Sharp DX-C200P Service Manual ▷ View online
[5]Replacement and Adjustment
5-44
8. Stand the machine with the rear side facing the table.
9. Slide the paper feed shaft [A] to the left side ( x 2).
10. Paper feed roller [B] (hook)
Separation Pad
1 Pull out the tray.
2. Push down the bottom plate [A].
3. Separation pad [B] (hooks x 2, spring x 1)
[5]Replacement and Adjustment
5-45
When reinstalling the separation pad, make sure that the Mylar [C] is not placed
under the separation pad. The right side image above shows incorrect installation.
Paper End Sensor
1 Rear cover (
p. 5-5)
2. Right cover (
p. 5-7)
3. High voltage power supply board (
p. 5-66)
4. Paper end sensor assembly [A] (
x 1)
5. Paper end sensor [B] (hooks x 3)
[5]Replacement and Adjustment
5-46
Paper Exit
Paper Exit Roller
1 Operation panel (
p. 5-6)
2. Remove the bushing [A] ( x 1)
3. Pull out the paper exit roller [B] from the right stay, and move its left side towards the
front slightly, and then remove it from the mainframe. ( x 1)
[5]Replacement and Adjustment
5-47
4. Remove the four exit guides [C] and gear [D] (bushing x 1).
Paper Exit Sensor
1 Rear cover (
p. 5-5)
2. Right cover (
p. 5-7)
3. Fusing pawl solenoid assembly [A] (
x 4)
Click on the first or last page to see other DX-C200P service manuals if exist.