DOWNLOAD Sharp MX-2630 (serv.man6) Service Manual ↓ Size: 5.04 MB | Pages: 75 in PDF or view online for FREE

Model
MX-2630 (serv.man6)
Pages
75
Size
5.04 MB
Type
PDF
Document
Handy Guide
Brand
Device
Copying Equipment / Handy Guide MX2630N Sphinx
File
mx-2630-sm6.pdf
Date

Sharp MX-2630 (serv.man6) Handy Guide ▷ View online

SHARP
 
COLOUR BALANCE ADJUSTMENT
 
 
MX-2630N Handy Guide NOV’17 
Sharp Office Solutions Group 
Page 13
/75 
 
Troubleshooting - Standard Colour Calibration procedure when experiencing colour image quality issues: 
 
 
Sim 22-06  
Print and check consumable life, trouble & jam history. 
 
Remove all Process Units, DV Units & MC Units and perform a thorough clean. 
 
Clean the LSU Slit Glass 
 
Clean the optical section. 
 
Clean the ID sensors. 
 
Sim 22-05 
Check firmware version and update to the latest version. 
 
Sim 44-27  
Clear Half Tone Process Correction. 
 
 
This simulation clears the previous high voltage compensation applied to DV&GB bias in order 
 
 
to maintain a good image density level. 
 
Sim 61-04 
LSU Skew Adjustment. 
 
 
Tolerance is approx. 1.5mm when measuring two diagonals. 
 
Sim 50-10 
LSU BK Magnification. 
 
 
Check LSU BK Magnification - Inside dimension of the printed halftone must be 240±0.5mm 
 
 
Sim 61-13 
Laser F/R Evenness Correction Data Clear. 
Sim 61-11 
Laser F/R Evenness Correction Adjustment. 
 
 
Use auto adjustment first. If the result is not satisfying, repeat before performing manual  
 
 
adjustment. 
 
Sim 50-22 
Drum Phase & Colour Registration  
Adjustment. 
 
 
This simulation must be executed when the drums are replaced. Check for any F2-50/51/52/53 
 
 
(Drum Phase) trouble before proceeding. 
 
Sim 8-01 
Check DV Bias. 
 
 
Check DVB output value on label attached to MC PWB is the same as Sim8-01 settings. 
 
Sim 8-02 
Check GRID Bias. 
 
 
Check GB output value on label attached to MC PWB is the same as Sim8-02 settings. 
 
Sim 63-03  
CCD Calibration - use Adjustment Chart 
UKOG-0356FCZZ
 
 
To ensure the machine can read correct values from the print patterns produced during colour 
 
 
calibration. 
 
Sim 63-11 
Default Engine Colour Balance Setting. 
 
Sim 67-26 
Default Printer Colour Balance Setting. 
 
Sim 63-08 
Reset Service & User Colour Balance for COPY mode 
 
 
Clears the previous Service & Customer colour balance settings. 
 
Sim 67-28 
Reset Service & User Colour Balance for PRINTER mode. 
 
 
Clears the previous Service & Customer colour balance settings. 
 
Sim 46-74 
Colour Calibration for COPY & PRINT modes. 
 
 
Always select Factory mode unless Service colour balance is registered for customising colour  
 
 
output. 
 
Settings (Admin) -> Image Quality Adjustment -> Auto Colour Calibration for Copy. 
Settings (Admin) -> Image Quality Adjustment -> Auto Colour Calibration for Print. 
To reproduce colour consistently, the end user may need to conduct user calibration on a regular basis. For 
clients who produce large volume prints, it is recommended to perform user calibration before the long run.
 
 
Check colour output for both Copy & Print modes. 
 
MINIMUM CALL PROCEDURE 
SHARP  
 
Page 14
/75
 
MX-2630N Handy Guide NOV’17 
Sharp Office Solutions Group
 
 
MINIMUM CALL PROCEDURE: 
 
SAMPLE PRINT/COPY: 
 
 
Sim 64-01 
A:11, B:2, C:2, D:255. 
 
Sim 64-05 
A:3, B:255 
 
SERVICE CHART (Colour & B/W Mode) 
 
 
 
MACHINE DATA [BEFORE]: 
 
 
Sim 22-03 
Check Jam History 
 
Sim 22-04 
Check Trouble Code History 
 
Sim 22-05 
Check ROM Versions 
 
 
 
Sim 22-06 
Print Patterns No 1 & 3 
 
Sim 23-02 
Print Jam/Trouble History 
 
MAINTENANCE LIST 
Check 
Clean  Replace* 
Exterior 
 
 
 
Operation Panel 
 
 
 
Mirror (Optical Section) 
 
 
 
SPF Glass 
 
 
 
Document Glass (OC) 
 
 
 
LSU Glass 
 
 
 
MC Cleaning (Sim6-04 MC Cleaning Operation) 
 
 
 
PTC Cleaning (Sim6-04 PTC Cleaning Operation) 
 
 
 
Paper Pick-Up, Feed & Separation Rollers (Tray) – Sim22-03 Jam History 
 
 
 
10 
Paper Pick-Up, Feed & Separation Rollers (Bypass) – Sim22-03 Jam History 
 
 
 
11 
Main Charger (Sim 22-13 Life Counter) 
 
 
 
12 
OPC Drum (Sim 22-13 Life Counter) 
 
 
 
13 
Drum Cleaning Blade (Sim 22-13 Life Counter) 
 
 
 
14 
Developer (Sim 22-13 Life Counter) 
 
 
 
15 
Transfer Belt (Sim 22-13 Life Counter) 
 
 
 
16 
Transfer Blade (Sim 22-13 Life Counter) 
 
 
 
17 
Cleaning Roller (Sim 22-13 Life Counter) 
 
 
 
18 
Fusing Unit (Sim 22-13 Life Counter) 
 
 
 
19 
Image Density Sensor 
 
 
 
 
FIRMWARE UPGRADE: 
 
SIM 49-01 
 
SIM 49-03 
 
SIM 49-05 
 
SIM 49-06 
 
IMAGE QUALITY ADJUSTMENTS: 
 
SIM 61-11 
 
SIM 50-22 
 
SIM 46-74 
 
 
 
IMAGE CHECK [PRINT & COPY]: 
 
 
SIM 64-01 
 
SIM 64-05 
 
SERVICE CHART COPY 
 
 
MACHINE DATA [FINISH]: 
 
SIM 22-06 (ALL) 
 
 
 
 
 
 
 
* For Maintenance Item replacement (Simulation Counter reset), refer to the following Maintenance section  
   within this guide.
 
SHARP
 
MAINTENANCE
 
 
MX-2630N Handy Guide NOV’17 
Sharp Office Solutions Group 
Page 15
/75 
 
MAINTENANCE INDICATIONS: 
 
DK 
Black Drum Counter has reached the specified life. 
Replace Black OPC Drum 
PROCESS
 S
ECTION
 
 
DC 
Cyan Drum Counter has reached the specified life. 
Replace Cyan OPC Drum 
 
DM 
Magenta Drum Counter has reached the specified life. 
Replace Magenta OPC Drum 
 
DY 
Yellow Drum Counter has reached the specified life. 
Replace Yellow OPC Drum  
 
MCK
 
Black Main Charge Counter has reached the specified life. 
Replace K Main Charge Kit 
 
MCC
 
Cyan Main Charge Counter has reached the specified life. 
Replace C Main Charge Kit 
 
MCM
 
Magenta Main Charge Counter has reached the specified life. 
Replace M Main Charge Kit 
 
MCY
 
Yellow Main Charge Counter has reached the specified life. 
Replace Y Main Charge Kit 
 
VK 
Black Developer Counter has reached the specified life. 
Replace Black Developer
 
 
VC 
Cyan Developer Counter has reached the specified life. 
Replace Colour Developer Kit 
(CMY) 
 
VM 
Magenta Developer Counter has reached the specified life. 
 
VY 
Yellow Developer Counter has reached the specified life. 
 
FK1 
Fusing Belt Print Counter has reached the specified limit. 
Replace the Fusing Belt Kit
 
FUSER
 
 
FK2 
Pressure Roller Print Counter has reached the specified limit. 
Replace the Pressure Roller Kit
 
 
TK1
 
Primary Transfer Unit Counter has reached the specified limit. 
Replace the Primary Transfer 
Belt & Blade Kits
 
TRANSFE
R
 
 
TK2
 
Secondary Transfer Unit Counter has reached the specified limit. 
Replace the Secondary Transfer 
Roller Kit
 
 
TK3
 
PTC Unit Counter has reached the specified limit. 
Replace the PTC Unit
 
 
TA 
Maintenance [All] Counter has reached specified limit 
 
CA 
Maintenance [Colour] Counter has reached specified limit 
 
AA 
Maintenance [All] & [Colour] Counters have reached the specified limits 
 
Starting Powder: 
 
The following starting powder should be applied to the relevant consumable item during maintenance:- 
 
Starting Powder 
OPC Drum 
Primary Transfer Belt 
MX-2630N 
UKOG-0312FCZZ 
[Stearic Acid] 
CKOG-0345DS51 
[Yellow Toner] 
 
 
MAINTENANCE 
SHARP  
 
Page 16
/75
 
MX-2630N Handy Guide NOV’17 
Sharp Office Solutions Group
 
 
MX-2630N 
PROCESS SECTION – COLOUR: 
(Colour maintenance counter has reached the specified life). 
Every 
150K 
Every 
300K 
 
 
 
 
 
Replace Cyan, Magenta & Yellow OPC Drum: (MX-60GRSA x 3)  
 
 
Replace Cyan, Magenta & Yellow Main Charge Kits:- 
 
 
•  Main Charge Unit & Cleaning Blade (MX-407MK x 3) 
 
Replace C, M, Y Developer (MX-60GVSA). 
 
 
Clean LSU Dust Proof Glass (CMYK) 
 
 
Sim 24-04  
Clear Drum CTRG C, M, Y (Colour) Counters. 
 
 
 
 
Clear Main Charger C, M, Y (Colour) Counters. 
 
 
(MC Cleaner Counter is also cleared automatically) 
 
 
 
 
Clear Drum Blade C, M, Y (Colour) Counters. 
 
 
 
 
Clear Maintenance [Colour] Counter. 
 
 
Sim 24-05  
Clear Developer C, M, Y (Colour) Counters. 
 
Remove ALL toner cartridges, prior to executing Sim 25-02.
 
 
Sim 25-02  
Toner Concentration Adjustment - Select C, M, Y. 
 
 
Note:   
If ALL developer is replaced at the same time, select CMYK. When 
Sim 25-02 is executed, the Developer Counter (Sim 24-05) is also 
cleared automatically. 
 
Sim 44-27  
Clear Half Tone Process Correction. 
 
 
Every 
180K 
Every 
360K 
PROCESS SECTION -MONOCHROME: 
(Total / K maintenance counter has reached the specified life). 
 
 
 
 
 
Replace Black OPC Drum (MX-60GRSA). 
 
 
Replace Black Main Charge Kit:- 
 
 
•  Main Charge Unit & Cleaning Blade (MX-407MK) 
 
Replace Black Developer (MX-60GVBA). 
 
 
Clean LSU Dust Proof Glass (CMYK) 
 
 
Sim 24-04  
Clear Drum CTRG K (Black) Counter. 
 
 
 
 
Clear Main Charger K (Black) Counter. 
 
 
(MC Cleaner Counter is also cleared automatically) 
 
 
 
 
Clear Drum Blade K (Black) Counter. 
 
 
 
 
Clear Maintenance [ALL] Counter. 
 
Sim 24-05  
Clear Developer K (Black) Counter. 
 
Remove ALL toner cartridges, prior to executing Sim 25-02.
 
 
Sim 25-02  
Toner Concentration Auto Adjustment - Select K. 
 
 
Note:   
If ALL developer is replaced at the same time, select CMYK. When 
Sim 25-02 is executed, the Developer Counter (Sim 24-05) is also 
cleared automatically. 
 
 
Page of 75
Display