DOWNLOAD Sharp AR-M35 / AR-M450 (serv.man7) Service Manual ↓ Size: 642.38 KB | Pages: 40 in PDF or view online for FREE

Model
AR-M35 AR-M450 (serv.man7)
Pages
40
Size
642.38 KB
Type
PDF
Document
Handy Guide
Brand
Device
Copying Equipment / ARM350 450 ARP350 450 Handy Guide (NEW)
File
ar-m35-ar-m450-sm7.pdf
Date

Sharp AR-M35 / AR-M450 (serv.man7) Handy Guide ▷ View online

 
Test Simulation 
 
 
Version 2.0 
Issue 01/02 
 
17 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS SUPPORT 
TECHNICAL SERVICES GROUP
 
 
AR-M350/450
 
Test 
Command 
Sub Code 
Default 
Setting 
 
Description 
 
01 
 
Main unit sensor check 
30 
02 
 
Tray sensor check 
40 
-- 
 
Bypass tray sensor check 
 
01 
 
Bypass tray size sensor check 
 
02 
 
Bypass tray adjustment 
 
07 
 
Bypass width detection level set up 
 
11 
 
Bypass width detection check 
 
12 
 
Bypass width detection adjust (Multi-Purpose Tray) 
41 
-- 
 
Original size detection (OC mode) 
 
01 
 
PS sensor check 
 
02 
 
PS sensor adjustment 
 
03 
 
PS sensor output display 
43 
01 
 
Fuser temperature set up 
44 
-- 
 
Process control mode 
 
01 
 
Correction mode setting 
 
04 
 
PC initial density set up (drum type B) 
 
09 
 
PC data display 
46 --  
Exposure 
adjustment 
 
02 
 
Adjust copy density in copy mode 
 
09 
 
Adjust print density in copy/text mode 
 
10 
 
Adjust print density in copy/text/photo mode 
 
11 
 
Adjust print density in copy/photo mode 
 
12 
 
Adjust print density in fax mode ( all modes) 
 
13 
 
Adjust print density in fax mode (normal) 
 
14 
 
Adjust print density in fax mode (small text) 
 
15 
 
Adjust print density in fax mode (fine text) 
 
16 
 
Adjust print density in fax mode (super-fine) 
17 
 
Adjust shading correction 
18 
 
Adjust gamma density gradient in copy mode 
 
19 
 
Adjust gamma in auto copy mode 
46 
20 
 
Adjust copy density in DSPF 
 
21 
 
Adjust scanner exposure level 1 mode auto 
 
22 
 
Adjust scanner exposure level normal  
 
23 
 
Adjust scanner exposure level small text  
 
24 
 
Adjust scanner exposure level fine mode 
 
25 
 
Adjust scanner exposure level super-fine 
48 01  
Magnification 
adjustment 
 
05 
 
Adjust exposure motor speed 
50 
-- 
 
Lead edge registration 
 
01 
 
Lead edge adjustment value (copy) 
 
02 
 
Lead edge adjustment value (calculation) 
 
06 
50 
Lead edge adjustment DSPF 
 
07 
50 
Lead edge adjustment DSPF (simple) 
 
10 
50 
Print centre deviation adjustment. 
 
12 
50 
Original centre deviation adjustment. 
51 
02 
50 
Resist roller adjustment value 
53 
-- 
 
Document Feeder adjustments 
 
06 
 
Adjusts DSPF width detection 
 
Test Simulation 
 
 
Version 2.0 
Issue 01/02 
 
18 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS SUPPORT 
TECHNICAL SERVICES GROUP
 
 
AR-M350/450
 
Test 
Command 
Sub Code 
Default 
Setting 
 
Description 
 
07 
 
Value entry for DSPF width detection 
60 01  
DRAM 
test 
61 
-- 
 
Laser unit  
 
01 
 
Scanner operational check 
 
02 
 
Adjust scanner laser power in copy mode 
 
03 
 
Adjust scanner laser power in fax mode  
 
04 
 
Adjust scanner laser power in print mode 
62 --  
Hard 
drive 
 
02 
 
HDD read/write test partial check 
 
03 
 
HDD read/write test all area check 
63 
01 
 
CCD shading data display 
 02 
 
Executes 
shading 
 
07 
 
Adjust the white plate scanning start position  
64 01  
Self 
print 
65 --  
Touch 
panel 
 
01 
 
Touch panel adjustment 
 
02 
 
Touch panel test 
66 
-- 
 
Fax soft switches 
67 
02 
 
Printer Parallel I/F operation check 
 
11 
 
Used to set printer I/F select in signal 
67 
16 
 
Used to check the operation of the network card 
 
 
Test Simulation 
 
 
Version 2.0 
Issue 01/02 
 
19 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS SUPPORT 
TECHNICAL SERVICES GROUP
 
 
AR-P350 Diagnostic Mode Notes. 
Diagnostic Mode Entry
  
 
When the scanner unit is not installed, the machine can be checked and tested with the following diagnostics mode. 
To cancel diagnostic mode, turn the power off. 
 
 
 Hold 
the 
MENU
 and OK keys down whilst turning on the main power switch
 
 
Machine Data Print 
 
 
1.  In diagnostic mode press MENU 12 times to display Test print 00 
2. 
Press OK. The machine will enter warm up mode with no indication on the display. 
3.  Multi setting. 
Use 
tuto select the number of copies required. 
4. MENU
Print pattern. Use 
tuto select the test pattern required. 
PP1 
Centre line for centre alignment checks 
PP2 
Half tone full page coverage for image loss checks. 
PP65  Pattern test for laser focus checks. 
PP66  Laser write pattern 
PP67  Laser write pattern 
PP68  Laser write pattern 
PP70  Alignment scale test chart 
PP71  All square pattern 
PP72 Diagonal 
pattern 
PP73 Diagonal 
pattern 
PP74 Diagonal 
pattern 
PP75  ID patch print 
PP87  Sharp test sheet B 
PP88  Ageing chart 6% toned area 
PP89   Ageing chart 5% toned area 
PP98  Machine data print out (SIM 22 – 06) 
5.  MENUCassette. Use 
tuto select the paper source. (Note BPT = MFT) 
6.  MENUDuplex. Use 
tuto select Duplex mode. 
7.  MENUOutput. Use 
tuto select the type of output dependent on the options fitted  . 
8. Press 
OK 
for test prints. 
 
 
 
 
Note: If the scanner unit is installed this mode does not work. 
 
Notes 
A) 
The OK key can be pressed at any time for the machine to produce a test print. However, if OK is pressed 
and the data light remains flashing and no print is produced check the type of output selected. It may be 
that the optional unit required for that type of output is not installed. For example BIN # selected with no 
AR-MS1 installed. 
B) 
  Pressing the Information key will return to the previous Menu item. 
For example, return from Output to Duplex press INFORMATION. 
 
C) Pressing 
BACK/C 
to the main menu item. 
For example, in Output press BACK/C returns to Test Print 0 
 
 
Test Simulation 
 
 
Version 2.0 
Issue 01/02 
 
20 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS SUPPORT 
TECHNICAL SERVICES GROUP
 
 
 
 
LCD Display 
Menu 
PCU DIAG MODE # 
Diag mode initial display 
SENSOR CHECK XX 
Sensor check mode 
LASER SYSTEM CHECK 
LSU Test 
LED/LCD TEST 
LED/LCD Test 
HV TEST XXX 
High Voltage Board Test 
LOAD TEST XX 
Operation test mode 
AUTOMATIC DV ADJ 
Auto Developer Adjustment 
LASER OUTPUT SETUP (XXX) 
Laser output setup 
FUSER TEMP SETTING X 
Fusing temperature setup 
SLOW UP SETTING 
Process control value setup 
SIZE ADJUSTMENT X (A=Multipupose Tray) 
Paper feed size setup 
ICU PRINT MODE SET 
ICU print mode setup 
TEST PRINT XX 
Test Print 
WARM UP TIME DISPLAY 
Warm-up time display 
COUNTER DISPLAY 
Counter Display 
COUNTER CLEAR 
Counter Clear 
TROUBLE CANCEL X 
Trouble Cancel 
XXX SIZE SETUP 
Paper feed tray size setup 
DESTINATION SETUP 
Destination setup 
TRAY DETECT TYPE XX 
Paper feed tray paper type setup 
CE MARK SETTING 
CE Mark setup 
COUNTUP MODE SETUP X 
A3 count mode setup 
MNT CYCLE SETUP 
Maintenance cycle setup 
LIFE OVER SETTING 
Operation at life over setup 
FINISHER JOGGER ADJ. 
Finisher jogger adjustment 
CONSOLE FIN. SET X 
Console finisher setup 
MEMORY MODE SETTING 
Trouble memory mode setup 
LAST JAM CODE DISP 
Last jam code display 
SYSTEM INFORMATION X 
System information display 
PROCESS DATA DISP X 
Process control data display 
CENTRO PORT CHECK 
Parallel port Check 
SELECT IN SIGNAL SET 
Select in signal setup 
 
 
 
 
Page of 40
Display

Click on the first or last page to see other AR-M35 / AR-M450 (serv.man7) service manuals if exist.