Sharp MX-2610N / MX-3110N / MX-3610N (serv.man14) Service Manual ▷ View online

MX-3610N  Dehumidifying heater  3 – 9
3)
Hang the SCN-WH harness to the main drive unit.
4)
Connect the SCN-WH harness to the WH PWB.
(3) Scanner heater unit assembly
1)
Secure the marking position on the harness of the scanner
heater to the heater fixing plate with the banding band.
2)
Extend the harness, and secure the other position of it with
banding band.
3)
Tighten the snap band and cut its tip to approx. 5 mm or less.
Slide the banding band head to the square hole (Part that is
enclosed by the mark).
The banding band head and cut tip must not protrude behind
the heater fixing plate.
(4) Table glass removal
1)
Remove the glass holder. Remove the table glass and the
SPF glass.
(5) Scanner heater unit attachment
1)
Attach the clamp to the scanner frame.
When installing, be careful to prevent damage of the wire.
1
2
3
1
4
5
2
3
MX-3610N  Dehumidifying heater  3 – 10
2)
Remove two screws from the scanner bottom.
3)
Connect the harness of the scanner heater. Attach the scanner
heater unit, and fixing the screw (M3 x 4 Round-tipped).
4)
Attach the scanner heater and secure it with the screw (M4 x 6
Bind machine screw). Pass the harness through the clamp.
The convex part of the scanner heater must be inserted into
the hole of the scanner frame.
5)
Tighten the loose scanner heater harness by pulling it in the
arrow direction and secure it with the snap band then cut its tip
to approx. 5 mm or less.
6)
Move the lamp unit by hand and check that it move smoothly in
all movable area.
Check that there is no interference of the harness of the scan-
ner heater in the wire and the 2/3 mirror unit.
(6) Table glass attachment
1)
Attach the SPF glass and the table glass. Attach the glass
holder.
When installing the glass holder, slide it to the left until it clicks,
and fix it with screws.
2)
Install the RSPF harness guide.
2
2
1
1
2
5
2
1
4
3
2
1
3
4
MX-3610N  Dehumidifying heater  3 – 11
(7) External fixture attachment
1)
Attach the rear cabinet.
2)
Attach the rear upper cabinet.
Check to confirm that the wire is not in contact with the har-
ness fixing plate.
If the wire should be in contact with the harness fixing plate
and the upper rear cabinet should be installed under this con-
dition, the wire may be caught between the both parts to be
damaged, causing a short circuit.
3)
Attach the left cabinet upper.
4)
Attach the left cabinet.
5)
Attach the paper exit cover.
1
2
2
2
2
2
1
2
2
2
1
wire
harness fixing plate
wire
harness fixing plate
2
1
1
2
MX-3610N  Dehumidifying heater  3 – 12
D. Desk heater kit installation
(1) Tray 2 heater unit assembly
1)
Attach the desk heater to the heater mounting plate, and fix it
with a screw (M3 x 4).
(2) Tray 3/4 heater unit assembly
1)
Attach the desk heater to the heater mounting plate, and fix it
with a screw (M3 x 4).
2)
Attach the edge wire saddle and the desk heater mounting
plate to the heater radiating plate, and fix them with a screw
(M3 x 4). Pass the desk heater harness through the edge wire
saddle.
(3) Rear cabinet and right rear cabinet removal
1)
Remove the rear cabinet and the right rear cabinet.
(4) Heater harness attachment
1)
Attach the snap band of the heater harness to the frame.
Fix the earth wire to the frame with a screw (M4 x 8).
(5) Heater harness 2 attachment
1)
Remove the mounting plate.