1
AR-M550/M620/M700  SIMULATION  8 - 29
Operation/Procedure
1) Enter the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the voltage corresponding to the set
value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The transfer output voltage adjustment and output check can be made
in the transfer belt cleaning mode.)
Operation/Procedure
1) Select the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is saved in the memory and the voltage correspond-
ing to the set value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
Operation/Procedure (Not used)
1) Select the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
(The voltage is outputted for 30sec.)
When [CUSTOM SETTINGS] key is pressed, the operation can be
stopped. 
The output voltage can be adjusted with the adjustment volumes
VR101/VR102 on the high voltage PWB (fusing bias).
8-17
Purpose
Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the transfer 
voltage and the related circuit. (Transfer belt cleaning 
mode)
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Operation
Item
Set range
Default
1
SHF FRONT
AC component
0 - 450
450
2
SHV BACK
AC component
0 - 450
450
3
THV-
DC component
0 - 150
10
Press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
8-18
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the voltage of the transfer CL 
roller cleaning/transfer CL roller print mode and the 
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
1
1
SIMULATION 8-17
1
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1.SHV FRONT 
450
2.SHV BACK  
450
3.THV-  
10
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1.FRONT (0-600)
450
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING···.
1.FRONT(0-600)
450
1
(The output voltage of the transfer CL roller cleaning/transfer CL roller
print mode can be adjusted and checked.)
Item
Set range
Default
Transfer CL roller (Print)
CRHV PLUS
0 - 250
200
Transfer CL roller (Cleaning)
CRHV MINUS
0 - 250
200
Press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
8-19
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the fusing bias voltage and 
the control circuit. (Not used)
Section
Fusing
Item
Adjustment VR
Fusing bias (-)
FBIAS
VR 101
Fusing bias (+)
VR 102
Press [START] key.
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
1
1
SIMULATION 8-18
1
TRANSFER CLEANING ROLLER SETTING. SELECT 1-2, AND 
PRESS START.
1.CRHV PLUS    
200
 
2.CRHV MINUS   
200
SIMULATION 8-18
TRANSFER CLEANING ROLLER SETTING. INPUT VALUE, AND 
PRESS START.
1.CRHV PLUS (0-250) 
200
SIMULATION 8-18
TRANSFER CLEANING ROLLER SETTING. EXECUTING···.
1.CRHV PLUS(0-250)
200
1
SIMULATION 8-19
1
FUSING BIAS CHECK. SELECT 1, AND PRESS START. 
1.FBIAS
SIMULATION 8-19
FUSING BIAS CHECK.. EXECUTING···
1.FBIAS
: Feb. 9 2004
1
AR-M550/M620/M700  SIMULATION  8 - 30
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated.
Press [CUSTOM SETTINGS] key to stop the operation.
Operation/Procedure
The operating conditions of the sensors and detectors are displayed. 
The active sensors and detectors are highlighted.
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated for 10sec.
Press [CUSTOM SETTINGS] key to stop the operation.
NOTE: Do not execute this simulation with toner in the toner bottle and
the intermediate toner tank. Excessive toner may enter the
developing section, causing overtoner. Check that there is no
toner in the toner bottle and the intermediate toner tank or dis-
assemble the toner motor before executing this simulation.
Operation/Procedure
1) Press [START] key.
The toner motor rotates 2 turns, and the toner presence/empty in
the toner hopper is displayed. 
Toner empty: Normal display
Toner remained:  Highlighted display
9
9-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the load 
(clutch/solenoid) in the duplex section and the control 
circuit.
Section
Duplex
Item
Operation
1
ADUM1
ADU motor 1: Upstream
2
ADUM2
ADU motor 2: Downstream
3
DGS
ADU gate solenoid
Press [START] key.
Press [CUSTOM SETTINGS] key to stop 
the operations.
9-2
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of the sensors and 
detectors in the duplex section and its control circuit.
Section
Duplex
Item
Operation
DSW_ADU
ADU cabinet open/close detection
AINPD
ADU paper entry detection
APPD1
ADU transport detection 1
APPD2
ADU transport detection 2
SIMULATION 9-1
ADU OUTPUT CHECK. SELECT 1-3, AND PRESS START.
1. ADUM1
2. ADUM2
3. DGS
1
SIMULATION 9-1
ADU OUTPUT CHECK. EXECUTING···.
1. ADUM1
2. ADUM2
3. DGS
1
SIMULATION 9-2
ADU SENSOR CHECK.
DSW_ADU  
AINPD
  APPD1  APPD2
10
10-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of the toner motor and 
the related circuit.
Section
Process (Developing)
Item
Operation
TM1
Toner motor 1
TM2
Toner motor 2
Press [START] key.
Press [CUSTOM SETTINGS] key to stop 
the operations. Or after 10sec.
10-2
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of the toner remaining 
quantity sensor and the related circuit.
Section
Process (Developing)
Item
Operation
Press [START] key.
Press [CUSTOM SETTINGS] key to stop the 
operation immediately, or after ** 
SIMULATION 10-1
TONER MOTOR ACTIVATION. SELECT 1-2, AND PRESS START
1. TM1
2. TM2
1
SIMULATION 10-1
TONER MOTOR ACTIVATION. EXECUTING···.
1. TM1
2. TM2
1
SIMULATION 10-2
TONER REST SENSOR CHECK. PRESS START.
TFSD
SIMUL ATION 10-2
TONER REST SENSOR CHECK. EXECUTING···.
TFSD
: Feb. 9 2004
1
AR-M550/M620/M700  SIMULATION  8 - 31
Operation/Procedure
1) Select 1 (YES) with 10-key.
2) Press [START] key. (The trouble display is canceled.)
Operation/Procedure
1) Select 1 (YES) with 10-key.
2) Press [START] key. (The trouble display is canceled.)
Operation/Procedure
1) Select 1 (YES) with 10-key. 
2) Press [START] key. (The trouble display is canceled.)
Operation/Procedure
1) Select 1 (YES) with 10-key.
2) Press [START] key. (The trouble display is canceled.)
Operation/Procedure
1) Select 1 (YES) with 10-key. 
2) Press [START] key. (The trouble display is canceled.)
13
13-0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel the self-diag "U1" trouble. (Only when 
FAX is installed.)
Section
FAX
Item
Trouble
1
YES
After canceling U1 trouble, the machine returns to the 
main code entry standby mode.
2
NO
Without canceling U1 trouble, the machine returns to 
the main code entry standby mode.
14
14-0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel excluding the self-diag U1/LCC/U2/PF 
troubles.
Item
Trouble
Error
1
YES
After canceling the trouble other than U1, U2, PF, and 
LCC, the machine returns to the main code entry 
standby mode.
2
NO
Without canceling the trouble, the machine returns to 
the main code entry standby mode.
15
15-0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel the self-diag "U6-09, F3-12, 22" (large 
capacity paper feed tray, paper feed trays 1, 2) 
troubles.
Section
LCC
Item
Trouble
SIMULATION 13
U1 TROUBLE CANCELLATION. 
ARE YOU SURE?
1. YES
2. NO
1
1
SIMULATION 14
TROUBLE CANCELLATION. (OTHERS)
ARE YOU SURE?
1. YES
2. NO
1
1
YES
After canceling the LCC trouble, the machine returns 
to the main code entry standby mode.
2
NO
Without canceling the trouble, the machine returns to 
the main code entry standby mode.
16
16-0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel the self-diag U2 troubles.
Section
MFP control PWB, PCU PWB, scanner control PWB
Item
Trouble
1
YES
After canceling the U2 trouble, the machine returns to 
the main code entry standby mode.
2
NO
Without canceling the trouble, the machine returns to 
the main code entry standby mode.
17
17-0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel the PF troubles (when the copy inhibit 
command from the host computer is received).
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Trouble
Error
1
YES
After canceling the PF trouble, the machine returns to 
the main code entry standby mode.
2
NO
Without canceling the trouble, the machine returns to 
the main code entry standby mode.
SIMULATION 15
LCC TROUBLE CANCELLATION.
ARE YOU SURE?
1. YES
2. NO
1
SIMULATION 16
U2 TROUBLE CANCELLATION.
ARE YOU SURE?
1. YES
2. NO
1
SIMULATION 17
PF TROUBLE CANCELLATION.
ARE YOU SURE?
1. YES
2. NO
1
: Feb. 9 2004
1
AR-M550/M620/M700  SIMULATION  8 - 32
Operation/Procedure
1) Enter the number corresponding to the maintenance timing dis-
play. 
2) Press [START] key. The condition entered in procedure 1) is set.
Operation/Procedure
Various print counter values are displayed.
Operation/Procedure
The paper jam/trouble counter value is displayed.
Operation/Procedure
The history of paper jams and misfeed is displayed. 
The misfeed history is displayed sequentially from the latest one. The
max. 100 items of misfeed history can be recorded. The data may be
used to identify trouble position. 
The latest 100 items of paper jam history are displayed. (Refer to the
jam cause code table below.)
(Jam cause code)
21
21-1
Purpose
Setting
Function
(Purpose)
Used to set the maintenance cycle.
Item
Specifications
Counter
Maintenance timing display
Set range
0
Default (Differs depending on the model.)
0 - 999
1 - 300
Maintenance display at 1K - 300K
999
No maintenance display
22
22-1
Purpose
Adjustment/Setup/Operation data output/Check 
(Display/Print)
Function
(Purpose)
Used to check the print count value in each section 
and each operation mode. (Used to check the 
maintenance timing.)
Section
Item
Counter
TOTAL
Total counter
DRUM
Drum counter
TONER
Toner counter
DEVE
Developer counter
MAINTENANCE
Maintenance counter
TOTAL OUTPUT
Total output quantity
COPIES
Copy effective paper counter
PRINTER
Printer counter
FAX
FAX print counter
I-FAX OUTPUT
iFAX print counter
DOC FILING OUTPUT
Document filing print counter
RIIGHT SIDE OUTPUT
Right paper exit counter
OTHERS
Other print counter (List print , etc.)
SIMULATION 21-1
MAINTENANCE CYCLE SETUP. INPUT VALUE 0-999, AND PRESS
START.
 0:     DEFAULT
 1-300: MAINTENANCE CYCLE (1K-300K)
 999:   FREE
0
SIMULATION 22-1
COUNTER DATA DISPLAY.
TOTAL: ********  DRUM: ********  TONER: ******** 
DEVE: ********   MAINTENANCE: ********
TOTAL OUTPUT: ********  COPIES: ******** 
PRINTER: ********       FAX OUTPUT: ******** 
I-FAX OUTPUT:********   DOC FILING OUTPUT:********
RIGHT SIDE:********     OTHERS: ********
22-2
Purpose
Adjustment/Setup/Operation data output/Check 
(Display/Print)
Function
(Purpose)
Used to check the total numbers of misfeed and 
troubles. (When the number of misfeed is considerably 
great, it is judged as necessary for repair. The misfeed 
rate is obtained by dividing this count value with the 
total counter value.)
Item
Trouble
PAPER JAM
Number of paper jams
SPF JAM
Number of SPF jams
TROUBLE
Number of troubles
22-3
Purpose
Adjustment/Setup/Operation data output/Check 
(Display/Print)
Function
(Purpose)
Used to check misfeed positions and the misfeed 
count of each position. (If the misfeed count is 
considerably great, it may be judged as necessary to 
repair.)
Section
Sections other than SPF/DSPF section
Item
Trouble
Misfeed
Code
Description
NO_JAM_CAUSE
No jam. Also used to cancel a jam. 
TRAY1
Tray 1 paper feed jam (PFD2 not-reached)
PFD2_NM1
PFD2 not-reached jam (Tray 3 feed paper)
PFD2_NM2
PFD2 not-reached jam (Tray 4 feed paper)
PFD2_NAD
PFD2 not-reached jam (ADU re-feed paper)
PFD2_ST1
PFD2 remaining jam (Tray 1 feed paper)
PFD2_SM1
PFD2 remaining jam (Tray 3 feed paper)
PFD2_SM2
PFD2 remaining jam (Tray 4 feed paper)
PFD2_SAD
PFD2 remaining jam (ADU re-feed paper)
PPD_NMF
PPD1 not-reached jam (Manual feed tray feed 
paper)
PPD_NT1
PPD1 not-reached jam (Tray 1 feed paper)
PPD_NT2
PPD1 not-reached jam (Tray 2 feed paper)
PPD_NM1
PPD1 not-reached jam (Tray 3 feed paper)
PPD_NM2
PPD1 not-reached jam (Tray 4 feed paper)
PPD_NLC
PPD1 not-reached jam (LCC paper feed paper)
PPD_NAD
PPD1 not-reached jam (ADU re-feed paper)
PPD_SMF
PPD1 remaining jam (Manual feed tray feed 
paper)
PPD_ST1
PPD1 remaining jam (Tray 1 feed paper)
PPD_ST2
PPD1 remaining jam (Tray 2 feed paper)
PPD_SM1
PPD1 remaining jam (Tray 3 feed paper)
SIMULATION 22-2
JAM/TROUBLE COUNTER DATA DISPLAY.
PAPER JAM: ********   SPF JAM: ********
TROUBLE: ********
1
1
1
1
Page of 97
Display