[5]Replacement and Adjustment 
 
 
 
  5-32 
 
 
 
 
5.  Release the holder [D] at the left side of the transfer roller unit (hook). 
6.  Transfer roller [E] 
7.  Execute "Reset 2nd Transfer Unit" with the "Engine Maintenance" menu .   
Registration Roller 
1  Transfer unit (
  p. 5-30) 
2.  Transfer roller unit (
  p. 5-30) 
 
3.  Tension springs [A] (both sides)   
4.  Registration idle roller [B] (   x 2, gear x 1, bushing x 2) 
5.  Registration roller [C] (   x 2, gear x 2, bushing x 2) 
[5]Replacement and Adjustment 
 
 
 
  5-33 
 
 
 
Reassembling the registration roller unit 
 
When installing the tension spring, make sure that the tension spring correctly hooks onto 
the bushing of the registration idle roller as shown above [A]. 
Registration Sensor 
1  Right Cover (
  p.5-7) 
 
2.  Registration sensor assembly [A] (
  x 1, 
  x 1) 
 
[5]Replacement and Adjustment 
 
 
 
  5-34 
 
 
 
3.  Registration sensor [B] (hooks) 
Registration Clutch 
1  Rear cover (
  p. 5-5) 
2.  Left cover (
  p. 5-7) 
3.  Transport/Fusing motor (
  p. 5-40) 
 
4.  Registration clutch [A] (   x 1) 
[5]Replacement and Adjustment 
 
 
 
  5-35 
 
 
 
Image Fusing 
 
 
Make sure that the fusing unit is cool before you touch it. The fusing unit can be 
very hot. 
 
Make sure to restore the insulators, shields, etc after you service the fusing unit. 
Fusing Unit 
 
 
Execute "Reset Fuser Unit" with the "Engine Maintenance" menu if you replace the 
fusing unit, otherwise a fusing error may occur.
 
1  Open the front cover. 
2.  Left cover (
  p. 5-7) 
 
3.  Disconnect the connectors [A], [B]. 