DOWNLOAD Sharp AR-P350 / AR-P450 (serv.man8) Service Manual ↓ Size: 6.17 MB | Pages: 81 in PDF or view online for FREE

Model
AR-P350 AR-P450 (serv.man8)
Pages
81
Size
6.17 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARP350 and ARP450 Service Manual
File
ar-p350-ar-p450-sm8.pdf
Date

Sharp AR-P350 / AR-P450 (serv.man8) Service Manual ▷ View online

AR-P350 TROUBLE CODES-2
2.Details of trouble codes
U2
12 Adjustment value check sum 
error (Controller EEPROM)
Controller
90 PCU section EEPROM read/
write error
PCU
91 PCU section memory sum 
check error
PCU
U7
00 PC/MODEM communication 
error
Controller
PF
--
RIC copy inhibit command 
reception
Controller
CH
--
Door open (CH ON)
PCU
00 No developer cartridge
PCU
01 No toner cartridge
PCU
--
--
Auditor not ready
Controller
PC
--
Personal counter not installed
Controller
MAIN
SUB
C1
00
Content
MC trouble
Detail
Main charger output abnormality 
(Output open)
Trouble signal is outputted from the high 
voltage transformer.
Cause
The main charger is not installed properly.
The main charger is not assembled properly.
Disconnection of connector of high voltage 
transformer.
High voltage harness disconnection or 
breakage.
Check and 
remedy
Use the diag mode or DIAG to check the 
main charger output.
Check for disconnection of the main charger. 
Replace the high voltage unit. 
E7
02
Content
Laser trouble
Detail
BD signal from LSU is kept OFF, or ON.
Cause
The connector of LSU or the harness in LSU 
is disconnected or broken.
The polygon motor does not rotate normally.
The laser home position sensor in LSU is 
shifted.
The proper voltage is not supplied to the 
power line for laser.
Laser emitting diode trouble
PCU PWB trouble
Controller PWB trouble
Check and 
remedy
Check for disconnection of the LSU 
connector. 
Use DIAG (SIM 61-1) to check LSU 
operation.
Check that the polygon motor rotates 
normally or not.
Check light emission of laser emitting diode.
Replace the LSU unit.
Replace the PCU PWB.
Replace the Controller PWB.
Trouble 
codes
Contents
Remark
Trouble 
detection
E7
03
Content
HDD trouble
Detail
HDD does not operate properly in the 
machine with HDD installed.
Cause
HDD is not installed properly to the Controller 
PWB.
HDD does not operate properly in the 
Controller PWB.
Controller PWB trouble
Check and 
remedy
Check installation of HDD to the Controller 
PWB.
Check connection of the harness of HDD to 
the Controller PWB. 
Use DIAG (SIM 62-2, -3) to check read/write 
of HDD.
Replace HDD.
Replace Controller PWB. 
06
Content
Decode error trouble
Detail
A decode error occurs during making of an 
image.
Cause
Data error during input from PCI to PM.
PM trouble
Data error during image compression/
transfer.
Controller PWB abnormality
Check and 
remedy
Check insertion of the PWB. (PCI bus)
If the error occurred in a FAX job, check 
installation of the FAX PWB. 
For the other cases, check the Controller 
PWB. 
Replace the Controller PWB. 
50
Content
LSU connection trouble
Detail
An LSU which does not conform to the 
machine is installed. 
Cause
PCU PWB trouble
LSU trouble
Check and 
remedy
Check LSU PWB. Check PCU PWB.
Check connection of the connector and the 
harness between PCU and LSU.
F1
00
Content
Finisher communication trouble
Detail
Communication cable test error after turning 
on the power or exiting from DIAG.
Communication error with the finisher
Cause
Improper connection or disconnection of 
connectors and harness between the 
machine and the finisher.
Finisher control PWB trouble
Control PWB (PCU) trouble
Malfunction by noises
Check and 
remedy
Canceled by turning OFF/ON the power.
Check connectors and harness in the 
communication line. 
Replace the finisher control PWB or PCU 
PWB.
08
Content
Finisher staple shift motor trouble
Detail
Staple motor drive trouble
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check operations of 
the staple motor.  
MAIN
SUB
AR-P350 TROUBLE CODES-3
F1
80
Content
Finisher power abnormality
Detail
The 24V power is not supplied to the finisher 
PWB. 
Cause
Improper connection or disconnection of 
connector and harness
Finisher control PWB trouble
Power unit trouble
Check and 
remedy
Use DIAG (SIM3-2) to check the sensor.
87
Content
Finisher staple rotation motor trouble
Detail
Front staple rotation motor trouble
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation.
F1
00
Content
Mail box communication trouble
Detail
Communication cable test error after turning 
on the power or exiting from DIAG.
Communication error with the mail box.
Cause
Improper connection or disconnection of 
connector and harness between the machine 
and the mail box. 
Mail box control PWB trouble
Control PWB (PCU) trouble
Malfunction by noises
Check and 
remedy
Canceled by turning OFF/ON the power.
Check harness and connector in the 
communication line.
Replace the mail box PWB or PCU PWB.
02
Content
Mail box transport motor abnormality
Detail
Transport motor trouble
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Mail box control PWB trouble
Check and 
remedy
Use DIAG (SIM3-21) to check the transport 
motor operation.
12
Content
Mail box gate trouble
Detail
Gate operation abnormality
Cause
Gate lock
Mail box control PWB trouble
Check and 
remedy
Use DIAG (SIM3-21) to check the transport 
gate operation. 
80
Content
Finisher power abnormality
Detail
The 24V power is not supplied to the finisher 
PWB.
Cause
Improper connection or disconnection of 
connector and harness
Finisher control PWB trouble
Power unit trouble
Check and 
remedy
Use DIAG (SIM3-20) to check the sensor 
operation.
MAIN
SUB
F1
03
Content
Console finisher paddle motor trouble
Detail
Paddle motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
06
Content
Console finisher slide motor trouble
Detail
Slide motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
10
Content
Console finisher stapler motor trouble
Detail
Stapler motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
11
Content
Console finisher bundle exit motor trouble
Detail
Bundle exit motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
15
Content
Console finisher lift motor trouble
Detail
Lift motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
19
Content
Console finisher front alignment motor 
trouble
Detail
Front alignment motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
20
Content
Console finisher rear alignment motor trouble
Detail
Rear alignment motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
MAIN
SUB
AR-P350 TROUBLE CODES-4
F1
30
Content
Console finisher communication trouble
Detail
Communication cable test error after turning 
on the power or exiting from DIAG.
Communication error with the console 
finisher
Cause
Improper connection or disconnection of 
connector and harness between the machine 
and the console finisher.
Console finisher control PWB trouble
Control PWB (PCU) trouble
Malfunction by noises
Check and 
remedy
Canceled by turning OFF/ON the power.
Check connectors and harness in the 
communication line. 
Replace the console finisher control PWB or 
PCU PWB. 
31
Content
Console finisher fold sensor trouble
Detail
Sensor input value abnormality
Cause
Sensor breakage
harness breakage
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-2) to check the sensor 
operation.
32
Content
Communication trouble between the console 
finisher and the punch unit. 
Detail
Communication err between the console 
finisher and the punch unit. 
Cause
Improper connection or disconnection of 
connector and harness between the console 
finisher and the punch unit. 
Console finisher control PWB trouble
Control PWB (PCU) trouble
Malfunction by noise
Check and 
remedy
Canceled by turning OFF/ON the power.
Check connectors and harness in the 
communication line. 
Replace the console finisher control PWB. 
33
Content
Console finisher punch side registration 
motor trouble
Detail
Punch side registration motor operation 
abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
34
Content
Console finisher punch motor trouble
Detail
Punch motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
35
Content
Console finisher punch side registration 
sensor trouble
Detail
Sensor input value abnormality
Cause
Sensor breakage
Harness disconnection
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-2) to check the sensor 
operation.
MAIN
SUB
F1
36
Content
Console finisher punch timing sensor trouble
Detail
Sensor input value abnormality
Cause
Sensor breakage
Harness disconnection
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-2) to check the sensor 
operation.
37
Content
Console finisher backup RAM trouble
Detail
Backup RAM contents are disturbed.
Cause
Console finisher control PWB trouble
Malfunction by noise
Check and 
remedy
Replace the console finisher control PWB.
38
Content
Console finisher punch backup RAM trouble
Detail
Punch unit backup RAM contents are 
disturbed.
Cause
Punch control PWB trouble
Malfunction by noise
Check and 
remedy
Replace the punch control PWB.
81
Content
Console finisher transport motor abnormality
Detail
Transport motor trouble
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and 
remedy
Use DIAG (SIM3-3) to check the motor 
operation. 
F2
00
Content
Toner control sensor abnormality
Detail
Toner control sensor output open
Cause
Connector harness trouble
Connector disconnection
Check and 
remedy
Check connection of the toner control sensor.
Check connection of connector and harness 
to the main PWB. 
Check for disconnection of harness.
02
Content
Toner supply abnormality
Detail
Toner control sensor output value becomes 
under-toner too earlier.
Cause
Connector harness trouble
Toner control sensor trouble
Check and 
remedy
Check connection of the connector in the 
toner motor section.
Check connection of connector and harness 
to the main PWB. 
Check for disconnection of harness.
Toner control sensor output check DIAG 
(SIM25-1)
04
Content
Improper cartridge (life cycle error, etc.)
Detail
An improper process cartridge is inserted.
Cause
IC chip trouble
Improper cartridge
Check and 
remedy
Insert a proper cartridge.
05
Content
CRUM error
Detail
Communication with IC chip cannot be 
made.
Cause
IC chip trouble
Improper cartridge
Check and 
remedy
Insert a proper cartridge.
MAIN
SUB
AR-P350 TROUBLE CODES-5
F2
39
Content
Process thermistor trouble
Detail
Process thermistor open
Cause
Process thermistor trouble
Process thermistor harness disconnection
PCU PWB trouble
Check and 
remedy
Check connection of harness and connector 
of the process thermistor.
Check PCU PWB.
F3
12
Content
Machine no. 1 tray lift-up trouble
Detail
PED does not turn ON in the specified time.
LUD does not turn ON in the specified time.
Cause
PED/LUD trouble
No. 1 tray lift-up trouble
Check connection of harness between the 
PCVU PWB, lift-up unit, and paper feed unit.
Check and 
remedy
Check PED, LUD, and their harness and 
connectors.
Check the lift-up unit. 
22
Content
Machine No. 2 tray lift-up trouble
Detail
MCPED does not turn ON in the specified 
time.
MCLUD does not turn ON in the specified 
time.
Cause
MCPED/MCLUD trouble
No. 2 tray lift-up motor trouble
Harness disconnection f the PCU PWB, the 
lift-up unit, and the paper feed unit.
Check and 
remedy
Check MCPED, PCLUD, and their harness 
and connectors. 
Check the lift-up unit. 
H2
00···
HL1
(RT
H1)
01···
HL2
(RT
H2)
Content
thermistor open
Fusing unit not installed
Detail
Thermistor is open. 
(An input voltage of 2.92V or above is 
detected.)
Fusing unit not installed
Cause
Thermistor trouble
Control PWB trouble
Fusing section connector disconnection
AC power trouble
Fusing unit not installed
Check and 
remedy
Check harnesses and connectors from the 
thermistor to the control PWB.
Use DIAG (SIM14) to clear the self diag 
display.
H3
00···
1HL1
(RT
H1)
01···
HL2
(RT
H2)
Content
Fusing section high temperature trouble
Detail
The fusing temperature exceeds 242°C. 
(An input voltage of 0.27V or above is 
detected.)
Cause
thermistor trouble
Control PWB trouble
Fusing section connector disconnection
AC power trouble
Check and 
remedy
Use DIAG (SIM5-2) to check the heater lamp
Blinking operation.
If the heater lamp blinks normally:
Check the thermistor and its harness.
Check the thermistor input circuit in the 
control PWB.
If the heater lamp keep lighting:
Check the AC PWB and the lamp control 
circuit in the control PWB.
Use DIAG (SIM14) to cancel the trouble
MAIN
SUB
H4
00···
1HL1
(RT
H1)
01···
HL2
(RT
H2)
Content
Fusing section low temperature trouble
Detail
•The set temperature is not reached within
the specified time (normally 3 min) when
warming up or resetting from pre-heating.
•Under the ready state. 
(An input voltage of 1.21V or below is
detected 5 times continuously.)
Cause
thermistor trouble
Heater lamp trouble
Control PWB trouble
Thermostat trouble
AC power trouble
Interlock switch trouble
Check and 
remedy
Use DIAG (SIM5-2) to check the heater lamp
Blinking operation.
If the heater lamp blinks normally:
Check the thermistor and its harness.
Check the thermistor input circuit in the 
control PWB.
If the heater lamp does not light:
Check for heater lamp disconnection and 
thermostat disconnection.
Check the interlock switch.
Check the AC PWB and the lamp control 
circuit in the control PWB.  
Use DIAG (SIM14) to cancel the trouble.
H5
01
Content
5-time continuous POD1 not-reaching jam 
detection
Detail
5-time continuous POD1 not-reaching jam 
detection
Cause
A fusing section jam is not properly removed. 
(Jam paper remains.)
POD1 sensor trouble, or harness 
disconnection
Improper installation of fusing unit
Check and 
remedy
Check jam paper in the fusing section. 
(winding, etc.)
Check POD1 sensor harness, and check 
installation the fusing unit.
Use DIAG (SIM14) to cancel the trouble.
L4
01
Content
Main motor lock detection
Detail
The motor lock signal is detected for 1.5sec 
during rotation of the main motor.
Cause
main motor trouble
Check connection of harness between the 
PCU PWB and the main motor. 
Control circuit trouble
Check and 
remedy
Use DIAG (SIM25-1) to check the main 
motor operation.
Check harness and connector between the 
PCU PWB and the main motor.
02
Content
Drum motor lock detection
Detail
The motor lock signal is detected for 1.5sec 
during rotation of the drum motor.
Cause
Drum motor trouble
Improper connection of harness between the 
PCU PWB and the drum motor.
Control circuit trouble
Check and 
remedy
Use DIAG (SIM25-1) to check the drum 
motor operation.
Check harness and connector between the 
PCU PWB and the drum motor.
MAIN
SUB
Page of 81
Display