AR-FX9  FAX SOFT SWITCH  4 - 29
SW68 No.5–No.8 T1 timer setup
Used to set time for connection of the line when the remote machine
does not respond in FAX communication.
The time of ITU-T standard is 35 ± 5sec.
Setting is made in binary input in the increment of 5sec.
Default: 40sec
SW69 No.1–No.8 Inhibited to use
SW70 No.1–No.3 Inhibited to use
SW70 No.4 Reception waiting time between frames
Used to set reception wait time between frames.
Default: 0 (3.4sec)
SW70 No.5, No.6 Preamble send time of 300bps
Used to set preamble send time of 300bps.
Default: 0 1 (1.0sec)
SW70 No.7, No.8 RCP send times
Used to set number of times of RCP frame send.
Default: 0 0 (3 times)
SW71 No.1–No.8 Inhibited to use
SW72 No.1 EYE-Q check
Used to set TCF check in TCF reception.
When set to 1, check is made only with EYE-Q value (EQM value).
Therefore, TCF check is loosely made. 
When set to 0, check is made with received data and EYE-Q value
(EQM value).
Default: 0 (0 reception & EYE-Q check)
SW72 No.2 ERR frame reception operation
Used to set operations when an image with an error frame is received.
Default: 0 (Not continue process. (Error))
SW72 No.3, No.4 Waiting time for CED/ANSam send start
Used to set waiting time from when the line is connected and the
machine enters FAX receive state to when CED/ANSam signal is send
to the line.
Default: 0 0 (2.25sec)
SW72 No.5 RTC EOL send times
Used to set number of times of RTC EOL send.
Default: 1 (6 times)
SW72 No.6 Inhibited to use
SW72 No.7, No.8 CNG send start
Used to set CNG send time.
Default: 0 0 (0.5sec)
SW73 No.1, No.2 Minimum flags between frames
Used to set minimum flag number between frames.
Default: 0 0 (2-flag)
SW73 No.3, No.4 Phase C head dummy data send time
Used to set phase C head dummy data send time.
Default: 0 0 (0.2sec)
SW73 No.5, No.6 Inhibited to use
SW73 No.7, No.8 Flag-adrs timer setup (V.21-FSK)
Used to set timer between Flag-adrs in FSK signal receive in commu-
nication other than  V.34 mode.
FSK signal receive in V.34 mode does not conform to this soft switch.
Default: 0 0 (6sec)
SW74 No.1–No.4 Print effective image area sub scan lead 
edge void
Used to set print image area void.
The void amount on the lead edge in the sub scan direction can be
adjusted. When the set value is increased, the void amount on the lead
edge is increased. 
Setting is made in binary input in the increment of 16 lines.
Default: 32 lines
SW74 No.5–No.8 Inhibited to use
SW75 No.1, No.2 Inhibited to use
SW75 No.3, No.4 Communication end sound (Buzzer 
sound length) setting
Used to set the length of communication end buzzer sound in commu-
nication.
Default: 0 0 (3sec)
SW75 No.5–No.8 Print effective image area main scan 
void
Used to set void amount in print image area.
The void amount in the main scan direction can be adjusted. When the
set value is increased, the margins on the right and the left are
increased.
Setting is made in binary input in the increment of 16 dots.
Default: 48 dots
SW76 No.1–No.8 Scan magnification ratio adjustment 
(SPF main scan)
Used to set main scan magnification ratio in SPF scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW77 No.1–No.8 Scan magnification ratio adjustment 
(SPF sub scan)
Used to set sub scan magnification ratio in SPF scan. 
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW78 No.1–No.8 Print magnification ration adjustment 
(main scan)
Used to set main scan magnification ratio in print. 
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW79 No.1–No.8 Print magnification ration adjustment 
(sub scan)
Used to set sub scan magnification ratio in print. 
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW80 No.1–No.8 Destination information
Used to set country code.
SW81 No.1–No.8 Language information
Used to set language.
SW82 No.1–No.4 OC scan size default setting
Used to set OC scan default size.
Default: 0 0 1 1 (A4)
SW82 No.5–No.8 Inhibited to use
SW83 No.1, No.2 Inhibited to use
SW83 No.3–No.8 Speaker sound volume setting pattern 
number
Used to set sound volume pattern of communication end and scan
end.
Default: 1
SW84 No.1–No.8 Inhibited to use
AR-FX9  FAX SOFT SWITCH  4 - 30
SW85 No.1–No.8 Inhibited to use
SW86 No.1–No.8 Inhibited to use
SW87 No.1–No.8 Inhibited to use
SW88 No.1–No.8 Inhibited to use
SW89 No.1–No.8 Inhibited to use
SW90 No.1–No.8 Inhibited to use
SW91 No.1 Symbol speed 3429 send enable in V.34 send
Used to set whether symbol speed of 3429Hz is allowed or not in V.34
send.
Default: 1 (Enable)
SW91 No.2 Symbol speed 3200 high carrier send enable in 
V.34 send
Used to set whether use of high carrier is allowed or not when symbol
speed of 3200Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.3 Symbol speed 3200 low carrier send enable in 
V.34 send
Used to set whether use of low carrier is allowed or not when symbol
speed of 3200Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.4 Symbol speed 3000 high carrier send enable in 
V.34 send
Used to set whether use of high carrier is allowed or not when symbol
speed of 3000Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.5 Symbol speed 3000 low carrier send enable in 
V.34 send
Used to set whether use of low carrier is allowed or not when symbol
speed of 3000Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.6 Symbol speed 3429 enable in V.34 send
Used to set whether use of 3429Hz is allowed or not as symbol speed
in V.34 send.
Default: 1 (Enable)
SW91 No.7 Symbol speed 2800 enable in V.34 send
Used to set whether use of 2800Hz is allowed or not as symbol speed
in V.34 send.
Default: 1 (Enable)
SW91 No.8 Symbol speed 2743 enable in V.34 send
Used to set whether use of 2743Hz is allowed or not as symbol speed
in V.34 send.
Default: 1 (Enable)
SW92 No.1–No.8 Inhibited to use
SW93 No.1–No.8 Inhibited to use
SW94 No.1–No.8 Inhibited to use
SW95 No.1–No.8 Inhibited to use
SW96 No.1–No.8 Inhibited to use
SW97 No.1–No.8 Inhibited to use
SW98 No.1–No.8 Inhibited to use
SW99 No.1–No.8 Inhibited to use
SW100 No.1–No.8 Inhibited to use
SW101 No.1–No.4 Print effective image area sub scan 
lead edge void (Back surface)
Used to set void amount in print image area.
Void amount on the lead edge in sub scan direction can be adjusted.
When the set value is increased, the margin on the lead edge is
increased.
Setting is made in binary input in the increment of 16 lines.
Default: 32 lines
SW101 No.5–No.8 Print effective image area sub scan rear 
edge void (Back surface)
Void amount on the rear edge in sub scan direction can be adjusted.
When the set value is increased, the margin on the read edge is
increased.
Setting is made in binary input in the increment of 16 lines.
Default: 48 lines
SW102 No.1–No.4 Scan effective image area main scan 
left edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the left edge in OC main scan direction can be adjusted.
When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW102 No.5–No.8 Scan effective image area main scan 
right edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the right edge in OC main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW103 No.1–No.4 Scan effective image area sub scan 
lead edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the lead edge in OC sub scan direction can be adjusted.
When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 96 lines
SW103 No.5–No.8 Scan effective image area sub scan 
rear edge image loss (OC)
Used to set image loss in scan image area. 
Image loss on the rear edge in OC sub scan direction can be adjusted.
When the set value is increased, image loss is increased. 
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW104 No.1–No.4 Scan effective image area main scan 
left edge image loss (SPF back surface)
Used to set image loss in scan image area.
Image loss in SPF back surface main scan direction can be adjusted.
When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW104 No.5–No.8 Scan effective image area main scan 
right edge image loss (SPF back surface)
Used to set image loss in scan image area.
Image loss on the right edge in SPF back surface main scan direction
can be adjusted. When the set value is increased, image loss is
increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
AR-FX9  FAX SOFT SWITCH  4 - 31
SW105 No.1–No.8 Scan magnification ratio adjustment 
(OC main scan)
Used to set the main san magnification ratio in OC main scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW106 No.1–No.8 Scan magnification ratio adjustment 
(OC sub scan)
Used to set the sub scan magnification ratio in OC sub scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW107 No.1–No.8 Scan magnification ratio adjustment 
(SPF back surface main scan)
Used to set the main scan magnification ratio in SPF back surface
scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW108 No.1–No.8 Scan magnification ratio adjustment 
(SPF back surface sub scan)
Used to set the sub scan magnification ratio in SPF back surface scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW109 No.1–No.8 Print magnification ratio adjustment 
(Main scan back surface)
Used to set the main scan magnification ratio in back surface print.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW110 No.1–No.8 Print magnification ratio adjustment 
(Sub scan back surface)
Used to set the sub scan magnification ratio in back surface print.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
AR-FX9  TROUBLE CODES  5 - 1
[5] TROUBLE CODES
1. Trouble codes
A. Trouble codes list
B. Details of trouble codes
2. Communication error codes
A. Error code identification
Communication error xx (xxxx)
(In print out, the communication error display is made. In FAX status
check, “NGxxxxxx” is displayed.
When transmission or reception is not executed normally due to distur-
bance in protocol signals and image signals by the trouble in the line,
the code of 6 digits is displayed on the transmission result check menu
(reception result check menu).
Upper 2 digits of a communication error code: 00 – 58 (error code) is
displayed. (Communication result code)
Lower 4 digits of a communication error code: Error code1, Error code
2
1) Refer to the communication result code.
2) Refer to error code 1.
3) Refer to error code 2.
(Error code 1 other than V.34 mode is “00”.)
<Communication result code>
Main 
code
Sub 
code
Details of trouble
F6
10
FAX board trouble
U1
03
FAX board battery error
Main 
code
Sub 
code
Details of trouble
F6
10
Content FAX board trouble
Detail
Communication trouble between MCU and FAX 
control PWB
Cause
FAX control PWB connector disconnection
Defective harness between FAX control PWB 
and MCU PWB
Motherboard connector pin breakage
FAX control PWB ROM error/Data error
IC on FAX PWB causes abnormality
Check 
and 
remedy
Check connector/harness of FAX control PWB 
and MCU PWB.
Check the grounding of the copier.
Check FAX control PWB ROM.
Replace the FAX PWB.
U1
03
Content FAX board battery error
Details
The SRAM backup battery voltage on FAX 
PWB falls.
Cause
The SRAM backup battery voltage on FAX 
PWB falls.
Check 
and 
remedy
Check voltage of the SRAM back up battery.
Replace the battery.
Error code 
(Communication 
result)
Communication 
report result 
column
Communication interruption 
content
0 – 31
For details of 0 – 
31, refer to the 
communication 
result code.
Depends on the 
communication 
disconnection position.
For 16 or later, V.34 mode 
communication.
33
Busy
The calling side cannot 
connect the line with the 
other party.
34
Cancel
An interruption command is 
made during transmission or 
reception.
A reservation is canceled.
An interruption command is 
entered with the interruption 
key.
35
Power OFF
Power OFF during 
transmission or reception
36
(Recording paper 
empty)
37
(Recording paper 
jam)
38
Reception 
memory over
Memory over during 
reception
39
(Discrepancy in 
the number of 
sheets)
40
(Interface not 
accepted)
41
Transmission 
length over
The length of transmission 
data of one page exceeds 
the range during 
transmission.
42
Reception length 
over
The length of reception data 
of one page exceeds the 
range during reception.
43
Communication 
(OK)
Communication enable 
before transmission
44
Document error
A document jam during 
direct transmission
45
(Image quality 
error)
46
No response from 
the other party
The FAX signal from the 
other party cannot detect 
within T1 time.
47
(Communication 
error)
48
OK
Communication normal end
49
No send request 
function on the 
other party
The other party has no send 
request function when 
receiving a send request.
The other party has no data 
to send.
50
Send request not 
accepted
DCN is received for DTC 
when sending a send 
request.
There is no data to send 
when sending a send 
request.
51
Send request 
enable number 
discrepancy
Discrepancy in the enable 
number when sending a 
send request.
Discrepancy in the system 
number when sending a 
send request.
52
No confidential 
function on the 
other party
The other party has no 
confidential function when 
sending a confidential 
message. (Including the 
other company’s machines)
Error code 
(Communication 
result)
Communication 
report result 
column
Communication interruption 
content
Page of 72
Display

Click on the first or last page to see other AR-FX9 service manuals if exist.