AR-M256/M257/M258/M316/M317/M318/5625/5631  SIMULATION 8 - 31
Operation/procedure
The operation status of the sensors and detectors in the original size
detection section are displayed. The active sensors and detectors are
highlighted.
For AB series, PD1 to 5 is displayed, for inch series, PD1 to 4.
Operation/procedure
Place an A3 (or WLT) document on the document table, and press
[START] key with the OC cover open.
The adjustment is performed and the result is displayed.
The value in [ ] shows the threshold value. (Hexadecimal display)
For AB series, 1 to 5 is displayed, for inch series, 1 to 4.
During execution of the simulation, “EXECUTING” is displayed.
Operation/procedure
The detection output level of each sensor is displayed in real time.
The value in [ ] shows the threshold value of 20 degree detection
adjustment. (Hexadecimal display)
For AB series, 1 to 5 is displayed, for inch series, 1 to 4.
Operation/procedure
Set the OC cover at 20 degrees detection and press the [START] key.
The detection output level of each sensor is displayed in real time.
The value in [ ] shows the threshold value of 20 degree detection
adjustment. (Hexadecimal display)
For AB series, 1 to 5 is displayed, for inch series, 1 to 4.
During execution, [EXECUTING] is highlighted.
41
41-1
Purpose
Operation test/check
Function 
(Purpose)
Used to check the document size detection photo 
sensor.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
PD1 to 5
Original sensor status
Without original: Normal display
With original: Highlighted display
41-2
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the detection level of the document size 
photo sensor.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection level (Hexadecimal display)
41-3
Purpose
Operation test/check
Function 
(Purpose)
Used to check the light reception level and the 
detection level of the original size detection photo 
sensor.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection level (Hexadecimal display)
41-4
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the detection level of OC 20 degrees.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection level (Hexadecimal display)
AR-M256/M257/M258/M316/M317/M318/5625/5631  SIMULATION 8 - 32
Operation/procedure
1.
Touch the item to be set. 
2.
Enter the set value with the 10-key.
Operation/procedure
Input the set value with the 10-key and press the [START] key.
43
43-1
Purpose
Setting
Function 
(Purpose)
Used to set the fusing temperature in 600dpi, 1200dpi, 
or postcard print.
Section
Fixing (Fusing)
Item
Operation
Item
Content
Setting 
range
Default 
(North 
America
/Others)
(Europe/
China)
1
Ready 
Temp Main 
(145)
Ready 
temperature Main 
(145mm/s)
150 - 
220
185
190
2
Ready 
Temp Sub 
(145)
Ready 
temperature Sub 
(145mm/s)
150 - 
220
180
185
3
Ready 
Temp Main 
(122)
Ready 
temperature Main 
(122mm/s)
150 - 
220
175
180
4
Ready 
Temp Sub 
(122)
Ready 
temperature Sub 
(122mm/s)
150 - 
220
170
175
5
WarmUp 
Target Main 
(145)
Warmup target 
temperature Main 
(145mm/s)
150 - 
220
185
6
WarmUp 
Target Sub 
(145)
Warmup target 
temperature Sub 
(145mm/s)
150 - 
220
180
7
WarmUp 
Target Main 
(122)
Warmup target 
temperature Main 
(122mm/s)
150 - 
220
175
8
WarmUp 
Target Sub 
(122)
Warmup target 
temperature Sub 
(122mm/s)
150 - 
220
170
9
WarmUp 
Temp Main 
(145)
Warmup 
complete 
temperature Main 
(145mm/s)
0 - 40
10
10
WarmUp 
Temp Sub 
(145)
Warmup 
complete 
temperature Sub 
(145mm/s)
0 - 40
15
11
WarmUp 
Temp Main 
(122)
Warmup 
complete 
temperature Main 
(122mm/s)
0 - 40
10
12
WarmUp 
Temp Sub 
(122)
Warmup 
complete 
temperature Sub 
(122mm/s)
0 - 40
15
13
600dpi 
Main (145)
600dpi Main 
(145mm/s)
150 - 
220
190
195
14
600dpi Sub 
(145)
600dpi Sub 
(145mm/s)
150 - 
220
190
195
15
POST 
CARD 
Main (145)
Postcard Main 
(145mm/s)
150 - 
220
200
16
POST 
CARD Sub 
(145)
Postcard Sub 
(145mm/s)
150 - 
220
200
17
CARDBOA
RD Main 
(145)
Thick paper Main 
(145mm/s)
150 - 
220
200
18
CARDBOA
RD Sub 
(145)
Thick paper Sub 
(145mm/s)
150 - 
220
200
19
600dpi 
Main (122)
600dpi Main 
(122mm/s)
150 - 
220
175
185
20
600dpi Sub 
(122)
600dpi Sub 
(122mm/s)
150 - 
220
175
185
21
CARDBOA
RD Main 
(122)
Postcard Main 
(122mm/s)
150 - 
220
190
22
POST 
CARD Sub 
(122)
Postcard Sub 
(122mm/s)
150 - 
220
190
23
POST 
CARD 
(122mm/s)
Thick paper Main 
(122mm/s)
150 - 
220
190
24
CARDBOA
RD Sub 
(122)
Thick paper Sub 
(122mm/s)
150 - 
220
190
43-10
Purpose
Setting
Function 
(Purpose)
Used to set the paper feed cycle timing when printing 
postcards.
Section
Paper feed
Item
Operation
Setting range
1-99
Default
50
Item
Content
Setting 
range
Default 
(North 
America
/Others)
(Europe/
China)
 
 
 
 
 
 
 
 
 
 
 
SIMULATION 43-1 
 
AR-M256/M257/M258/M316/M317/M318/5625/5631  SIMULATION 8 - 33
Operation/procedure
Enter the set value with the 10-key, and press the [START] key.
Operation/procedure
1.
Select an item with 10-key, and press [START] key.
2.
Enter the setting value, and press [START] key.
Operation/procedure
1.
Select an item with 10-key, and press [START] key.
2.
Enter the setting value, and press [START] key.
Operation/procedure
The following data are displayed.
44
44-1
Purpose
Setting
Function 
(Purpose)
Used to make various setups in each mode of process 
control.
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Item
Content
Default
1
ENVIRONMENT 
ADJ.
Environmental correction Allow/ 
Inhibit (0: Inhibit, 1: Allow)
1
2 DUPLEX PRINT ADJ. 
Duplex print correction Allow/ 
Inhibit (0: Inhibit, 1: Allow)
0
44-2
Purpose
Setting
Function 
(Purpose)
Used to set the drum count correction. 
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Item
Content
Default
1
DRUM ADJUST
Drum count correction 
Disable/Enable 
(0: Disable, 1: Enable)
0
2
DRUM COUNT 
(31)
The drum count value is set 
for the LD power for 31 sheet 
model. 
(Setting in the unit of 1K) 
(Setting range: 1-100)
100
3
DRUM COUNT 
(25)
The drum count value is set 
for the LD power for 25 sheet 
model. 
(Setting in the unit of 1K) 
(Setting range: 1-100)
75
 
 
 
 
 
 
SIMULATION 44-02 
44-3
Purpose
Setting
Function 
(Purpose)
Used to set the DV count correction.
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Item
Content
Default
1
DV ADJUST
DV count correction Disable/
Enable 
(0: Disable, 1: Enable)
0
2
DV COUNT (31)
The DV count value is set for 
correction of the Grid/DVB 
voltage. (31 sheet model)
(Setting in the unit of 1K) 
(Setting range: 1-100)
100
3
DV COUNT (25)
The DV count value is set for 
correction of the Grid/DVB 
voltage. (25 sheet model)
(Setting in the unit of 1K) 
(Setting range: 1-100)
75
44-9
Purpose
Adjustment/Setup/Operation data output/Check 
(Display/Print)
Function 
(Purpose)
Used to display the process control correction 
information. 
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Item
Content
Default
25cpm
31cpm
DRUM ADJUST
Drum count correction state
(0:OFF, 1:ON) *
0
0
DV ADJUST
DV count correction state
(0:OFF, 1:ON) *
0
0
TH AREA1
Current correction value of the 
environment correction area 1
(Grid/DVB correction)
76
126
TH AREA2
Current correction value of the 
environment correction area 2
(Grid/DVB correction)
26
76
TH AREA3
Current correction value of the 
environment correction area 3
(Grid/DVB correction)
0
0
TH AREA4
Current correction value of the 
environment correction area 4
(Grid/DVB correction)
0
0
 
 
 
 
 
 
SIMULATION 44-03 
AR-M256/M257/M258/M316/M317/M318/5625/5631  SIMULATION 8 - 34
• When each count correction setting is "enable" in Sim44-2/3 and
each correction is reaching specified count, these are displayed.
Operation/procedure
The following data are displayed.
* The value before entry of SIM is displayed. (It is not revised in real
time.)
If sim entry is just after power turned on, the display value is all 0.
Operation/procedure
Set a toner density control correction value of the specified DV count.
Operation/procedure
The following data are displayed. (The displayed value is the previous
print correction value.)
TH AREA5
Current correction value of the 
environment correction area 5
(Grid/DVB correction)
0
0
TH AREA6
Current correction value of the 
environment correction area 6
(Grid/DVB correction)
0
0
TH AREA7
Current correction value of the 
environment correction area 7
(Grid/DVB correction)
0
0
TH AREA8
Current correction value of the 
environment correction area 8
(Grid/DVB correction)
0
0
44-14
Purpose
Adjustment/Setup/Operation data output/Check 
(Display/Print)
Function 
(Purpose)
Used to display the environment (temperature, 
humidity) correction information.
Item
Operation
TH AREA
Current environment area
TMP DATA
Detection temperature of sensor (C°)
HUD DATA
Detection humidity of sensor (%)
Item
Content
Default
25cpm
31cpm
SIMULATION 44-9 
SIMULATION 44-14 
44-16
Purpose
Setting
Function 
(Purpose)
The correction value for the toner density reference 
value corresponding to the DV count value is set 
individually for 145mm/s and 122mm/s (for the 31-
sheet machine and the 25-sheet machine).
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Item
Content
Default
1
0K
Toner concentration control 
correction value 
(145mm/s of 31-sheet model)
55
2
2K 
3
4K
4
10K
5
20K
6
40K
7
60K
8
80K
9
100K
10 0K
Toner concentration control 
correction value 
(122mm/s of 25-sheet model)
60
11 2K 
12 4K
13 10K
14 20K
15 40K
16 60K
17 80K 
18 100K
19 0K
Toner concentration control 
correction value 
(122mm/s of 31-sheet model)
50
20 2K 
21 4K
22 10K
23 20K
24 40K
25 60K
26 80K 
27 100K
44-17
Purpose
Adjustment/Setup/Operation data output/Check 
(Display/Print)
Function 
(Purpose)
Used to display the toner density control reference 
value.
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
TARGET
Toner concentration control reference value
DEV REF
Developer adjustment value
LIFE
Toner container life correction value (SIM 44-16)
 
 
 
 
 
 
 
 
 
 
 
 
SIMULATION 80-19 
 
Page of 127