Sharp AR-FX10 Service Manual ▷ View online
AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 5
*1
: 1: AUTO
2: LEVEL1 3: LEVEL2 4: LEVEL3 5: LEVEL4
6: LEVEL5
*2
: 1: MFT
2: CS1
3: CS2
4: CS3
5: CS4
6: LCC
*3
: 1: R
2: S
2. Enter the adjustment value with the 10-key, and press [OK]
key.
The adjustment value is set.
The adjustment value is set.
3. Set the print condition with the scroll key and the 10-key.
4. Set a document and press [EXECUTE] key.
The document is scanned at the density level set in procedure 2
and it is printed.
4. Set a document and press [EXECUTE] key.
The document is scanned at the density level set in procedure 2
and it is printed.
(Item to be set)
*1
: 1: AUTO
2: LEVEL1
3: LEVEL2
4: LEVEL3
5: LEVEL4
6: LEVEL5
7: AUTO (HALF TONE)
8: LEVEL1 (HALF TONE)
9: LEVEL2 (HALF TONE)
10: LEVEL3 (HALF TONE)
11: LEVEL4 (HALF TONE)
12: LEVEL5 (HALF TONE)
*2
: 1: MFT
2: CS1
3: CS2
4: CS3
5: CS4
6: LCC
*3
: 1: R
2: S
(Item to be set)
*1
: 1: AUTO
2: LEVEL1
3: LEVEL2
4: LEVEL3
5: LEVEL4
6: LEVEL5
7: AUTO (HALF TONE)
8: LEVEL1 (HALF TONE)
9: LEVEL2 (HALF TONE)
10: LEVEL3 (HALF TONE)
11: LEVEL4 (HALF TONE)
12: LEVEL5 (HALF TONE)
*2
: 1: MFT
2: CS1
3: CS2
4: CS3
5: CS4
6: LCC
*3
: 1: R
2: S
46
-42
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Used to adjust the FAX mode (fine text mode)
document scan density (when the FAX is installed).
document scan density (when the FAX is installed).
Section
ICU PWB/FAX
Item
Picture quality
Operation/
Procedure
Procedure
1. Select the print density adjustment mode with the
scroll key.
Item
Set range
Default
A AUTO
Fine text/Auto/
Without half-tone
Without half-tone
1 – 99
50
B LEVEL1
Fine text/ Manual level 1/
Without half-tone
Without half-tone
1 – 99
50
C LEVEL2
Fine text/ Manual level 2/
Without half-tone
Without half-tone
1 – 99
50
D LEVEL3
Fine text/ Manual level 3/
Without half-tone
Without half-tone
1 – 99
50
E LEVEL4
Fine text/ Manual level 4/
Without half-tone
Without half-tone
1 – 99
50
F LEVEL5
Fine text/ Manual level 5/
Without half-tone
Without half-tone
1 – 99
50
G AUTO
(HALF TONE)
Fine text/Auto/With half-tone
1 – 99
50
H LEVEL1
(HALF TONE)
Fine text/ Manual level 1/
With half-tone
With half-tone
1 – 99
50
I
LEVEL2
(HALF TONE)
(HALF TONE)
Fine text/ Manual level 2/
With half-tone
With half-tone
1 – 99
50
J
LEVEL3
(HALF TONE)
(HALF TONE)
Fine text/ Manual level 3/
With half-tone
With half-tone
1 – 99
50
K LEVEL4
(HALF TONE)
Fine text/ Manual level 4/
With half-tone
With half-tone
1 – 99
50
L LEVEL5
(HALF TONE)
Fine text/ Manual level 5/
With half-tone
With half-tone
1 – 99
50
M EXECUTE MODE Print mode
1 – 12
*1
1
N PAPER
Print execution cassette
selection
selection
1 – 6
*2
2
O EXIT TRAY
Paper exit tray selection
1 – 2
*3
1
46
-43
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Used to adjust the FAX mode (super fine mode)
document scan density (when the FAX is installed).
document scan density (when the FAX is installed).
Section
ICU PWB/FAX
Item
Picture quality
Operation/
Procedure
Procedure
1. Select the print density adjustment mode with the
scroll key.
2. Enter the adjustment value with the 10-key, and
press [OK] key.
The adjustment value is set.
The adjustment value is set.
3. Set the print condition with the scroll key and the
10-key.
4. Set a document and press [EXECUTE] key.
The document is scanned at the density level set in
procedure 2 and it is printed.
The document is scanned at the density level set in
procedure 2 and it is printed.
Item
Set range Default
A AUTO
Super fine/ Auto/ Without
half-tone
half-tone
1 – 99
50
B LEVEL1
Super fine/ Manual level 1/
Without half-tone
Without half-tone
1 – 99
50
C LEVEL2
Super fine/ Manual level 2/
Without half-tone
Without half-tone
1 – 99
50
D LEVEL3
Super fine/ Manual level 3/
Without half-tone
Without half-tone
1 – 99
50
E LEVEL4
Super fine/ Manual level 4/
Without half-tone
Without half-tone
1 – 99
50
F
LEVEL5
Super fine/ Manual level 5/
Without half-tone
Without half-tone
1 – 99
50
G AUTO
(HALF TONE)
Super fine/ Auto/ With half-
tone
tone
1 – 99
50
H LEVEL1
(HALF TONE)
Super fine/ Manual level 1/
With half-tone
With half-tone
1 – 99
50
I
LEVEL2
(HALF TONE)
(HALF TONE)
Super fine/ Manual level 2/
With half-tone
With half-tone
1 – 99
50
J
LEVEL3
(HALF TONE)
(HALF TONE)
Super fine/ Manual level 3/
With half-tone
With half-tone
1 – 99
50
K LEVEL4
(HALF TONE)
Super fine/ Manual level 4/
With half-tone
With half-tone
1 – 99
50
L
LEVEL5
(HALF TONE)
(HALF TONE)
Super fine/ Manual level 5/
With half-tone
With half-tone
1 – 99
50
M EXECUTE MODE
Print mode
1 – 12
*1
1
N PAPER
Print execution cassette
selection
selection
1 – 6
*2
2
O EXIT TRAY
Paper exit tray selection
1 – 2
*3
1
AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 6
(Item to be set)
*1
: 1: AUTO
2: LEVEL1
3: LEVEL2
4: LEVEL3
5: LEVEL4
6: LEVEL5
7: AUTO (HALF TONE)
8: LEVEL1 (HALF TONE)
9: LEVEL2 (HALF TONE)
10: LEVEL3 (HALF TONE)
11: LEVEL4 (HALF TONE)
12: LEVEL5 (HALF TONE)
*2
: 1: MFT
2: CS1
3: CS2
4: CS3
5: CS4
6: LCC
*3
: 1: R
2: S
When the adjustment value is changed, the image losses at the
four corners are changed uniformly.
four corners are changed uniformly.
The FAX-related soft SW setting is displayed on the LCD for
checking and changing.
checking and changing.
46
-44
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Used to adjust the FAX mode (ultra-fine mode)
document scan density (when the FAX is installed).
document scan density (when the FAX is installed).
Section
ICU PWB/FAX
Item
Picture quality
Operation/
Procedure
Procedure
1. Select the print density adjustment mode with the
scroll key.
2. Enter the adjustment value with the 10-key, and
press [OK] key.
The adjustment value is set.
The adjustment value is set.
3. Set the print condition with the scroll key and the
10-key.
4. Set a document and press [EXECUTE] key.
The document is scanned at the density level set in
procedure 2 and it is printed.
The document is scanned at the density level set in
procedure 2 and it is printed.
Item
Set range
Default
A AUTO
Ultra-fine/ Auto/ Without
half-tone
half-tone
1 – 99
50
B LEVEL1
Ultra-fine/ Manual level 1/
Without half-tone
Without half-tone
1 – 99
50
C LEVEL2
Ultra-fine/ Manual level 2/
Without half-tone
Without half-tone
1 – 99
50
D LEVEL3
Ultra-fine/ Manual level 3/
Without half-tone
Without half-tone
1 – 99
50
E LEVEL4
Ultra-fine/ Manual level 4/
Without half-tone
Without half-tone
1 – 99
50
F
LEVEL5
Ultra-fine/ Manual level 5/
Without half-tone
Without half-tone
1 – 99
50
G AUTO
(HALF TONE)
Ultra-fine/ Auto/ With half-
tone
tone
1 – 99
50
H LEVEL1
(HALF TONE)
Ultra-fine/ Manual level 1/
With half-tone
With half-tone
1 – 99
50
I
LEVEL2
(HALF TONE)
(HALF TONE)
Ultra-fine/ Manual level 2/
With half-tone
With half-tone
1 – 99
50
J
LEVEL3
(HALF TONE)
(HALF TONE)
Ultra-fine/ Manual level 3/
With half-tone
With half-tone
1 – 99
50
K LEVEL4
(HALF TONE)
Ultra-fine/ Manual level 4/
With half-tone
With half-tone
1 – 99
50
L
LEVEL5
(HALF TONE)
(HALF TONE)
Ultra-fine/ Manual level 5/
With half-tone
With half-tone
1 – 99
50
M EXECUTE MODE Print mode
1 – 12
*1
1
N PAPER
Print execution cassette
selection
selection
1 – 6
*2
2
O EXIT TRAY
Paper exit tray selection
1 – 2
*3
1
49
49
-1
Purpose
Version up
Function
(Purpose)
(Purpose)
Used for firmware version up (Machine/FAX).
Section
Firmware (Machine/FAX)
Item
Operation
Operation/
Procedure
Procedure
1. Press the [EXECUTE] key to enter the Flash
ROM writing mode.
2. Start the download program on the PC side and
perform Flash ROM writing.
50
50
-27
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Used to adjust image loss in the FAX/scanner mode.
Section
FAX/Scanner
Item
Picture quality
Image position
Operation/
Procedure
Procedure
1. Select the adjustment mode with the scroll key.
2. Enter the adjustment value at the selected point,
2. Enter the adjustment value at the selected point,
and press the [OK] key. The entered value is set.
Display
Content
Min.
Value
Max.
Value
Default
A
FAX MODE image loss
0
99
20
B
PUSH SCAN MODE image loss
0
99
30
C
PULL SCAN MODE image loss
0
99
0
66
66
-01
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to change/set the soft SW setting (FAX-related
items). (When the FAX is installed.)
items). (When the FAX is installed.)
Section
FAX
Operation/
Procedure
Procedure
1. Enter the soft SW number to be selected with the
10-key.
2. Change or set the selected soft SW setting.
3. Enter [EXECUTE] key to save the setting.
3. Enter [EXECUTE] key to save the setting.
AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 7
Read/write checks of the EEPROM, the SRAM (G/A), and the
SDRAM on the modem controller and the SRAM and the Flash
ROM on the MFP controller are executed and the results are
displayed.
SDRAM on the modem controller and the SRAM and the Flash
ROM on the MFP controller are executed and the results are
displayed.
(Sendable signals)
∗
The unit of setting is kbps. Setting is made by the key display
name. The item in ( ) is, however, excluded.
name. The item in ( ) is, however, excluded.
(Sendable signals)
∗
The unit of setting is kbps. Setting is made by the key display
name. The item in ( ) is, however, excluded.
name. The item in ( ) is, however, excluded.
66
-02
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to initialize the soft SW setting (FAX-related
items) according to the destination.
(When the FAX is installed.)
items) according to the destination.
(When the FAX is installed.)
Section
FAX
Item
Data
Initializing
Operation/
Procedure
Procedure
1. Enter the destination code with the 10-key, and
press [SET] key.
2. Press the [EXECUTE] key. (YES/NO key
display)
3. When [Yes] key is pressed, the soft SW is
initialized according to the destination code.
(When [No] key is pressed, the operation is
canceled. )
(When [No] key is pressed, the operation is
canceled. )
66
-03
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the memory on the Modem controller.
(When the FAX is installed.)
(When the FAX is installed.)
Section
FAX
Item
Operation
Operation/
Procedure
Procedure
1. Press the [EXECUTE] key.
66
-04
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to select a signal and send it to the line and
speaker (at the max. level).
(When the FAX is installed.)
speaker (at the max. level).
(When the FAX is installed.)
Section
FAX
Item
Operation
Operation/
Procedure
Procedure
The page can be selected with the scroll keys.
1. Select the send mode.
2. Press the [EXECUTE] key.
1. Select the send mode.
2. Press the [EXECUTE] key.
Page.1:
NO SIGNAL (No signal is sent.)
Page.2:
12.0 V33
33.6 V34 (3429)
14.4 V17
31.2 V34 (3429)
12.0 V17
28.8 V34 (3429)
9.6 V17
26.4 V34 (3200Low)
7.2 V17
24.0 V34 (3200Hi)
9.6 V29
21.6 V34 (3200Low)
7.2 V29
19.2 V34 (3000Hi)
4.8 V27t
16.8 V34 (3000Low)
2.4 V27t
14.4 V34 (3000Hi)
0.3 FLG
12.0 V34 (2800)
CED 2100
9.6 V34 (2800)
CNG 1100
7.2 V34 (2800)
0.3 V21
4.8 V34 (2400)
ANSam
2.4 V34 (2400)
RINGER
14.4 V33
No RBT
66
-05
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to select a signal and send it to the line and
the speaker. (Level: Soft SW setting)
(When the FAX is installed.)
the speaker. (Level: Soft SW setting)
(When the FAX is installed.)
Section
FAX
Item
Operation
Operation/
Procedure
Procedure
The page can be selected with the scroll keys.
1. Select the send mode.
2. Press the [EXECUTE] key.
1. Select the send mode.
2. Press the [EXECUTE] key.
Page.1:
NO SIGNAL (No signal is sent.)
Page.2:
12.0 V33
33.6 V34 (3429)
14.4 V17
31.2 V34 (3429)
12.0 V17
28.8 V34 (3429)
9.6 V17
26.4 V34 (3200Low)
7.2 V17
24.0 V34 (3200Hi)
9.6 V29
21.6 V34 (3200Low)
7.2 V29
19.2 V34 (3000Hi)
4.8 V27t
16.8 V34 (3000Low)
2.4 V27t
14.4 V34 (3000Hi)
0.3 FLG
12.0 V34 (2800)
CED 2100
9.6 V34 (2800)
CNG 1100
7.2 V34 (2800)
0.3 V21
4.8 V34 (2400)
ANSam
2.4 V34 (2400)
RINGER
14.4 V33
No RBT
AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 8
(Sendable message)
(Sendable message)
66
-06
Purpose
Data output/check
Function
(Purpose)
(Purpose)
Used to print the check list of the contents when
confidential registration is made.
(When the FAX is installed.)
confidential registration is made.
(When the FAX is installed.)
Section
FAX
Item
Data
Confidential pass code
Operation/
Procedure
Procedure
1. Press the [EXECUTE] key.
The confidential registration check list (Box No., BOX
name, and print pass code) is printed. (If there is no
registration, print is not made.)
The confidential registration check list (Box No., BOX
name, and print pass code) is printed. (If there is no
registration, print is not made.)
66
-07
Purpose
Data output/check
Function
(Purpose)
(Purpose)
Used to print all the images in the memory.
(When the FAX is installed.)
(When the FAX is installed.)
Section
FAX
Item
Data
Image data
Operation/
Procedure
Procedure
1. Press the [EXECUTE] key.
All the image data saved in the image memory are
outputted.
All the image data saved in the image memory are
outputted.
∗
The confidential receive data are also outputted.
66
-08
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to select a voice message and send it to the
line and the speaker (at the max. level).
(When the FAX is installed.)
line and the speaker (at the max. level).
(When the FAX is installed.)
Section
FAX
Item
Operation
Operation/
Procedure
Procedure
1. Select the voice message to be sent.
2. Press the [EXECUTE] key.
2. Press the [EXECUTE] key.
NONE
Mute
PAUSE
Hold-on melody
MESSAGE1
Message 1
MESSAGE2
Message 2
MESSAGE3
Message 3
MESSAGE4
Message 4
MESSAGE5
Message 5
MESSAGE6
Message 6
ALARM
Alarm
RINGER
Calling melody (speaker)
EXT.TEL.RINGER
External telephone call
66
-09
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to select a signal and send it to the line and
the speaker. (Level: soft SW setting).
(When the FAX is installed.)
the speaker. (Level: soft SW setting).
(When the FAX is installed.)
Section
FAX
Item
Operation
Operation/
Procedure
Procedure
1. Select the voice message to be sent.
2. Press the [EXECUTE] key.
2. Press the [EXECUTE] key.
NONE
Mute
PAUSE
Hold-on melody
MESSAGE1
Message 1
MESSAGE2
Message 2
MESSAGE3
Message 3
MESSAGE4
Message 4
MESSAGE5
Message 5
MESSAGE6
Message 6
ALARM
Alarm
RINGER
Calling melody (speaker)
EXT.TEL.RINGER
External telephone call
66
-10
Purpose
Data clear
Function
(Purpose)
(Purpose)
All the images in the memory can be deleted.
(When the FAX is installed.)
(When the FAX is installed.)
Section
FAX
Item
Data
Image data
Operation/
Procedure
Procedure
1. Press the [EXECUTE] key.
All the image data saved in the image memory are
deleted.
All the image data saved in the image memory are
deleted.
∗
Confidentially received data are also deleted.