Login:- 
Default  
Username:  service 
 
 
 
 
 
 
Password: 
service 
 
 
 
3.  When the service webpage opens, click Update of Firmware:- 
 
 
 
FIRMWARE UPDATE 
SHARP  
 
38
 
4.  Click Browse to navigate to the location of the updated firmware file and select Open:- 
 
 
 
5.  Press Execute to start the firmware update. 
 
Note: Once the machine has entered “service download mode”, the update will commence and the  
 
           progress will be displayed. 
 
 
 
6.  When the firmware upgrade is complete, click Reboot to execute a remote restart of the machine. 
 
 
 
Firmware Upgrade is complete
SHARP
 
FIRMWARE RECOVERY
 
 
39
 
In the event of a power failure during a firmware update, the device may fail to “reboot” because of 
corrupted firmware. Using the CN Update procedure described below, this function is used to 
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and 
various options by means of a USB memory. 
 
MENU KEY REFERENCE: 
 
The following five keys are used to perform firmware recovery mode. For MX-3050-6070N series, touch the 
LCD panel within the area shown below to select the desired key:- 
 
 
 
 
 
 
    
     [UP]                                 [BACK] 
 
 
 
 
 
 
 
              
 [DOWN]   
 
         [OK] 
     [MENU] 
 
CN UPDATE - Firmware Recovery Procedure:- 
 
1.  Power off the MFP and remove the MFP Rear Cabinet & Screws. 
 
2.  Set the SCN-MFP CONTROL PWB UPDATE DIP-SW to ON:- 
 
 
 
Note: If a Boot failure has occurred, replace the Boot FlashROM. 
 
3.  Install the USB Memory containing the MX-3060/3070/3560/3570/4060/4070/5070/6070N firmware 
into the USB slot. 
Note: The Firmware file (*.sfu) must only be saved on the main or one level lower directory of the 
           USB Memory. 
 
4.  Power ON the MFP device - the UPDATE PROGRAM INIT PLEASE WAIT boot menu should appear  
after approx 10 seconds, followed by VERSION CHECK CONFIG: information:-. 
 
 
 
 
 
Version Check 
  Conf: 00050000 
Update Program Init 
Please wait
 