DOWNLOAD Sharp AR-M700 (serv.man27) Service Manual ↓ Size: 948.19 KB | Pages: 97 in PDF or view online for FREE

Model
AR-M700 (serv.man27)
Pages
97
Size
948.19 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Simulation
File
ar-m700-sm27.pdf
Date

Sharp AR-M700 (serv.man27) Service Manual ▷ View online

: Feb. 9 2004
1
AR-M550/M620/M700  SIMULATION  8 - 41
Operation/Procedure
1) Press [START] key.
The developing motor and the OPC drum motor rotate, and the
toner concentration detection level and the humidity sensor detec-
tion level are displayed.
Operation/Procedure
1) Press [START] key.
The developing motor rotates for 3 min and the toner concentration
sensor makes sampling of toner concentration to display the
detection level.
After the developing motor stops, the average value of toner con-
centration sampling is set as the reference toner concentration
level.
NOTE: When the above operation is interrupted on the way, the refer-
ence toner concentration level is not set. Also when error code
of EE-EL or EE-EU is displayed, the reference toner concentra-
tion level is not set normally.
 (Default: 114)
Operation/Procedure
1) Select the number corresponding to the paper feed unit for setting
the paper size with 10-key. 
2) Press [START] key.
3) Select the number corresponding to the paper size. 
4) Press [START] key.
Operation/Procedure
1) Select the number corresponding to the auditor mode with 10-key. 
2) Press [START] key.
(Default: 1)
Press [START] key.
Press [CUSTOM SETTINGS] key, and the 
operation is stopped immediately or after 3 min.
25-2
Purpose
Setting
Function
(Purpose)
Used to make the initial setting of toner concentration 
when replacing developer.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
2) The humidity near the developing tank at the developing adjust-
ment is registered.
Press [START] key.
Press [CUSTOM SETTINGS] key, and the 
operation is stopped immediately or after 3 min.
SIMULATION 25-1
TONER SENSOR OUTPUT MONITOR. PRESS START.
HUMIDITY AREA :   
70.0
 - 
72.5
DEVE REFERENCE :  
128
SIMULATION 25-1
DV MONITOR. EXECUTING···.
HUMIDITY AREA :   
70.0
 - 
72.5
DEVE REFERENCE :  
128
1
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. PRESS START.
HUMIDITY AREA :   
70.0
 - 
72.5
DEVE REFERENCE :  
114
1
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. EXECUTING···.
HUMIDITY AREA :   
70.0
 - 
72.5
DEVE REFERENCE :  
114
26
26-2
Purpose
Setting
Function
(Purpose)
Used to set the paper size of the large capacity tray 
(LCC) and the paper feed tray 2. (When the paper size 
is changed, this simulation must be executed to 
change the paper size in software.)
Section
Paper feed
Item
Setting
1
TRAY 2
TRAY 2 size (0 = 8.5 x 11, 1 = A4, 2 = B5)
2
LCC
Side LCC size  (0 = 8.5 x 11, 1 = A4, 2 = B5)
Press [START] key.
Press [CUSTOM SETTINGS] key.
26-3
Purpose
Setting
Function
(Purpose)
Used to set the specifications of the auditor. Setting 
must be made according to the auditor use conditions.
Section
Auditor
Item
Specifications
1
P10
Built-in auditor mode
2
VENDOR
Coin vendor mode
3
OTHERS
Other
SIMULATION 26-2
1
SIZE SETUP. SELECT NUMBER, AND PRESS START.
1. TRAY2           
1
2. LCC             
1
SIMULATION 26-2
LCC SIZE SETUP. SELECT 0-2, AND PRESS START.
0. 8.5x11
1. A4
2. B5
1
SIMULATION 26-3
AUDITOR SETUP. SELECT 1-3, AND PRESS START.
1. P10
2. VENDOR
3. OTHERS
1
AR-M550/M620/M700  SIMULATION  8 - 42
Operation/Procedure
1) Select the number corresponding to the counter to be set with 10-
key. 
2) Press [START] key. 
3) Select the count mode with 10-key.
4) Press [START] key.
Set the count-up (1 or 2) for A3/WLT paper.
(Select the target counter.)
(Count-up)
Operation/Procedure
1) Select the number corresponding to the destination with 10-key. 
2) Press [START] key.
After completion of setting, the machine is automatically reset.
Since this simulation cannot change the Fax destination, use SIM 66-2
to change the FAX destination.
Operation/Procedure
1) Select START/END of the network scanner trial mode with 10-key. 
2) Press [START] key.
Max. 500 menus can be scanned.
Operation/Procedure
1) Select YES/NO of the toner save mode with 10-key. 
2) Press [START] key.
Operation/Procedure
1) Select the number corresponding to the operation mode with 10-
key.
2) Press [START] key.
(Default: 1 for Europe, 0 for the others)
26-5
Purpose
Setting
Function
(Purpose)
Used to set the count mode of the total counter and the 
maintenance counter.
Section
Item
Specifications
Counter
1
TOTAL COUNTER
Total counter
2
MAINTENANCE (DRUM) 
COUNTER
Maintenance counter/ OPC 
drum counter
3
DV COUNTER
Developer counter
1
1 COUNT UP
1 count-up
2
2 COUNT UP
2 count-up
Default
Press [START] key.
Press [CUSTOM SETTINGS] key.
26-6
Purpose
Setting
Function
(Purpose)
Used to set the specifications (paper, fixed 
magnification ratio, etc.) of the destination.
Section
Item
Specifications
Destination
1
USA
United States of America
2
CANADA
Canada
3
INCH
Inch series EX
4
JAPAN
Japan
5
AB_B
AB series B5
6
EUROPE
Europe
7
UK
UK
8
AUSTRALIA
Australia
9
AB_A
AB series A5
10
CHINA
China
SIMULATION 26-5
1
A3(LEDGER) COUNT UP MODE SETTING. SELECT 1-3, AND PRESS
START.
1. TOTAL COUNTER 
1
2. MAINTENANCE(DRUM) COUNTER 
1
3. DV COUNTER 
1
SIMULATION 26-5
A3(LEDGER) COUNT UP MODE SETTING. SELECT 1-2, AND PRESS
START.
1. TOTAL COUNTER
(1: 1COUNT UP,  2: 2COUNT UP)
1
26-10
Purpose
Setting
Function
(Purpose)
Used to set the network scanner trial mode.
Section
Item
Operation
0
END
Trial mode cancel
Default
1
START
Trial mode start
26-18
Purpose
Setting
Function
(Purpose)
Used to set YES/NO of toner save operation. (This 
function is valid only in Japan and UK versions. 
(Depends on the destination setting of SIM26-6.) For 
the other destinations, the same setting can be made 
by the user program P22.)
Section
Item
Specifications
Operation mode
0
YES
Toner save mode is set.
1
NO
Toner save mode is not set.
Default
26-30
Purpose
Setting
Function
(Purpose)
Used to set the operation mode conforming to the CE 
mark (Europe safety standards). (Conforming to soft 
start when driving the fusing heater lamp.)
Section
Item
Specifications
Operation mode (Common)
0
NO
CE mark control NO (Normal operation)
1
YES
CE mark control YES (Heater lamp soft start operation)
SIMULATION 26-6
DESTINATION SETUP. SELECT 1-10, AND PRESS START.
1.USA 2.CANADA 3.INCH
4.JAPAN 5.AB_B
6.EUROPE 7.UK 8.AUSTRALIA
9.AB_A   10.CHINA
1
SIMULATION 26-10
NETWORK SCANNER TRIAL SETTING. SELECT 0-1, AND PRESS
START.
0.END
1.START
1
SIMULATION 26-18
TONER SAVE MODE SETTING. SELECT 0-1, AND PRESS START.
0. YES
1. NO
1
: Feb. 9 2004
1
AR-M550/M620/M700  SIMULATION  8 - 43
Operation/Procedure
1) Select the number corresponding to the operation mode with 10-
key.
2) Press [START] key.
(Default: 0)
Operation/Procedure
1) Select the number corresponding to the operation mode with 10-
key.
2) Press [START] key.
(Default: 0)
Operation/Procedure
2) Press [START] key.
(Default: 1 for Europe and UK, 0 for the others)
Operation/Procedure
1) Select ENABLE/DISABLE of the B/W reverse mode with 10-key.
2) Press [START] key.
Operation/Procedure
1) Select YES/NO of the non-print paper count-up with 10-key.
2) Press [START] key. 
Non-print paper means an insert paper (without copying) in the OHP
insertion mode, a cover (without copying) in the cover insertion mode,
back surface, and white paper in the duplex exit mode (CA, etc.).
(Default: 0 for Japan and Australia, 1 for the other)
The target counters are as follows:
• Copies counter
• Printer counter
• Department management counter
26-35
Purpose
Setting
Function
(Purpose)
Used to set whether the same continuous troubles are 
displayed as one trouble or the series of troubles with 
SIM 22-4 when the same troubles occur continuously.
Section
Item
Specifications
0
ONCE
When two or more troubles of a same kind occur 
continuously, the troubles are displayed as one 
trouble in the trouble history of SIM22-4. 
1
ANY
When two or more troubles of a same kind occur 
continuously, the troubles are displayed straightly as 
two or more troubles in the trouble history of SIM22-
4. 
26-38
Purpose
Setting
Function
(Purpose)
Used to set CONTINUE/STOP of printing when 
maintenance timing is over and the count value 
reaches 110% of replacement timing (life). 
Section
Other
Item
Specifications
0
PRINT CONTINUE
Print continue
1
PRINT STOP
Print stop
SIMULATION 26-30
CE MARK CONTROL SETTING. SELECT 0-1, AND PRESS START.
0. NO
1. YES
1
1
SIMULATION 26-35
TROUBLE MEMORY MODE SETTING. SELECT 0-1, AND PRESS
START.
0. ONCE
1. ANY
1
1
SIMULATION 26-38
LIFE OVER SETTING. SELECT 0-1, AND PRESS START.
0. PRINT CONTINUE
1. PRINT STOP
1
26-41
Purpose
Setting
Function
(Purpose)
Used to set YES/NO of the automatic magnification 
ratio selection (AMS) in the pamphlet mode.
Section
Item
Specifications
Operation mode (Common)
1) Enter the number corresponding to whether AMS operation is
automatically performed or nor in the center binding mode with the
10-key. 
0
NO
AMS/APS selection allowed
1
YES
AMS is forcibly operated. 
26-50
Purpose
Setting
Function
(Purpose)
Black-White reverse YES/NO setting
Section
Item
Specifications
Operation
0
DISABLE
B/W reverse mode DISABLE
1
ENABLE
B/W reverse mode ENABLE
Default
26-52
Purpose
Setting
Function
(Purpose)
Used to set whether non-print paper (insertion paper, 
cover paper) (blank image print paper) is counted up or 
not.
Section
Paper transport (Discharge/Switchback/Transport)
Item
Specifications
Operation mode
0
NO (NO COUNT UP)
No count up
1
YES (COUNT UP)
Count up
• Total counter
• Effective paper counter
1
1
SIMULATION 26-41
PAMPHLET MODE AMS SETTING. SELECT 0-1, AND PRESS 
START.
0. NO
1. YES
1
SIMULATION 26-50
B/W REVERSE MODE SETTING. SELECT 0-1, AND PRESS 
START.
0. DISABLE
1. ENABLE
1
1
AR-M550/M620/M700  SIMULATION  8 - 44
Operation/Procedure
1) Select ENABLE/DISABLE of the CA key cancel function of print
stop with 10-key.
2) Press [START] key.
(Default: 1)
Operation/Procedure
1) Select the number corresponding to the operation mode with 10-
key.
2) Press [START] key.
(Default: 0)
Operation/Procedure
1) Enter the tag number with 10-key.
2) Press [START] key.
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
26-68
Purpose
Setting
Function
(Purpose)
Used to set ENABLE/DISABLE of the CA key cancel 
function of print stop.
Section
Item
Specifications
Operation
0
DISABLE
Disable
1
ENABLE (PRINT STOP)
Enable
27
27-1
Purpose
Setting
Function
(Purpose)
Used to set the specifications for operations in case of 
communication trouble between the host computer and 
MODEM (machine side). (When communication 
trouble occurs between the host computer MODEM 
and the machine, the self diag display (U7-00) is 
printed and setting for inhibition of print or not is made.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Specifications
Operation mode
0
YES
Though a communication trouble occurs between the 
host computer and the MODEM (machine side), there is 
no effect on the machine operations.
1
NO
When a communication trouble occurs between the host 
computer and the MODEM (machine side), the self diag 
display (U7-00) is displayed and printing is inhibited.
SIMULATION 26-52
BLANK PAPER COUNT UP SETTING. SELECT 0-1, AND PRESS 
START.
0. NO  (NO COUNT UP)
1. YES (COUNT UP)
1
SIMULATION 26-68
CA KEY CANCEL MODE SETTING. SELECT 0-1, AND PRESS 
START.
0. DISABLE
1. ENABLE (PRINT STOP)
0
SIMULATION 27-1
DISABLING OF U7-00 TROUBLE. SELECT 0-1, AND PRESS START.
0. YES
1. NO
1
27-5
Purpose
Setting
Function
(Purpose)
Used to enter the machine tag No. (This function 
allows to check the tag No. of the machine with the 
host computer.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Specifications
Operation mode
30
30-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of sensors and detectors 
in other than the paper feed section and the operations 
of the related circuits.
Section
Item
Operation
PFD2
ADU paper feed detection 2
PPD
Resist roller front paper detection 
PSD
Drum rear paper detection 
POD1
After-fusing transport detection 1
POD2
After-fusing transport detection 2
POD3
Paper full detection
DSW_R
Manual feed door open detection
DSW_L
Cabinet open detection
DSW_F
Front cabinet open detection 
DSW_DSK
Desk door open detection 
TFSD
Toner remaining quantity detection (Motor rotation 
number count)
THPS2
Transfer belt separation home sensor 2
LPPD
LCC paper transport detection
T1PPD
Tandem tray 1 paper transport sensor
SIMULATION 27-5
TAG # SETTING. INPUT VALUE, AND PRESS START.
PRESENT:  00010000
NEW:      
00009999
SIMULATION 30-1
SENSOR CHECK..
PFD2        
PPD
       PSD       POD1      POD2
POD3        DSW_R     DSW_L     DSW_F
DSW_DSK     TFSD      THPS2     LPPD      T1PPD
Page of 97