DOWNLOAD Sharp AR-FX9 Service Manual ↓ Size: 1.95 MB | Pages: 72 in PDF or view online for FREE

Model
AR-FX9
Pages
72
Size
1.95 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service manual
File
ar-fx9.pdf
Date

Sharp AR-FX9 Service Manual ▷ View online

AR-FX9  FAX SOFT SWITCH  4 - 21
S
W
104
1
Scan effective image 
area main scan left edge 
image loss (SPF back 
surface)
Binary input
96 dots
0
2
Bit No.
Set range
1
2
3
4
0 to 360 dots
in the interval of 24 dots
1
3
0
4
0
5
Scan effective image 
area main scan right 
edge image loss (SPF 
back surface)
Binary input
96 dots
0
6
Bit No.
Set range
5
6
7
8
0 to 360 dots
in the interval of 24 dots
1
7
0
8
0
S
W
105
1
Scan magnification ratio 
adjustment (OC main 
scan)
1: –
0: +
+
0
2
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0  to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
106
1
Scan magnification ratio 
adjustment (OC sub 
scan)
1: –
0: +
+
0
2
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0  to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
107
1
Scan magnification ratio 
adjustment (SPF back 
surface main scan)
1: –
0: +
+
0
2
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0  to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
108
1
Scan magnification ratio 
adjustment (SPF back 
surface sub scan)
1: –
0: +
+
0
2
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0  to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
109
1
Print magnification ratio 
adjustment (Main scan 
back surface)
1: –
0: +
+
0
2
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0  to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
110
1
Print magnification ratio 
adjustment (Sub scan 
back surface)
1: –
0: +
+
0
2
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0  to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
AR-FX9  FAX SOFT SWITCH  4 - 22
3. Soft switch descriptions
SW1 No.1, No.2 Image quality priority selection
Used to select the image quality setting when pressing C/A key or dur-
ing auto clear.
Default: 0 0 (Normal)
SW1 No.3 Inhibited to use
SW1 No.4 Auto/Manual default setup
Used to select Auto/Manual reception mode when turning on the
power.
Default: 0 (Automatic reception)
SW1 No.5 Send request protection
Used to set enable/disable of the confidential function (inhibit to send
to erroneous destinations) in send request communication (remote
send).
The confidential function is performed by collating the number regis-
tered in this machine and the number registered in the remote
machine.
Sender number 
 Send request allow number
Default: 0 (Protected)
SW1 No.6–No.8 Inhibited to use
SW2 No.1–No.4 Inhibited to use
SW2 No.5–No.8 Remote selection number setup
Used to set the number in binary input for remote switch receive from
external telephone.
However, "
" in the remote switch number (X
∗∗
) is fixed.
Default: 5
SW3 No.1–No.5 Density default setup
Used to set the density when pressing C/A key or during auto clear.
Default: 0 0 1 0 0 (Medium)
SW3 No.6 Inhibited to use
SW3 No.7, No.8 Size specification
Used to set the size specification (AB series, inch series).
Under setting of "Follow information from machine," when command
information from the machine is uncertain, set this item to AB series.
Default: 0 1 (Conforms to the machine information.)
SW4 No.1–No.4 Recall interval in communication error
Used to set the interval for recall when communication is cut off by an
error during memory send. (Including no response from the remote
machine.)
Setting is made in binary input.
When set to 0, resend is mad immediately after completion of commu-
nication.
However, the time interval set by SW21 "Interval between completion
of communication and the next call" is valid.
Default: 1min
SW4 No.5–No.8 Recall interval in busy
Used to set the interval for the next call when busy tone is detected in
communication.
Setting is made in binary input.
Default: 3min
SW5 No.1, No2 Inhibited to use
SW5 No.3, No.4 G3 send data accumulation wait time
Used to set wait time for accumulation of image data before sending
image data directly.
Default: 0 0 (6sec)
SW5 No.5–No.8 Pause time setup
Used to set pause time when registering dials.
Default: 2sec
SW6 No.1 ECM
Used to set YES/NO of error resend mode.
When, however, SW43-1 (V.34 mode function) is OFF or when SW34-
1 (V.34 mode function) is ON and send is made other than SG3, ECM
setting of "NO" is valid.
Since the ECM function is essential in V.34 mode and the remote
machine may perform checking, when SW43-1 (V.34 mode function) is
ON , this function is invalid in reception.
Default: 1 (Yes)
SW6 No.2 CED signal send
Used to set YES/NO of CED signal send.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
Default: 1 (Yes)
SW6 No.3 CSI transmission
Used to set YES/NO of CSI signal send.
CSI signal includes the sender's number.
Default: 1 (Yes)
SW6 No.4 DIS reception confirmation in G3 send
Used to set YES/NO of DIS receive check in G3 mode send.
When set to 1, DIS receive twice is checked.
When set to 0, DIS once is checked when "NSF/DIS" is received; and
DIS twice is checked when NSF is not received.
Default: 0 (Once in NFS reception, 2 time in DIS reception)
SW6 No.5 Inhibited to use
SW6 No.6 EOL detection timer
Used to set detection timer of EOL (EndOfLine) in Phase C receive.
Default: 0 (13sec)
SW6 No.7 Countermeasure for echo in reception (CED 
tone send interval)
Used to set the interval from CED send to FSK signal send of DIS.
Default: 0 (75ms)
SW6 No.8 Countermeasure for echo in transmission (After 
reception of DIS, hold time up to signal send is set.)
Used to set the interval from DIS receive to DSC signal send.
Default: 0 (200ms)
SW7 No.1 Inhibited to use
SW7 No.2 Dial tone detection
Used to set whether dial tone is detected or not when calling out.
When set to 1, dial tone is detected before calling out.
When set to 0, dial tone is not detected and dialing is made after a cer-
tain time (3.5sec).
Default: 0 (No)
SW7 No.3 Busy tone detection
Used to set YES/NO of busy tone detection when calling out.
Default: 1 (Yes)
SW7 No.4 Dial tone monitoring time
Used to set the monitoring time when detecting dial tone.
Default: 0 (5sec)
SW7 No.5 Inhibited to use
SW7 No.6 Max. length of reception
Used to set max. length of reception for long document.
Default: 0 (1.5m)
AR-FX9  FAX SOFT SWITCH  4 - 23
SW7 No.7, No.8 Destination display time when one-touch 
key is pressed
Used to set the time from displaying the destination to the next opera-
tion in one-touch dial or reduction dial.
Default: 0 0 (2sec)
SW8 No.1 Memory transmission/direct transmission 
default setup
Used to set whether memory send is ON or direct send is made (OFF)
in the memory mode when pressing C/A key or auto clear.
Default: 0 (Memory transmission)
SW8 No.2 Proxy reception
Used to set whether proxy reception is enabled or not.
When set to 0, under the following error status, auto receive is not
made in auto receive mode.
• Cover open
• Unit error (Toner, drum, developing-related errors)
• Recording paper JAM
• Document JAM
• Recording paper empty
When set to 1, proxy reception is allowed.
Default: 1 (Yes)
SW8 No.3 Inhibited to use
SW8 No.4 Quick online send
Used to set whether quick online send function is enabled or not.
When set to 0, send in memory mode ON is made in memory send.
When set to 1, send in memory mode ON is made in quick online send.
Default: 1 (Yes)
SW8 No.5 Remote select function
Used to set whether remote select function is enabled or not.
Default: 1 (Yes)
SW8 No.6–No.8 Number of times of CNG detection
Used to set the number of times of CNG detection for judgment of
detection.
Default: 3 times
SW9 No.1 Print of total communication time and total 
pages
Used to set whether the total communication time and total pages are
printed on the communication report or not.
When set to 1, the total communication time and total pages are
printed on the communication report.
When set to 0, the total communication time and total pages are not
printed on the communication report.
Default: 1 (Yes)
SW9 No.2 Inhibited to use
SW9 No.3–No.8 Ringing volume pattern number
Used to set ringing volume pattern.
Default: 1
SW10 No.1 Measurement of communication time (image)
Used to set YES/NO of measurement of communication time in phase
C. It is the communication time in the latest phase C. (Unit: msec)
Valid only in ECM communication.
Default: 1 (Yes)
SW10 No.2 Sender's telephone number registration
Used to set whether registered sender's telephone number can be
changed or not.
Default: 0 (Allow)
SW10 No.3–No.5 Inhibited to use
SW10 No.6 ECM byte/frame
Used to set the frame size of error correction mode to be notified to the
remote machine.
Default: 0 (256 [bytes/frame])
SW10 No.7, No.8 Inhibited to use
SW11 No.1–No.8 Scanner resource holding time out in 
direct send
Used to set time-out time to hold scanner resource in direct send.
Default: 26sec
SW12 No.1–No.4 Call time setup in automatic 
transmission (T0 timer setup)
Used to set call time in automatic send.
Setting is made by binary input of N into "(5sec x N) + 30sec" in the
increment of 5sec.
Default: 45sec
SW12 No.5 Inhibited to use
SW12 No.6, No.7 CI detection
Used to set the detection frequency of CI signal (call signal).
Default: 0 0 (4 sine wave)
SW12 No.8 Inhibited to use
SW13 No.1, No.2 Inhibited to use
SW13 No.3, No.4 Ringing volume
Used to set the ringing volume when call-in.
Default: 1 0 (Medium)
SW13 No.5, No.6 Speaker volume in DTMF send
Used to set the volume of transmission and DTMF sound from the
speaker when SPEAKER key is pressed.
Default: 1 0 (Medium)
SW13 No.7, No.8 Inhibited to use
SW14 No.1–No.8 Inhibited to use
SW15 No.1 Busy tone detection time (Lower limit)
Used to set the lower limit of busy tone detection time (ON time).
Default: 0 (250ms)
SW15 No.2 Busy tone detection time (Upper limit)
Used to set the upper limit of busy tone detection time (ON time).
SW15 No.3 Busy tone detection time (Lower limit 2)
Used to set the lower limit 2 of busy tone detection time (ON time).
SW15 No.4–No.8 Signal send level
Used to set signal send level from MODEM.
Setting is made in binary input in the increment of 1dBm.
Default: –11dBm
SW16 No.1–No.4 Modem speed (V.33 mode or less)
Used to set send start speed in communication other than V.34 mode.
In an area of poor communication conditions, it is recommended to set
communication speed to a lower level in advance.
Default: 1 0 0 0 (V.17 14.4kbps)
SW16 No.5, No.6 Modem speed in reception fixed
Used to set receive procedure start speed in a remote machine other
than V.34.
In setting of no fixing, the operations are the same as V.17-14400BPS.
Default: 0 0 (No fixing)
SW16 No.7, No.8 Inhibited to use
SW17 No.1 Inhibited to use
Default: 0 (750ms) (Europe) / 1 (650ms) (Australia, New Zealand)
Default: 0 (Follows SW15-1.) (Europe) / 
1 (150ms) (Australia, New Zealand)
AR-FX9  FAX SOFT SWITCH  4 - 24
SW17 No.2 MH fixed (Except for SG3)
Used to set whether coding capacity is fixed to MH or not in communi-
cation other than SG3.
Default: 0 (No)
SW17 No.3 ECM MMR mode (Except for SG3)
Used to set whether MMR coding capacity is allowed or not in commu-
nication other than SG3.
Default: 1 (Yes)
SW17 No.4 ECM JBIG mode (Except for SG3)
Used to set whether JBIG coding capacity is allowed or not in commu-
nication other than SG3.
Default: 1 (Yes)
SW17 No.5 Inhibited to use
SW17 No.6 MH fixed (in SG3)
Used to set whether coding capacity is fixed to MH or not in SG3 com-
munication.
Default: 0 (No)
SW17 No.7 ECM MMR mode (in SG3)
Used to set whether MMR coding capacity is allowed or not in SG3
communication.
Default: 1 (Yes)
SW17 No.8 ECM JBIG mode (in SG3)
Used to set whether JBIG coding capacity is allowed or not in SG3
communication.
Default: 1 (Yes)
SW18 No.1–No.8 Inhibited to use
SW19 No.1–No.5 Inhibited to use
SW19 No.6 Recording table automatic print
Used to set whether communication report is automatically outputted
or not when the number of send/receive items which have not output-
ted yet on communication report reaches 50.
When set to 1, they are automatically outputted.
When set to 0, they are not outputted even the number of items
reaches 50.
Default: 0 (No)
SW19 No.7, No.8 Inhibited to use
SW20 No.1, No.2 Line sound monitor range
Used to set line sound monitor range when line sound monitor function
is used.
Default: 0 0 (OFF)
SW20 No.3 Line monitor display
Used to set whether the communication speed and the receive level
are displayed on LCD or not.
Default: 0 (No)
SW20 No.4 Inhibited to use
SW20 No.5 Receivable memory capacity
Used to set the remained memory capacity for allowing call-in.
Default: 0 (128Kbyte)
SW20 No.6–No.8 Inhibited to use
SW21 No.1–No.8 Interval between completion of 
communication and the next call
Used to set the interval between completion of communication and the
next call.
Setting is made in binary input.
Default: 6sec
SW22 No.1–No.8 Inhibited to use
SW23 No.1–No.8 Inhibited to use
SW24 No.1, No.2 Inhibited to use
SW24 No.3, No4 Specified number reception (ANTI JUNK 
FAX)
Used to set whether the FAX receive rejection function is made valid or
not for registered FAX numbers.
Default: 0 0 (Not set.)
SW24 No.5 Inhibited to use
SW24 No.6 Document output setup in reception
Used to set the document output procedure; whether all the received
documents are collectively outputted after completion of reception or
every page is outputted when it is received.
Default: 1 (Collective output after completion of reception)
SW24 No.7 Inhibited to use
SW24 No.8 Automatic reduction print
Used to set whether automatic reduction print is performed or not so
that a document longer than the fixed size and smaller than the auto-
matic reduction line number setting is printed on fixed size paper.
Default: 1 (Allow)
SW25 No.1–No.4 Automatic reduction rate setup
Used to set automatic reduction rate when automatic reduction print is
valid.
Default: 10%
SW25 No.5, No.6 Transmission end sound tone
Used to set transmission end sound tone in transmission.
Default: 0 1 (1000Hz)
SW25 No.7, No.8 Reception end sound tone
Used to set reception end sound tone in reception.
Default: 0 1 (1000Hz)
SW26 No.1 Read completion sound
Used to set whether buzzer sound is made or not when scan is com-
pleted.
In manual send or when scan is completed in direct send, buzzer
sound is not made.
Default: 0 (1sec)
SW26 No.2 Inhibited to use
SW26 No.3, No.4 Speaker volume setup
Used to set speaker volume.
The following sounds are the targets of this setting.
• Alarm sound
• Send end sound
• Receive end sound
• Scan end sound
Default: 0 1 (Small)
SW26 No.5–No.8 Inhibited to use
SW27 No.1–No.6 Inhibited to use
SW27 No.7, No.8 Recording paper tray selection
Used to select the recording paper tray used by FAX.
Valid only when two cassettes are installed.
Default: 0 0 (AUTO)
SW28 No.1–No.8 Inhibited to use
SW29 No.1–No.4 Number of auto switch calls of manual 
reception 
 auto reception
Used to set the number of calls to switch to auto receive in manual
receive mode.
When set to 0, switch to auto receive is not made.
Default: 0 time
Page of 72
Display