Sharp DX-C200P Service Manual ▷ View online
[5]Replacement and Adjustment
5-56
13. Install it on the new EGB with the mark [A] pointing to the right side of the board after
you replace the EGB.
14. Replace the EEPROM if the EEPROM on the old EGB is defective.
Keep the EEPROM away from any objects that can cause static electricity. Static
electricity can damage EEPROM data.
Make sure that the EEPROM is correctly installed on the EGB.
FCU (only for DX-C200)
1 Rear cover (
p. 5-5)
2. Controller box cover (
p. 5-49)
3. FCU and Speaker bracket (
p. 5-52)
[5]Replacement and Adjustment
5-57
4. FCU [A] (
x 4)
Interlock Switches
1 Operation panel (
p. 5-6)
2. Rear cover (
p. 5-5)
3. Left cover (
p. 5-7)
4. Interlock switch base [A] (
x 4,
x 4)
[5]Replacement and Adjustment
5-58
Removing the spring [B] first makes this procedure easier.
Remove all the connectors after the interlock switch base has been removed.
5. Two interlock switches [C] at the outside of the base and one interlock switch [D] at the
inside of the base (hooks x 2)
Fusing Fan Motor
1 Operation panel (
p. 5-6)
2. Rear cover (
p. 5-5)
3. Left cover (
p. 5-7)
4. Interlock switch base (
p. 5-57)
5. Fusing fan base [A] (
x 2,
x 1)
[5]Replacement and Adjustment
5-59
6. Fusing fan motor [B] (hooks x 2,
x 1)
Install the fusing fan motor with its decal facing the outside of the machine.
Fusing Stripper Pawl Solenoid
1 Open the front cover.
2. Open the top cover.
3. Rear cover (
p. 5-5)
4. Right cover (
p. 5-7)
5. Fusing stripper pawl solenoid assembly [A] (
x 4,
x 1)
Click on the first or last page to see other DX-C200P service manuals if exist.