Sharp DX-C200P Service Manual ▷ View online
[5]Replacement and Adjustment
5-32
5. Release the holder [D] at the left side of the transfer roller unit (hook).
6. Transfer roller [E]
7. Execute "Reset 2nd Transfer Unit" with the "Engine Maintenance" menu .
Registration Roller
1 Transfer unit (
p. 5-30)
2. Transfer roller unit (
p. 5-30)
3. Tension springs [A] (both sides)
4. Registration idle roller [B] ( x 2, gear x 1, bushing x 2)
5. Registration roller [C] ( x 2, gear x 2, bushing x 2)
[5]Replacement and Adjustment
5-33
Reassembling the registration roller unit
When installing the tension spring, make sure that the tension spring correctly hooks onto
the bushing of the registration idle roller as shown above [A].
Registration Sensor
1 Right Cover (
p.5-7)
2. Registration sensor assembly [A] (
x 1,
x 1)
[5]Replacement and Adjustment
5-34
3. Registration sensor [B] (hooks)
Registration Clutch
1 Rear cover (
p. 5-5)
2. Left cover (
p. 5-7)
3. Transport/Fusing motor (
p. 5-40)
4. Registration clutch [A] ( x 1)
[5]Replacement and Adjustment
5-35
Image Fusing
Make sure that the fusing unit is cool before you touch it. The fusing unit can be
very hot.
Make sure to restore the insulators, shields, etc after you service the fusing unit.
Fusing Unit
Execute "Reset Fuser Unit" with the "Engine Maintenance" menu if you replace the
fusing unit, otherwise a fusing error may occur.
1 Open the front cover.
2. Left cover (
p. 5-7)
3. Disconnect the connectors [A], [B].
Click on the first or last page to see other DX-C200P service manuals if exist.