Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man2) Handy Guide ▷ View online
FIRMWARE UPDATE
SHARP
36
5. Select the required firmware that requires updating - Press Execute & Yes to commence the update.
Note: If all firmware (including peripherals) require updating, select ALL (as shown):-
6. The firmware update progress (and remaining time) should now be displayed:-
7. Once the firmware update has completed successfully, the MFP device will automatically reboot.
Firmware update via USB memory Device is complete.
SHARP
FIRMWARE UPDATE
37
NETWORK CONNECTION (MFP WEB PAGE)
1. Open a web browser and enter the following URL :-
http://ipaddress/service_login.html or http://ipaddress/service_account.html
Example: http://192.168.0.156/service_login.html
Note: If User Authentication (username & password) is enabled, open the device webpage and
“login” using the service username and password (as below):-
2. Select/Enter the “Service” Username and Password to access the Service Webpage and click Login:-
Default
Username: service
Password:
service
3. When the service webpage opens, click Update of Firmware:-
FIRMWARE UPDATE
SHARP
38
4. Click Browse to navigate to the location of the updated firmware file and select Open:-
5. Press Execute to start the firmware update.
Note: Once the machine has entered “service download mode”, the update will commence and the
progress will be displayed.
6. When the firmware upgrade is complete, click Reboot to execute a remote restart of the machine.
Firmware Upgrade is complete
SHARP
FIRMWARE RECOVERY
39
In the event of a power failure during a firmware update, the device may fail to “reboot” because of
corrupted firmware. Using the CN Update procedure described below, this function is used to
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and
various options by means of a USB memory.
MENU KEY REFERENCE:
corrupted firmware. Using the CN Update procedure described below, this function is used to
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and
various options by means of a USB memory.
MENU KEY REFERENCE:
The following five keys are used to perform firmware recovery mode. For MX-3050-6070N series, touch the
LCD panel within the area shown below to select the desired key:-
LCD panel within the area shown below to select the desired key:-
[UP] [BACK]
[DOWN]
[OK]
[MENU]
CN UPDATE - Firmware Recovery Procedure:-
1. Power off the MFP and remove the MFP Rear Cabinet & Screws.
2. Set the SCN-MFP CONTROL PWB UPDATE DIP-SW to ON:-
Note: If a Boot failure has occurred, replace the Boot FlashROM.
3. Install the USB Memory containing the MX-3060/3070/3560/3570/4060/4070/5070/6070N firmware
into the USB slot.
Note: The Firmware file (*.sfu) must only be saved on the main or one level lower directory of the
USB Memory.
USB Memory.
4. Power ON the MFP device - the UPDATE PROGRAM INIT PLEASE WAIT boot menu should appear
after approx 10 seconds, followed by VERSION CHECK CONFIG: information:-.
Version Check
Conf: 00050000
Conf: 00050000
Update Program Init
Please wait
Please wait
Click on the first or last page to see other MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man2) service manuals if exist.