1
AR-M550/M620/M700  SIMULATION  8 - 25
Operation/Procedure
1) Select the number corresponding to the target of operation check
with 10-key.
2) Press [START] key.
The load selected in procedure 1 turns ON for 10sec.
Press [CUSTOM SETTINGS] key to stop the operation.
The copy lamp or CIS is turned on for 10sec and turned off.
NOTE: CIS: only when the DSPF is installed.
Operation/Procedure
1) Select the number corresponding to the target of operation check
with 10-key.
2) Press [START] key. 
The load selected in procedure 1 turns ON for 30sec.
Press [CUSTOM SETTINGS] key to stop the operation.
Operation/Procedure
1) Select the number corresponding to the target of operation check
with 10-key.
2) Press [START] key.
The load selected in procedure 1 operates.
Press [CUSTOM SETTINGS] key to stop the operation.
5-3
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the scanner lamp and 
the control circuit.
Section
Optical (Image scanning)
Item
Operation
Press [START] key, and the operation is 
started.
Press [CUSTOM SETTINGS] key, and 
the operation is stopped after 10sec.
5-4
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the discharge lamp and 
the related circuit.
Section
Process
Item
Operation
Press [START] key, and the operation 
is started.
Press [CUSTOM SETTINGS] key, and the 
operation is stopped after 30sec.
SIMULATION 5-3
COPY LAMP TEST. SELECT 1-2, AND PRESS START.
1.COPY LAMP
2.CIS
1
SIMULATION 5-3
COPY LAMP TEST. EXECUTING···.
1.COPY LAMP
2.CIS
1
SIMULATION 5-4
DISCHARGE LAMP CHECK. SELECT 1, AND PRESS START.
1.DL
1
SIMULATION 5-4
DISCHARGE LAMP CHECK. SELECT 1, AND PRESS START.
1.DL
1
6
6-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the paper transport 
system loads and the control circuit.
Section
Paper transport (Discharge/Switchback/Transport)
Item
Operation
1
MSWPR
MSW reset signal
2
HLPR
Heater power relay signal
3
DCPR
DC power relay signal
4
MM
Main motor
5
DM
Drum motor
6
DVM
Developing motor
7
TURM
Transfer separation motor
8
TRM
PS front motor
9
POM1
Paper exit motor 1
10
POM2_FW
Paper exit motor 2 forward rotation
11
POM2_RV
Paper exit motor 2 reverse rotation
12
VPM
Paper transport motor
13
RRC
Resist roller clutch signal
14
PSBC
Brake clutch signal 
15
PSPS
Separation pawl
16
T1PFC
Tray 1 paper feed clutch
17
T2PFC
Tray 2 paper feed clutch 
18
HPFC
Horizontal transport clutch 
19
T1PUS
Tray 1 pickup solenoid
20
T2PUS
Tray 2 pickup solenoid
21
HPLS
Relay path clock solenoid
22
T1LUM
Tray 1 lift-up motor 
23
T2LUM
Tray 2 lift-up motor
24
DSKPFC1
Desk paper transport clutch upstream side
25
DSKPFC2
Desk paper transport clutch downstream side
26
M1PFC
Tray 3 paper feed clutch 
27
M2PFC
Tray 4 paper feed clutch
28
M1PUS
Tray 3 pickup solenoid
29
M2PUS
Tray 4 pickup solenoid
30
M1LUM
Tray 3 lift-up motor
31
M2LUM
Tray 4 lift-up motor
32
TRC_LCC
Desk clutch sync signal 
33
FUM
Fusing motor
34
MPFPUS
Manual pickup solenoid
35
MPFC
Manual paper feed clutch signal
36
MPFGS
Manual gate solenoid
: Feb. 9 2004
1
AR-M550/M620/M700  SIMULATION  8 - 26
Operation/Procedure
1) Select the number corresponding to the target of operation check
with 10-key.
2) Press [START] key.
The load selected in procedure 1 operates.
Press [CUSTOM SETTINGS] key to stop the operation.
*
All fans: All the fans controlled by the engine.
Operation/Procedure
1) Select the number corresponding to the target of operation check
with 10-key.
2) Press [START] key.
The transfer belt performs contact/separation with the OPC drum.
Press [CUSTOM SETTINGS] key to stop the operation.
NOTE: Before disassembling the transfer unit, use this simulation to
separate the transfer unit from the OPC drum.
Press [START] key, and the operation 
is started.
Press [CUSTOM SETTINGS] key, and the 
operation is stopped immediately or after 
repeating the operation several times.
6-2
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of each fan motor and its 
control circuit.
Section
Other
Item
Operation
1
VFM-EX
Exhaust fan motor (VFM-EX1, 2, 3, VFM-BKL, 
VFM-BKU)
2
CFM-UP 
Heat exhaust fan motor (Paper exit upper) 
(CFM-U1, 2, 3, VFM-BKR)
3
CFM-R 
Cooling fan motor (Right side) (CFM-R1, 2, 3)
4
CFM-DC
Cooling fan motor (Power source) (CFM-DC1, 
2)
5
CFM-DV
Cooling fan motor (Developing) (CFM-DV)
6
CFM-ICU /HDD
Cooling fan motor (Controller/HDD) (CFM-
ICU/HDD)
7
ALL
All fans control*
8
CFM-AD
Cooling fan motor (paper exit center) (CFM-
U4)
(Exhaust fan motor, heat exhaust fan motor (paper exit upper),
cooling fan motor (right side) cooling fan motor (power source),
cooling fan motor (developing), cooling fan motor (paper exit cen-
ter))
SIMULATION 6-1
FEED OUTPUT CHECK. SELECT 1- 33, AND PRESS START.
1.MSWPR  2.HLPR  3.DCPR  4.MM   5.DM
6.DVM    7.TURM  8.TRM   9.POM1
10.POM2_FW   11.POM2_RV   12.VPM
13.RRC    14.PSBC   15.PSPS   16.T1PFC
17.T2PFC  18.HPFC   19.T1PUS  20.T2PUS
21.HPLS   22.T1LUM  23.T2LUM  24.DSKPFC1
25.DSKPFC2  26.M1PFC  27.M2PFC  28.M1PUS
29.M2PUS    30.M1LUM  31.M2LUM  32.TRC_LCC
33.FUM      34.MPFPUS 35.MPFC   36.MPFGS
    2
SIMULATION 6-1
FEED OUTPUT CHECK. EXECUTING···.
1.MSWPR  2.HLPR  3.DCPR  4.MM   5.DM
6.DVM    7.TURM  8.TRM   9.POM1
10.POM2_FW  11.POM2_RV  12.VPM
13.RRC    14.PSBC   15.PSPS   16.T1PFC
17.T2PFC  18.HFC    19.T1PUS  20.T2PUS
21.HPLS   22.T1LUM  23.T2LUM  24.DSKPFC1
25.DSKPFC2  26.M1PFC  27.M2PFC  28.M1PUS
29.M2PUS    30.M1LUM  31.M2LUM  32.TRC_LCC
33.FUM      34.MPFPUS 35.MPFC   36.MPFGS
    2
1
1
1
1
1
1
1
1
Press [START] key, and the operation 
is started.
Press [CUSTOM SETTINGS] key, and the 
operation is stopped.
6-3
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of the transfer unit and 
the related circuit. 
Section
Process (Transfer)
Item
1
TURM (RELEASE)
Transfer unit separation state
2
TURM (JOINT)
Transfer unit contact state
Press [START] key, and the operation is 
started.
Press [CUSTOM SETTINGS] key, and the 
operation is stopped immediately or after 
repeating the operation several times.
After completion 
Press [CUSTOM SETTINGS] key to stop the 
operation.
SIMULATION 6-2
FAN MOTOR CHECK. SELECT 1-8, CAND PRESS START.
1. VFM-EX   2. CFM-UP 
3. CFM-R    4. CFM-DC
5. CFM-DV   6. CFM-ICU /HDD
7. ALL      8. CFM-AD 
    2
SIMULATION 6-2
FAN MOTOR CHECK..
2. CFM-UP 
  2
SIMULATION 6-3
TURM CHECK. SELECT 1-2 CAND PRESS START.
1. TURM(RELEASE)
2. TURM(JOINT)
    2
SIMULATION 6-3
TURM CHECK. EXECUTING...
1. TURM(RELEASE)
  2
SIMULATION 6-3
TURM CHECK.
COMPLETE....
1. TURM(RELEASE
  2
: Feb. 9 2004
1
AR-M550/M620/M700  SIMULATION  8 - 27
Operation/Procedure
1) Select the number corresponding to the operating condition of
aging with 10-key.
The combined mode of 0 - 6 mode and 10, 20, or 30 mode can be
set.
In that case, the number corresponding to one of 0 - 6 mode and
the number corresponding to one of 10, 10, and 30 mode are
added and the sum number is entered.
2) Press [START] key.
The condition selected in procedure 1) is set.
The setting of this simulation is kept valid until the power is turned off.
Operation/Procedure
1) Enter the intermittent aging cycle (unit: sec) with 10-key.
2) Press [START] key.
The time entered in procedure 1) is set.
Set range of interval time: 1 - 999 (sec)
Set the intermittent aging mode cycle of 7-1 with 10-key. (Unit: sec)
Operation/Procedure
1) Select the number corresponding to the warm-up time display
YES/NO.
2) Press [START] key, and the number selected in procedure 1) is
set.
The setting of this simulation is kept valid until the power is turned
off.
The warm-up time is displayed in the unit of second.
Operation/Procedure
1) Enter the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the set
value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The developing bias output voltage adjustment and output check can
be made in each print mode.)
7
7-1
Purpose
Setting
Function
(Purpose)
Used to set the operating conditions of aging.
Section
Item
Operation
0
NO MISS FEED DETECTION
No jam detection
1
AGING
Aging mode
2
AGING/NO MISS FEED 
DETECTION.
No jam detection, aging 
mode
3
AGING/NO MISS FEED 
DETECTION/NO WARM UP/
NO TEMPERATURE 
CONTROL.
No jam detection/ no warm-
up/ no fusing temperature 
control, aging mode
4
NO WARM UP.
No warm-up 
5
AGING/INTERVAL.
Intermittent aging mode
6
AGING/INTERVAL/NO MISS 
FEED DETECTION.
No jam detection 
intermittent aging mode
+10
NO PROCESS UNIT CHECK.
Above +10: No process unit 
(including the developing 
unit) detection
+20
NO SHADING.
Above +20: No shading
+30
NO PROCESS UNIT CHECK/
NO SHADING.
Above +30: No process unit 
detection /no shading
Press [START] key to start registration and operation. 
The operation mode is kept until the power is turned off or setting is made again. 
7-6
Purpose
Setting
Function
(Purpose)
Used to set the intermittent aging cycle.
Section
Item
Operation
SIMULATION 7-1
AGING TEST SETTING. SELECT 0-36, AND PRESS START.
0.NO MISS FEED DETECTION
1.AGING
2.AGING/NO MISS FEED DETECTION.
3.AGING/NO MISS FEED DETECTION/
  NO WARM UP/NO TEMPERATURE CONTROL.
4.NO WARM UP.
5.AGING/INTERVAL.
6.AGING/INTERVAL/NO MISS FEED DETECTION.
+10:NO PROCESS UNIT CHECK.
+20:NO SHADING.
+30:NO PROCESS UNIT CHECK/NO SHADING.
    2
7-8
Purpose
Setting
Function
(Purpose)
Used to set the warm-up time display YES/NO.
Item
Operation
Warm-up is completed.
Press [CUSTOM SETTINGS] key.
8
8-1
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the operations of the 
developing voltage of each color and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
SIMULATION 7-6
INTERVAL AGING CYCLE SETUP. INPUT TIME AND PRESS START.
(1-999, UNIT: sec)
10
SIMULATION 7-8
WARM UP TIME DISPLAY. 
ARE YOU SURE?
1. YES
2. NO
1
Press [START] key, 
and time count is started.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARMING UP,PLEASE WAIT.
(UNIT:sec)
 30 
Press [CUSTOME SETTING] key, 
and time count is stopped.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARM UP COMPLETED.
(UNIT:sec)
 60 
: Feb. 9 2004
1
AR-M550/M620/M700  SIMULATION  8 - 28
Operation/Procedure
1) Enter the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the set
value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The main charger grid output voltage adjustment and output check
can be made in each print mode.)
Operation/Procedure
1) Enter the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the voltage corresponding to the set
value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The transfer output voltage adjustment and output check can be made
in each print mode.)
Item
Set range
Default
1
AUTO
Auto mode
0 - 750
495
2
CHARACTER
Text mode
3
MIX
Text/Photo mode
4
PHOTO
Photo mode
5
PRINTER
Printer mode
6
FAX
FAX mode
7
PLUS
Reverse developing
bias voltage
0 - 250
150
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Or after 30sec output.
8-2
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the main 
charger grid voltage in each printer mode and the 
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Set range
Default
1
AUTO
Auto mode
200 - 1000
580
2
CHARACTER
Text mode
3
MIX
Text/Photo mode
4
PHOTO
Photo mode
5
PRINTER
Printer mode
6
FAX
FAX mode
SIMULATION 8-1
1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO 
495
  2.CHARACTER 
495
3.MIX 
495
   4.PHOTO 
495
5.PRINTER 
495
  6.FAX 
495
  7.PLUS 
150
SIMULATION 8-1
DV BIAS SETTING. INPUT VALUE, AND PRESS START.
1:AUTO (0-750)
495
SIMULATION 8-1
DV BIAS SETTING. EXECUTING···.
1:AUTO
495
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Or after 30sec output.
8-6
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the transfer 
voltage and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)/Transfer
Item
Set 
range
Default
AR-M550N/U, 
AR-620N/U
AR-M700N/U
1
FRONT
Long side print 
mode
0 - 800
300
400
2
BACK
Back side print 
mode
300
400
SIMULATION 8-2
1
MAIN GRID SETTING. SELECT 1-6, AND PRESS START.
1.AUTO 
580
  2.CHARACTER 
580
3.MIX 
580
   4.PHOTO 
580
5.PRINTER 
580
  6.FAX 
580
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1.AUTO (200-1000)
580
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING···.
1.AUTO
580
1
1
1
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Press [START] key.
Press [CUSTOM SETTINGS] key. 
Or after 30sec output.
SIMULATION 8-6
1
THV+ SETTING. SELECT 1-2, AND PRESS START.
1.FRONT 
300
2.BACK  
300
SIMULATION 8-6
THV+ SETTING. INPUT VALUE, AND PRESS START.
1.FRONT(0-800)
300
SIMULATION 8-6
THV+ SETTING. EXECUTING···.
1.FRONT
300