DOWNLOAD Sharp AR-M316 (serv.man10) Service Manual ↓ Size: 14.14 MB | Pages: 127 in PDF or view online for FREE

Model
AR-M316 (serv.man10)
Pages
127
Size
14.14 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARM256 316 Service Manual
File
ar-m316-sm10.pdf
Date

Sharp AR-M316 (serv.man10) Service Manual ▷ View online

AR-M256/M257/M258/M316/M317/M318/5625/5631  SIMULATION 8 - 51
Operation/procedure
Press the [START] key.
The confidential ID table (confidential BOX numbers, confidential BOX
names, and confidential password) is printed. 
The confidential data of My company mode is printed separately.
Note: Executable only when the FAX is installed.
Operation/procedure
Press the [START] key.
Used to input all image data (including confidential reception data,
remote send image, not-sent image) stored in image memory of the
FAX section.
The output image is remained even after outputting.
Note: Executable only when the FAX is installed.
Operation/procedure
Select “1: YES” with the 10-key and press the [START] key. (When “2:
NO” is selected, the simulation is canceled.)
Used to clear all image data (including confidential reception data)
stored in image memory of the FAX section.
The management table is also cleared (initialized) at the same time.
* lIf there is any print data, the power must be turned off after clearing.
Note: Executable only when the FAX is installed.
Operation/procedure
Select the signal number with the 10-key, and press the [START] key.
By setting the signal number, the specified signal is delivered to the
line at the speed of 300bps. (The signal is continuously sent until the
interruption command is provided by pressing the [CUSTOM SET-
TINGS] key.)
The signal send level can be selected from 0dB or the soft SW set value.
The signal send level is returned to the soft SW set value before execu-
tion of the mode after completion of the mode.
By entering the number and pressing the [START] key during execu-
tion, the signal kind can be changed.
Note: Executable only when the FAX is installed.
66-6
Purpose
Data output, check
Function (Purpose)
Printing the confidential password
Section
FAX
Item
Data Confidential/Pass 
code
66-7
Purpose
Data output, check
Function (Purpose)
Print the screen memory contents
Section
FAX
Item
Data Image 
data
 
1
 
1
66-10
Purpose
Adjustment/Setting/Check
Function (Purpose)
Image data memory clear
Section
FAX
Item
Data
Image data
66-11
Purpose
Operation test/check
Function 
(Purpose)
Used to send 300bps signals. 
(Signal send level: Max.)
Section
FAX
Item
Operation
Item
1
NO SIGNAL
2
11111
3
11110
4
00000
5
010101
6
00001
1
1
AR-M256/M257/M258/M316/M317/M318/5625/5631  SIMULATION 8 - 52
Operation/procedure
Select the signal number with the 10-key, and press the [START] key.
By setting the signal number, the specified signal is delivered to the
line at the speed of 300bps. (The signal is continuously sent until the
interruption command is provided by pressing the [CUSTOM SET-
TINGS] key.)
The signal send level can be selected from 0dB or the soft SW set value.
The signal send level is returned to the soft SW set value before execu-
tion of the mode after completion of the mode.
By entering the number and pressing the [START] key during execu-
tion, the signal kind can be changed.
Note: Executable only when the FAX is installed.
Operation/procedure
Enter the number with the 10-key, [*] key, and [#] key.
Press the [CLEAR] key to return to the initial state.
Press the [START] key to register the entered number.
Note: Executable only when the FAX is installed.
Operation/Procedure
1.
Select the item with the 10-key, and press the [START] key.
2.
Set the make time with the 10-key.
The dial is sent with the set value + 26ms. 
The sending dial cannot be interrupted.
Note: Executable only when the FAX is installed.
Operation/Procedure
1.
Select the item with the 10-key, and press the [START] key.
2.
Set the make time with the 10-key.
The dial is sent with the set value + 26ms. 
The sending dial cannot be interrupted.
Note: Executable only when the FAX is installed.
66-12
Purpose
Operation test/check
Function 
(Purpose)
Used to send 300bps signals. 
(Signal send level: Set by soft SW)
Section
FAX
Item
Operation
Item
1
NO SIGNAL
2
11111
3
11110
4
00000
5
010101
6
00001
66-13
Purpose
Setting
Function (Purpose)
Used to register the dial numbers.
Section
FAX
Item
Operation
 
1
 
66-14
Purpose
Operation check/test
Function 
(Purpose)
Used to perform the dial test. (10 PPS send test)
Section
FAX
Item
Operation
Item
Content
Setting range
0
EXECUTE
Execution
1
MAKE TIME
Dial pulse make time setting
0-15
66-15
Purpose
Operation check/test
Function 
(Purpose)
Used to perform the dial test. (20 PPS send test)
Section
FAX
Item
Operation
Item
Content
Setting range
0
EXECUTE
Execution
1
MAKE TIME
Dial pulse make time setting
0-15
1
1
AR-M256/M257/M258/M316/M317/M318/5625/5631  SIMULATION 8 - 53
Operation/Procedure
1.
Select the item with the 10-key, and press the [START] key.
2.
Enter the set value with the 10-key.
The sending dial cannot be interrupted.
3.
Select the soft SW reflection.
Note: Executable only when the FAX is installed.
Operation/procedure
Enter the DTFM signal (1 digit (1 to 9, 0, *, #)) and press the [START] key. 
When the [CUSTOM SETTINGS] key is pressed during execution, the
simulation is terminated.
Note: Executable only when the FAX is installed.
Operation/Procedure
Enter the DTFM signal (1 digit (1 to 9, 0, *, #)) and press the [START] key.
When the [CUSTOM SETTINGS] key is pressed during execution, the
simulation is terminated.
Note: Executable only when the FAX is installed.
Operation/Procedure
Select “1: YES” with the 10-key, and press the [START] key. The data
are backed up. (When “2: NO” is selected, the simulation is canceled.)
* The AR-FX5 data cannot be written into the AR-FX7. If it is exe-
cuted, data are initialized and deleted. In addition, the AR-FX7 data
cannot be used in the AR-FX5.
Note: Executable only when the FAX is installed.
Operation/Procedure
Select “1: YES” with the 10-key, and press the [START] key. The Flash
ROM data are read out and written into the SRAM. (When “2: NO” is
selected, the simulation is canceled.)
* The AR-FX5 data cannot be written into the AR-FX7. If it is exe-
cuted, data are initialized and deleted. In addition, the AR-FX7 data
cannot be used in the AR-FX5.
Note: Executable only when the FAX is installed.
Operation/procedure
1.
Select the item to be printed.
2.
Press the [START] key.
The information of the selected item is printed. 
Note: Executable only when the FAX is installed.
66-16
Purpose
Operation check/test
Function 
(Purpose)
Used to perform the dial test. (DTFM signal send test)
Section
FAX
Item
Operation
Item
Content
Setting 
range
0
EXECUTE
Execution
1
HIGH (SW)
High group
0-15
2
HIGH-LOW (SW)
High group, Low group
0-15
Item
Content
1
NO STORE TO SW
Not reflected.
2
STORE TO SW
Reflected. (Shift SW value changed.)
66-17
Purpose
Operation check/test
Function 
(Purpose)
Used to check the DTFM signal send operation. 
(Signal send level: Max.)
Section
FAX
Item
Operation
66-18
Purpose
Operation check/test
Function 
(Purpose)
Used to check the DTFM signal send operation. 
(Signal send level: Set by soft SW.)
Section
FAX
Item
Operation
1
66-19
Purpose
Back up
Function 
(Purpose)
Used to write the SRAM data to the Flash ROM. 
Section
FAX
Item
Data
66-20
Purpose
Back up
Function 
(Purpose)
Used to write the Flash ROM data to the SRAM.
Section
FAX
Item
Data
66-21
Purpose
Check
Function (Purpose)
FAX information print
Section
FAX
Item
Data
Item
Content
1
USER SW.LIST
User setting list
2
SOFT SW.LIST
Soft SW list
3
SYSTEM ERROR
System error list
Used to print the system error log (error 
number and time).
4
PROTOCOL
Protocol error list
Regardless of soft SW38-1 status, the 
protocol monitor of the preceding 
communication is printed. (Printing is 
allowed at any time before starting the 
next communication.) For this operation, 
the protocol monitor of one 
communication is always buffered.
 
AR-M256/M257/M258/M316/M317/M318/5625/5631  SIMULATION 8 - 54
Operation/procedure
Select “1: YES” with the 10-key and press the [START] key. The FAST
storage data are cleared. (When “2: NO” is selected, the simulation is
canceled.)
Note: Executable only when the FAX is installed.
Operation/procedure
When the relay state of the polarity reverse relay, the handset hook
switch, or the external telephone hook switch is changed, the content
of change is displayed regardless of the soft SW setup (real time). The
display of change is kept until an interruption command is supplied by
pressing the [CUSTOM SETTINGS] key. 
Note: Executable only when the FAX is installed.
Operation/Procedure
1.
Enter the set value. (Valid only 0 to 8)
2.
The entered bit is alternatively switched between “0” and “1” and
the target signal name is highlighted.
3.
Press the [START] key to send the signal. 
When the [CUSTUM SETTINGS] key is pressed, the output is terminated.
Note: Executable only when the FAX is installed.
Operation/procedure
The fixed data received from the line are checked and the result is displayed. 
When data are coincident, “OK” is displayed. When not, “NG” is displayed. 
Note: Executable only when the FAX is installed.
Operation/Procedure
Signal detection is checked and the result is displayed. 
Note: Executable only when the FAX is installed.
Operation/procedure
The send/receive test is performed, and the time required for send/
receive of the image data in the test is measured and displayed.
66-24
Purpose
Data clear
Function 
(Purpose)
Used to clear the FAST storage data. (SEC only)
Section
FAX
Item
Data Initializing
66-30
Purpose
Operation test/check
Function (Purpose)
Used to set the TEL/LIU.
Section
FAX
Item
Operation
Item
Notification contents
Signal low
Signal high
HS2
ON
OFF
HS1
ON
OFF
RHS
ON
OFF
EXHS
ON
OFF
66-31
Purpose
Setting
Function (Purpose)
Used to set the TEL/LIU.
Section
FAX
Item
Operation
66-32
Purpose
Operation test/check
Function (Purpose)
Receive data check
Section
FAX
Item
Operation
66-33
Purpose
Operation test/check 
Function (Purpose)
Signal detection check 
Section
FAX
Item
Operation
66-34
Purpose
Operation test/check 
Function (Purpose)
Communication time measurement display
Section
FAX
Item
Operation
Setup on the user 
side when executing 
communication
Communication 
means
Picture quality
Density
ECM
Sender information
: Memory send
: Normal Character
: Lighter
: ON
: OFF
Measuring 
range
Send
From flag reception before sending of image 
data until sending of RCP frame
Receive
From flag reception before reception of 
image data until reception of RCP frame
Mode when measuring
Used to make communication not in a 
simulation process but in the normal screen 
and measure the time.
00001
1   2   3   4   5
Page of 127
Display