Copying Equipment / Phoenix Handy Guide MX-XX60 MX-XX70 Updated Dec 16 Note Handy Guides are not a Substitute for the Service Manual
File
mx-3050n-mx-3060n-mx-3070n-mx-3550n-mx-3560n-mx-35.pdf
Date

Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man2) Handy Guide ▷ View online

SHARP
 
FIRMWARE UPDATE
 
 
37
 
NETWORK CONNECTION (MFP WEB PAGE) 
 
1.  Open a web browser and enter the following URL :- 
 
http://ipaddress/service_login.html   or  http://ipaddress/service_account.html 
 
Example: http://192.168.0.156/service_login.html 
 
Note:  If User Authentication (username & password) is enabled, open the device webpage and  
 
           “login” using the service username and password (as below):- 
 
 
 
2.  Select/Enter the “Service” Username and Password to access the Service Webpage and click Login:- 
Default  
Username:  service 
 
 
 
 
 
 
Password: 
service 
 
 
 
3.  When the service webpage opens, click Update of Firmware:- 
 
 
 
FIRMWARE UPDATE 
SHARP  
 
38
 
4.  Click Browse to navigate to the location of the updated firmware file and select Open:- 
 
 
 
5.  Press Execute to start the firmware update. 
 
Note: Once the machine has entered “service download mode”, the update will commence and the  
 
           progress will be displayed. 
 
 
 
6.  When the firmware upgrade is complete, click Reboot to execute a remote restart of the machine. 
 
 
 
Firmware Upgrade is complete
SHARP
 
FIRMWARE RECOVERY
 
 
39
 
In the event of a power failure during a firmware update, the device may fail to “reboot” because of 
corrupted firmware. Using the CN Update procedure described below, this function is used to 
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and 
various options by means of a USB memory. 
 
MENU KEY REFERENCE: 
 
The following five keys are used to perform firmware recovery mode. For MX-3050-6070N series, touch the 
LCD panel within the area shown below to select the desired key:- 
 
 
 
 
 
 
    
     [UP]                                 [BACK] 
 
 
 
 
 
 
 
              
 [DOWN]   
 
         [OK] 
     [MENU] 
 
CN UPDATE - Firmware Recovery Procedure:- 
 
1.  Power off the MFP and remove the MFP Rear Cabinet & Screws. 
 
2.  Set the SCN-MFP CONTROL PWB UPDATE DIP-SW to ON:- 
 
 
 
Note: If a Boot failure has occurred, replace the Boot FlashROM. 
 
3.  Install the USB Memory containing the MX-3060/3070/3560/3570/4060/4070/5070/6070N firmware 
into the USB slot. 
Note: The Firmware file (*.sfu) must only be saved on the main or one level lower directory of the 
           USB Memory. 
 
4.  Power ON the MFP device - the UPDATE PROGRAM INIT PLEASE WAIT boot menu should appear  
after approx 10 seconds, followed by VERSION CHECK CONFIG: information:-. 
 
 
 
 
 
Version Check 
  Conf: 00050000 
Update Program Init 
Please wait
 
FIRMWARE RECOVERY 
SHARP  
 
40
 
5.  Select FIRM UPDATE Mode by using the [Menu] & [Back] keys. Using the [UP] and [DOWN] keys, 
navigate and select the required firmware SFU. 
 
 
 
 
Note: 
Use the [OK] key when a directory name is selected to browse through to the sub folder(s) or  
the [BACK] key to return to the parent folder(s). 
 
6.  Press [OK] to commence Firmware Update. – It may take approx. 1-2 minutes to read the SFU file. 
After reading is completed, the firmware update (writing) will commence automatically. 
 
 
 
 
 
Note:   
The abbreviated name/location of the firmware that is being updated will appear in the upper  
right corner. 
 
7.  If the firmware upgrade completes successfully, RESULT OK will be displayed:- 
 
 
 
 
Result: NG = Update failed;    Result: Not Update = Update is not executed. 
 
8.  Power off the MFP and return the SCN-MFP CONTROL PWB UPDATE DIP-SW to OFF (Default):- 
 
 
 
9.  Power ON the MFP, and confirm that the machine boots up normally. 
 
10. Power OFF the MFP and refit the MFP PWB Rear Cabinet & Screws. 
 
11. Check/confirm the firmware version using SIM 22-05. 
 
CN UPDATE - Firmware Recovery Procedure is now complete. 
 
 
 
Firm Update 
> 0300Z100.sfu
 
Firm Update 
    Reading Data
 
Firm Update              IcuM 
    Writing Data
 
Firm Update           IcuM 
    Result  :  OK
 
Firm Update 
    From USB Memory
 
Page of 82
Display