DOWNLOAD Sharp AR-FX9 Service Manual ↓ Size: 1.95 MB | Pages: 72 in PDF or view online for FREE

Model
AR-FX9
Pages
72
Size
1.95 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service manual
File
ar-fx9.pdf
Date

Sharp AR-FX9 Service Manual ▷ View online

AR-FX9  FAX SOFT SWITCH  4 - 5
: A = U.K., Netherlands, Luxembourg, Belgium / B = Germany, Sweden, Spain, Portugal, Italy, Switzerland, Finland, Denmark, Norway / C = France / D = Australia / E = New Zealand
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
A B C D E
S
W
15
1
Busy tone detection 
time (Lower limit)
1: 350ms
0: 250ms
250ms
0 0 0 0 0
2
Busy tone detection 
time (Upper limit)
1: 650ms
0: 750ms
750ms (A, B, C)
650ms (D, E)
0 0 0 1 1
3
Busy tone detection 
time (Lower limit 2)
1: 150ms
0: Follows SW15-1.
Follows SW15-1. 
(A, B, C)
150ms (D, E)
0 0 0 1 1
4
Signal send level
Binary input
–11dBm
0 0 0 0 0 When a value 
outside the set 
range is set, the 
initial value is set.
5
Bit No.
Set range
4
5
6
7
8
0 (0dBm) to 26 (–26dBm)
1 1 1 1 1
6
0 0 0 0 0
7
1 1 1 1 1
8
1 1 1 1 1
S
W
16
1
Modem speed 
(V.33 mode or less)
Bit  No.
1
2
3
4
V.17 14.4kbps
1 1 1 1 1
V.27 2400bps
0
0
0
0
V.29 9600bps
0
0
0
1
2
V.27 4800bps
0
0
1
0
0 0 0 0 0
V.29 7200bps
0
0
1
1
V.33 14.4kbps
0
1
0
0
3
V.33 12.0kbps
0
1
1
0
0 0 0 0 0
V.17 9600bps
1
0
0
1
V.17 12.0kbps
1
0
1
0
4
V.17 7200bps
1
0
1
1
0 0 0 0 0
V.17 14.4kbps
Others
5
Modem speed in 
reception fixed
Bit No.
5
6
No fixing
0 0 0 0 0
No fixing
0
0
V.29-9600BPS
0
1
6
V.27ter-4800BPS
1
0
0 0 0 0 0
V.17-14400BPS
1
1
7
Inhibited to use
0 0 0 0 0
8
0 0 0 0 0
S
W
17
1
Inhibited to use
0 0 0 0 0
2
MH fixed (Except for 
SG3)
1: Yes
0: No (depending on the 
other party’s machine)
No
0 0 0 0 0
3
ECM MMR mode 
(Except for SG3)
1: Yes
0: No
Yes
1 1 1 1 1
4
ECM JBIG mode 
(Except for SG3)
1: Yes
0: No
Yes
1 1 1 1 1
5
Inhibited to use
0 0 0 0 0
6
MH fixed (in SG3)
1: Yes
0: No (depending on the 
other party’s machine)
No
0 0 0 0 0
7
ECM MMR mode (in 
SG3)
1: Yes
0: No
Yes
1 1 1 1 1
8
ECM JBIG mode (in 
SG3)
1: Yes
0: No
Yes
1 1 1 1 1
S
W
18
1
Inhibited to use
1 1 1 1 1
2
1 1 1 1 1
3
0 0 0 0 0
4
1 1 1 1 1
5
0 0 0 0 0
6
0 0 0 0 0
7
0 0 0 0 0
8
0 0 0 0 0
S
W
19
1
Inhibited to use
0 0 0 0 0
2
1 1 1 1 1
3
0 0 0 0 0
4
0 0 0 0 0
5
0 0 0 0 0
6
Recording table 
automatic print
1: Yes
0: No
No
0 0 0 0 0
Refer to User 
program “AUTO 
LISTING”.
7
Inhibited to use
0 0 0 0 0
8
0 0 0 0 0
AR-FX9  FAX SOFT SWITCH  4 - 6
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
S
W
20
1
Line sound monitor 
range
Bit No.
1
2
OFF
0
When a value outside 
the set range is set, the 
initial value is set.
OFF
0
0
Up to NSF signal send/
receive
0
1
2
All
1
0
0
1
1
3
Line monitor display
1: Yes
0: No
No
0
4
Inhibited to use
0
5
Receivable memory 
capacity
1: 64Kbyte
0: 128Kbyte
128Kbyte
0
6
Inhibited to use
0
7
0
8
0
S
W
21
1
Interval between 
completion of 
communication and the 
next call
Binary input
6sec
0
2
Bit No.
Set range
1
2
3
4
5
6
7
8
0 to 255sec
0
3
0
4
0
5
0
6
1
7
1
8
0
S
W
22
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
23
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
24
1
Inhibited to use
0
2
0
3
Specified number 
reception (ANTI JUNK 
FAX)
Bit No.
3
4
Not set.
0
Refer to Main menu 
“ANTI JUNK FAX”.
When a value outside 
the set range is set, the 
initial value is set.
Not set.
0
0
4
Receive inhibit
0
1
0
5
Inhibited to use
0
6
Document output setup 
in reception
1: Collective output after 
completion of reception
0: Output after reception of 
every page
Collective output after 
completion of reception
1
7
Inhibited to use
0
8
Automatic reduction 
print
1: Allow
0: Inhibit
Allow
1
Refer to User program 
“AUTO RCV 
REDUCE”.
S
W
25
1
Automatic reduction 
rate setup
Binary input
10%
1
2
Bit No.
Set range
1
2
3
4
0 to 15%
0
3
1
4
0
5
Transmission end 
sound tone
Bit No.
5
6
1000Hz
0
When a value outside 
the set range is set, the 
initial value is set.
550Hz
0
0
6
1000Hz
0
1
1
1700Hz
1
0
7
Reception end sound 
tone
Bit No.
7
8
1000Hz
0
When a value outside 
the set range is set, the 
initial value is set.
550Hz
0
0
8
1000Hz
0
1
1
1700Hz
1
0
AR-FX9  FAX SOFT SWITCH  4 - 7
S
W
26
1
Read completion sound 1: Mute
0: 1sec
1sec
0
2
Inhibited to use
0
3
Speaker volume setup
Bit No.
3
4
Small
0
Refer to User program 
“BEEPER VOLUME 
(send completion 
sound / receive 
completion sound / 
scan completion sound 
/ alarm sound)”
Silent
0
0
Small
0
1
4
Medium
1
0
1
Large
1
1
5
Inhibited to use
0
6
0
7
0
8
0
S
W
27
1
Inhibited to use
0
2
1
3
1
4
1
5
1
6
0
7
Recording paper tray 
selection
Bit No.
7
8
AUTO
0
Refer to User program 
“TRAY SELECTION”.
When a value outside 
the set range is set, the 
initial value is set.
AUTO
0
0
TRAY1
0
1
8
TRAY2
1
0
0
1
1
S
W
28
1
Inhibited to use
1
2
1
3
0
4
1
5
0
6
0
7
0
8
0
S
W
29
1
Number of auto switch 
calls of manual 
reception 
 auto 
reception
Binary input
0 time
0 Refer to User program 
“# OF RINGS MANUAL 
RX”.
When a value outside 
the set range is set, the 
initial value is set.
2
Bit No.
Set range
1
2
3
4
0 to 9
Not switched when 0.
0
3
0
4
0
5
Setup of number of 
times of call rings
Binary input
2 times
0 Refer to User program 
“# OF RINGS AUTO 
RX”.
When a value outside 
the set range is set, the 
initial value is set.
6
Bit No.
Set range
5
6
7
8
0 to 9 times
0
7
1
8
0
S
W
30
1
Report output when 
canceling
1: Output
0: Not output
Not output
0
2
Inhibited to use
0
3
1
4
0
5
Default data, sender 
print
1: ON
0: OFF
ON
1
6
Inhibited to use
0
7
Date/sender print 
position setup
1: Inside of document
0: Outside of document
Outside of document
0
8
Inhibited to use
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
AR-FX9  FAX SOFT SWITCH  4 - 8
: A = U.K., Netherlands, Luxembourg, Belgium / B = Germany, Sweden, Spain, Portugal, Italy, Switzerland, Finland, Denmark, Norway / C = France / D = Australia / E = New Zealand
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
A B C D E
S
W
31
1
Report output 
(in transmission)
Bit No.
1
2
Only when 
transmission is 
failed.
1 1 1 1 1
Refer to User 
program “PRINT 
SELECTION”.
When a value outside 
the set range is set, 
the initial value is set.
Print inhibited
0
0
All print
0
1
2
Only  when 
transmission is failed.
1
0
0 0 0 0 0
1
1
3
Report output 
(In broadcast and 
sequential send 
request)
Bit No.
3
4
All print
0 0 0 0 0
Refer to User 
program “PRINT 
SELECTION”.
When a value 
outside the set 
range is set, the 
initial value is set.
Print inhibited
0
0
All print
0
1
4
Only the address to 
which transmission is 
failed
1
0
1 1 1 1 1
1
1
5
Report output 
(in reception)
Bit No.
5
6
Print inhibited
0 0 0 0 0
Refer to User 
program “PRINT 
SELECTION”.
When a value 
outside the set 
range is set, the 
initial value is set.
Print inhibited
0
0
All print
0
1
6
Only in error
1
0
0 0 0 0 0
1
1
7
Contents of send 
document are printed in 
memory send
Bit No.
7
8
Only the address 
to which 
transmission is 
failed
1 1 1 1 1
Refer to User 
program “PRINT 
SELECTION”.
When a value 
outside the set 
range is set, the 
initial value is set.
Print inhibited
0
0
All print
0
1
8
Only the address to 
which transmission is 
failed
1
0
0 0 0 0 0
1
1
S
W
32
1
Distinctive ringing 
(Australia, New 
Zealand)
Bit No.
1
2
3
4
OFF
0 0 0 0 0 Refer to User 
program 
“DISTINCTIVE 
RING”.
When a value outside 
the set range is set, 
the initial value is set.
2
OFF
0
0
0
0
0 0 0 0 0
Standard/ON
0
0
0
1
3
0 0 0 0 0
4
0 0 0 0 0
5
Inhibited to use
0 0 0 0 0
6
Index print setup
1: Print
0: Not print
Not print
0 0 0 0 0
Refer to User 
program “INDEX 
PRINT”.
7
Inhibited to use
0 1 1 0 0
8
0 0 0 0 0
S
W
33
1
Page number print 
setup
1: Yes
0: No
Yes
1 1 1 1 1
2
Inhibited to use
0 0 0 0 0
3
0 0 0 0 0
4
0 0 0 0 0
5
0 0 0 0 0
6
0 0 0 0 0
7
0 0 0 0 0
8
Reception data duplex 
print
1: Yes
0: No
No
0 0 0 0 0
Refer to User 
program “DUPLEX 
RCV”.
S
W
34
1
Flash send wait time 
(U.K., Netherlands, 
Luxembourg, Belgium, 
France, Australia, New 
Zealand: Inhibited to 
use)
Bit No.
1
2
1sec
0 1 0 0 0
0sec
0
0
0.5sec
0
1
2
1sec
1
0
0 0 0 0 0
2sec
1
1
3
Inhibited to use
0 0 0 0 0
4
0 0 0 0 0
5
Signal send level Max.
Binary input
–8dBm
1 1 1 1 1
6
Bit No.
Set range
5
6
7
8
0 (0dBm) to 15 (–15dBm)
0 0 0 0 0
7
0 0 0 0 0
8
0 0 0 0 0
Page of 72
Display