AR-FX9  FAX SOFT SWITCH  4 - 25
SW29 No.5–No.8 Setup of number of times of call rings
Used to set the number of calls before starting reception in auto
receive mode.
Setting is made in binary input.
Default: 2 times
SW30 No.1 Report output when canceling
Used to set whether the user cancel report is outputted or not when
send is canceled during document send.
Default: 0 (Not output)
SW30 No.2–No.4 Inhibited to use
SW30 No.5 Default data, sender print
Used to set whether sender information (registered in the sender regis-
tration), sending date, and time are printed on the upper edge of send
document or not.
Default: 1 (ON)
SW30 No.6 Inhibited to use
SW30 No.7 Date/sender print position setup
Used to set whether date/sender information is printed inside the docu-
ment area or outside the document area.
Default: 0 (Outside of document)
SW30 No.8 Inhibited to use
SW31 No.1, No.2 Report output (in transmission)
Used to set whether communication report is outputted or not after
completion of sending (excluding sequential broadcast and sequential
send request).
Default: 1 0 (Only when transmission is failed.)
SW31 No.3, No.4 Report output (In broadcast and 
sequential send request)
Used to set whether communication report is outputted or not after
completion of sending (sequential broadcast and sequential send
request).
Default: 0 1 (All print)
SW31 No.5, No.6 Report output (in reception)
Used to set whether communication report is outputted or not in recep-
tion.
Default: 0 0 (Print inhibited)
SW31 No.7, No.8 Contents of send document are printed 
in memory send
Used to set whether part of send document is printed on the communi-
cation report or not in memory send.
Default: 1 0 (Only the address to which transmission is failed)
SW32 No.1–No.4 Distinctive ringing 
(Australia, New Zealand)
Used to set the ringing pattern as FAX reception.
Default: 0 0 0 0 (OFF)
SW32 No.5 Inhibited to use
SW32 No.6 Index print setup
Used to set whether the index is printed when outputting received doc-
ument or not.
Default: 0 (Not print)
SW32 No.7, No.8 Inhibited to use
SW33 No.1 Page number print setup
Used to set whether the page number is added to the sender informa-
tion print or not.
Default: 1 (Yes)
SW33 No.2–No.7 Inhibited to use
SW33 No.8 Reception data duplex print
Used to set whether duplex print of received data is made or not.
Default: 0 (No)
SW34 No.1, No.2 Flash send wait time (U.K., Netherlands, 
Luxembourg, Belgium, France, Australia, New Zealand: 
Inhibited to use)
Used to set the time from off-hook to Flash send.
Default: 1 0 (1sec)
SW34 No.3, No.4 Inhibited to use
SW34 No.5–No.8 Signal send level Max.
Used to set the max. signal send level.
Default: –8dBm
SW35 No.1 Cover function default setup
Used to set whether cover is added as default or not.
When auto clear is made by pressing C/A key, the machine returns to
this setting.
Default: 0 (No)
SW35 No.2 Answering telephone connection
Used to set whether the functions of answering telephone connection
mode are enabled or not.
Default: 1 (Yes)
SW35 No.3, No.4 CI delete max. OFF time
Used to set the max. wait time between detection of CI signal pulse
(number of times) and detection of the next CI signal pulse.
If CIK signal pulse is not detected within this time, the number of calls
up to that time is cleared.
Default: 0 0 (5sec) (Australia, New Zealand) / 0 1 (10sec) (Europe)
SW35 No.5–No.8 Answering machine call number setting
Used to set the number of calls to switch to auto receive when answer-
ing telephone is not called in when the receive mode is set to the
answering telephone connection mode.
Setting is made in binary input.
Default: 6 times
SW36 No.1–No.8 CNG/mute detection completion time
Used to set the time for completion of CNG signal/mute detection in the
answering telephone connection mode.
Count is made from the last call signal.
Setting is made in binary input.
Default: 45sec
SW37 No.1–No.4 Silence detection start time
Used to set the time between reception of external telephone and
detection of mute in the answering telephone connection mode.
Default: 5sec
SW37 No.5–No.8 Mute judgment time
Used set the mute judgment time when mute is continued for several
seconds.
Default: 5sec
SW38 No.1, No.2 Protocol monitor
Used to set whether communication protocol result is printed or not
after completion of communication.
Default: 0 0 (Not printed.)
SW38 No.3 Protocol monitor save
Used to set whether the protocol monitor of the last communication is
saved or not. When set to "Saved," the previous protocol monitor can
be printed with SIM 66-21.
Default: 1 (Yes)
SW38 No.4 Inhibited to use
AR-FX9  FAX SOFT SWITCH  4 - 26
SW38 No.5, No.6 Flash send time (U.K., Netherlands, 
Luxembourg, Belgium, France, Australia, New Zealand: 
Inhibited to use)
Used to set the Flash send time.
Default: 0 0 (90ms)
SW38 No.7 Transfer function
Used to set whether transfer function is enabled or not.
Default: 1 (Allow)
SW38 No.8 Inhibited to use
SW39 No.1–No.3 Inhibited to use
SW39 No.4–No.8 DTMF signal send time
Used to set DTMF signal send time.
Setting is made in binary input by the increment of 10ms.
Default: 110ms
SW40 No.1–No.8 Number of times of recall in error
Used to set the number of times of recall when a communication error
occurs.
Setting is made in binary input.
When set to 0, recall is not made.
Default: 1 times
SW41 No.1–No.8 Number of times of recall in busy
Used to set the number of times of recall when busy tone is detected
during transmission.
Setting is made in binary input.
When set to 0, recall is not made.
Default: 2 times
SW42 No.1 Inhibited to use
SW42 No.2 FAX receive auto select by CNG detection
Used to set whether FAX receive auto select is enabled or not when
CNG signal is detected with external telephone used.
Default: 1 (Allow)
SW42 No.3 Auto receive select in answering telephone 
connection mode
Used to set whether auto receive select function in answering tele-
phone connection mode is enabled or not.
Default: 0 (Inhibit)
SW42 No.4–No.7 Inhibited to use
SW42 No.8 V.34 mode function in manual communication
Used to set whether V.34 mode is enabled or not in manual communi-
cation.
When, however, SW43-1 is set to "0: OFF," V.34 mode is disabled
even tough this switch is set to "1: ON."
Default: 1 (ON)
SW43 No.1 V.34 mode function
Used to set whether V.34 mode is enabled or not as a capacity of own
machine in send/receive.
Default: 1 (ON)
SW43 No.2 Busy tone detection level table
Used to set the busy tone detection level table.
Default: 0 (constant (ROM))
SW43 No.3 V.34 primary channel return mode
Used to set V.34 primary channel return mode.
Default: 1 (PPh)
SW43 No.4–No.6 Symbol speed mask in V.34 receive
Used to set symbol speed mask in V.34 receive.
Default: 1 0 1 (3429)
SW43 No.7 Silence detection level table
Used to set the mute detection level table.
Default: 0 (constant (ROM))
SW43 No.8 Control channel retrain judgment in V.34 
reception
Used to set control channel retrain judgment in V.34 reception.
Default: 0 (Judge EQM value)
SW44 No.1–No.4 V.34 primary channel send speed
Used to set send start speed in V.34 send.
Setting is made in binary input of N in "2400 (bps) x N" in the range of
2400bps – 33600bps.
N is set in the range of 0 – 15. When set to 0, 2400bps; when set to 15,
33600bps.
When set to 2400bps, all of SW91 No. 1 – 8 must be set as "Disable".
Default: 33600bps
SW44 No.5–No.8 V.34 primary channel receive speed
Used to set receive start speed in V.34 receive.
Setting is made in binary input of N in "2400 (bps) x N" in the range of
2400bps – 33600bps.
N is set in the range of 0 – 15. When set to 0, 2400bps; when set to 15,
33600bps.
When set to 2400bps, all of SW43 No. 4 – 6 must changed to 2400.
Default: 33600bps
SW45 No.1 Inhibited to use
SW45 No.2, No.3 Sequence of year/month/day in LCD, 
report, and sender record
Used to set the sequence of year/month/day in LCD, report, and
sender record.
Default: 1 0 (Day/Month/Year)
SW45 No.4 Time display format
Used to set time display format in LCD, report, and sender record.
Default: 0 (24H)
SW45 No.5–No.8 Scan effective image area main scan 
right edge image loss (SPF)
Used to set image loss of scan effective area.
Image loss on the right edge in SPF main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default:  96 dots
SW46 No.1 Specification of print sequence in duplex print
Used to set the print sequence in duplex print of received data.
When set to 1, an odd-number page is printed after printing the next
even-number page. (214365...)
When set to 0, print is made in the ordinary reception order. (123456...)
Default: 1 (Print order (214365...))
SW46 No.2 Specification of rotating direction duplex back 
surface print
Used to set whether the back surface is rotated 180 degrees in duplex
print or not.
When set to 1, the back surface is rotated 180 degrees and printed.
When set to 0, the back surface is not rotated and printed.
Default: 1 (180 degrees rotation)
AR-FX9  FAX SOFT SWITCH  4 - 27
SW46 No.3 Priority in the day of week
Used to set which is indicated first, day or day of week, when date for-
mat is in the sequence of day, month, and year.
When set to 1, day of week is indicated first, and then day is indicated.
When set to 0, day is indicated first, and then day of week is indicated.
SW46 No.4 Center No. in FAST mode
Used to set which is set as FAST center number, Service-No or Host-
Tel-No.
Default: 0 (Service-No.)
SW46 No.5 Summer time
Used to set whether summer time function is enabled or not.
When set to 1, summer time function is enabled.
When set to 0, summer time function is disabled.
Default: 1 (Allow)
SW46 No.6–No.8 PBX setting (U.K., Netherlands, 
Luxembourg, Belgium, Australia, New Zealand: Inhibited 
to use)
Used to set Connect/Not Connect to PBX and to set the external line
connection method when connected to PBX.
Default: 0 0 0 (Setting OFF)
SW47 No.1 Inhibited to use
SW47 No.2 External telephone connection
Used to set whether external telephone is used or not.
This switch must be set to YES in order to use external telephone.
Default: 1 (Yes)
SW47 No.3–No.8 Inhibited to use
SW48 No.1, No.2 Tone/Pulse default setup
Used to set the dial type.
Default: 1 0 (TONE)
SW48 No.3 Telephone line menu
Used to set whether tone/pulse setting is displayed on the menu or not.
Default: 1 (Inhibit)
SW48 No.4 DP dial pulse number process
Used to set pulse number process in pulse dial.
SW48 No.5–No.8 Scan effective image area main scan left 
edge image loss (SPF)
Used to set image loss of scan effective area.
Image loss on the left edge in SPF main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW49 No.1, No.2 Inhibited to use
SW49 No.3–No.8 Speaker sound volume pattern number 
in DTMF send
Used to set sound volume pattern in DTMF send.
Default: 21
SW50 No.1, No.2 Line monitor volume
Used to set on-hook monitor volume and line volume in FAX communi-
cation.
Default: 1 0 (Medium)
SW50 No.3–No.8 Line monitor volume pattern number
Used to set line monitor volume pattern.
Default: 16
SW51 No.1–No.5 DTMF send level (High group) setup
Used to set high-group send level in DTMF signal send.
Setting is made in binary input in the increment of 1.0dBm.
Default: –6dBm
SW51 No.6 CED detection time
Used to set detection time of CED/ANSam signal for judgment of
detection.
Default: 1000ms
SW51 No.7, No.8 Busy tone detection cycle
Used to set detection cycle of pulses of busy tone for detection of busy
tone.
Default: 0 0 (2puls)
SW52 No.1, No.2 Busy tone detection level
Used to set the mini. Detection level in busy tone detection.
Default: 0 0 (–43dB)
SW52 No.3 Inhibited to use
SW52 No.4 Super G3 disabled in the last call-out of recall 
in case of an error
Used to set whether Super G3 is disabled or not in the last call-out of
recall in case of a send error.
When, however, the number of recall in case of a send error is 0, this
function does not operate.
Default: 0 (Super G3 disabled)
SW52 No.5 Error process in RTN reception
Used to set whether RTN reception is judged as an error or not. (Only
in G3 mode)
When set to 1, RTN reception is not judged as an error.
When set to 0, RTN reception is judged as an error.
Default: 0 (Error)
SW52 No.6, No.7 Inhibited to use
SW52 No.8 V.34 control channel communication speed
Used to set control channel communication speed in V.34 mode.
If the remote machine does not make 2400bps enable, the speed is
always 1200bps.
Default: 0 (1200bps)
SW53 No.1–No.4 Maximum DTMF send level
Used to set the max. send level of DTMF signal.
Setting is made in binary input in the increment of 1.0dBm.
Default: 0dBm
SW53 No.5–No.8 DTMF send level (difference between 
high and low level)
Used to set DTMF signal send level in low group by the difference from
that in high group.
Setting is made in binary input in the increment of 0.5dBm.
Default: +2.0dBm
SW54 No.1–No.4 Scan effective image area sub scan lead 
edge image loss (SPF)
Used to set image loss in scan image area.
Image loss on the lead edge in SPF sub scan direction can be
adjusted. When the set value is increased, image loss on the lead
edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 96 lines
Default: 0 (No) (U.K., Netherlands, Luxembourg, Belgium, 
Australia, New Zealand) / 
1 (Yes) (Germany, Sweden, Spain, Portugal, Italy, 
Switzerland, Finland, Denmark, Norway, France)
Default: 0 (Normal (N)) (Other than New Zealand) / 
1 (10-N) (New Zealand)
AR-FX9  FAX SOFT SWITCH  4 - 28
SW54 No.5–No.8 Scan effective image area sub scan rear 
edge image loss (SPF)
Used to set image loss in scan image area.
Image loss on the rear edge in SPF sub scan direction can be
adjusted. When the set value is increased, image loss on the rear edge
is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW55 No.1–No.7 CI signal OFF detection enable time
Used to set the min. OFF time for judgment of 1 pulse (1 call) of CI
(call-in signal).
If OFF time continues more than the set value, it is judged as 1 pulse.
Setting is made in binary input in the increment of 10ms.
SW55 No.8 Inhibited to use
SW56 No.1–No.3 CI signal ON detection enable time
Used to set the min. ON time for judgment of 1 pulse (1 call) of CI (call-
in signal).
If ON time continues more than the set value, it is judged as 1 pulse.
Setting is made in binary input in the increment of 10ms.
SW56 No.4 Inhibited to use
SW56 No.5, No.6 DT/BT detection frequency range
Used to set DT/BT detection frequency range.
SW56 No.7, No.8 Inhibited to use
SW57 No.1 Inhibited to use
SW57 No.2 Sharp machine mode
Used to set whether communication is made in Sharp machine mode
or not.
Default: 1 (ON)
SW57 No.3 Inhibited to use
SW57 No.4–No.8 Reception gain adjustment
Used to set reception gain correction.
Setting is made in binary input in the increment of 0.5dBm.
Default: 0.0dBm
SW58 No.1–No.4 Dual wait inhibit time after CFR send
Used to set dual wait inhibit time after CFR send.
Setting is made in binary input in the increment of 200ms.
Default: 1600ms
SW58 No.5–No.8 FSK signal settlement time in double 
wait
Used to set FSK signal settlement time in double (dual) wait.
Setting is made in binary input in the increment of 50ms.
Default: 550ms (7)
SW59 No.1, No.2 Inhibited to use
SW59 No.3, No.4 Reception SED ON level
Used to set reception SED ON level.
Default: 1 1 (–48dB)
SW59 No.5, No.6 Transmission cable amplitude equalizer
Used to set transmission cable amplitude equalizer.
Default: 0 0 (0dB)
SW59 No.7, No.8 Reception cable amplitude equalizer
Used to set reception cable amplitude equalizer.
Default: 0 0 (0dB)
SW60 No.1–No.4 Scan effective image area sub scan lead 
edge image loss (SPF back surface)
Used to set image loss in scan image area.
Image loss on the lead edge in SPF bask surface sub scan direction
can be adjusted. When the set value is increased, image loss on the
lead edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 96 lines
SW60 No.5–No.8 Scan effective image area sub scan rear 
edge image loss (SPF back surface)
Used to set image loss in scan image area.
Image loss on the rear edge in SPF bask surface sub scan direction
can be adjusted. When the set value is increased, image loss on the
rear edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW61 No.1–No.8 Inhibited to use
SW62 No.1 Inhibited to use
SW62 No.2 CI signal ON time in V.8 mode
Used to set CI signal ON time in CI signal send in V8 mode.
Default: 0 (9byte (240ms))
SW62 No.3 CI signal OFF time in V.8 mode
Used to set CI signal OFF time in CI signal send in V8 mode.
Default: 0 (1sec)
SW62 No.4, No.5 V.8 mode ANSam signal send time
Used to set ANSam/CED signal send time.
Default: 0 1 (4sec)
SW62 No.6–No.8 Inhibited to use
SW63 No.1, No.2 CI receive number to shift to non-V.34 
communication
Used to set CI receive number to shift to non-V.34 communication.
Default: 1 0 (2 times)
SW63 No.3–No.5 CI send number to shift to non-V.34 
communication
Used to set CI send number to shift to non-V.34 communication.
Setting is made in binary input.
Default: 2
SW63 No.6–No.8 Inhibited to use
SW64 No.1–No.8 Inhibited to use
SW65 No.1–No.8 Inhibited to use
SW66 No.1–No.8 Inhibited to use
SW67 No.1–No.4 Make time (10PPS) setup
Used to set make time in dialing in 10PPS.
Setting is made in binary input in the increment of 1ms.
SW67 No.5–No.8 Inhibited to use
SW68 No.1, No.2 Line open delay time in dial test
Used to set time interval between end of dialing and opening the line.
Valid only in dial test of simulation.
Default: 0 0 (2sec)
SW68 No.3, No.4 Inhibited to use
Default:
1100ms (New Zealand) / 1200ms (Other than New Zealand)
Default:
155ms (Europe) / 195ms (Australia, New Zealand)
Default:
1 1 (245Hz–650Hz) (Europe) / 
1 0 (360Hz–440Hz) (Australia, New Zealand)
Default:
0 0 (0dB) (Europe) / 0 1 (4dB) (Australia, New Zealand)
Default:
32ms (Australia, New Zealand)
33ms (U.K., Netherlands, Luxembourg, Belgium, France) / 
41ms (Germany, Sweden, Spain, Portugal, Italy, 
Switzerland, Finland, Denmark, Norway)