DOWNLOAD Sharp AR-FX10 Service Manual ↓ Size: 3.84 MB | Pages: 100 in PDF or view online for FREE

Model
AR-FX10
Pages
100
Size
3.84 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service manual
File
ar-fx10.pdf
Date

Sharp AR-FX10 Service Manual ▷ View online

AR-FX10  SIMULATIONS, FAX SOFTWARE SWITCH  6 - 1
[6] SIMULATIONS, FAX SOFTWARE SWITCH
1. Entering the simulation mode
a. Nomal mode
Enter the copy mode and perform the following procedures.
[P]  
[*]  
[C]  
[*]  
[Main 
code]  
[START]  
[Sub 
code]  
[START]
b. FAX mode
Enter the copy mode and perform the following procedures.
[9]  
[*]  
[8]  
[#]  
[7]
2. Switching the simulation mode
Press [CUSTOM SETTINGS] to return to the code entry screen. 
3. Canceling the simulation mode
Press [CA] key to cancel the simulation mode.
4. Simulation list
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
22
5
Used to check the ROM version of 
each unit (section).
Others
Software
6
Used to print the setting and 
adjustment data list.
Adjustment/Setting/
Operation data output, 
check (display, print)
Data
Setting/
Adjustment data
11
Used to check the number of use of 
FAX. (When the FAX is installed)
Adjustment/Setting/
Operation data output, 
check (display, print)
FAX
Counter
24
10
Used to clear the FAX counter. 
(When the FAX is installed)
Data clear
FAX
Counter
46
40
Collective adjustment of FAX mode 
(all modes) document scan density 
(When the FAX is installed)
Adjustment
ICU PWB / FAX
Picture quality
41
Used to adjust the FAX mode 
(normal mode) document scan 
density  (when the FAX is installed).
Adjustment
ICU PWB / FAX
Picture quality
42
Used to adjust the FAX mode (fine 
text mode) document scan density  
(when the FAX is installed).
Adjustment
ICU PWB / FAX
Picture quality
43
Used to adjust the FAX mode (super 
fine mode) document scan density 
(when the FAX is installed).
Adjustment
ICU PWB / FAX
Picture quality
44
Used to adjust the FAX mode (ultra-
fine mode) document scan density 
(when the FAX is installed).
Adjustment
ICU PWB / FAX
Picture quality
49
1
Used for firmware version up 
(Machine/FAX).
Version up
Firmware (Machine/FAX)
Operation
50
27
Used to adjust image loss in the 
FAX/scanner mode.
Adjustment
FAX/Scanner
Picture quality
66
01
Used to change/set the soft SW 
setting (FAX-related items). (When 
the FAX is installed.)
Setting
FAX
02
Used to initialize the soft SW setting 
(FAX-related items) according to the 
destination. (When the FAX is 
installed.)
Setting
FAX
Data
Initializing
03
Used to check the memory on the 
Modem controller. (When the FAX is 
installed.)
Operation test/check
FAX
Operation
04
Used to select a signal and send it to 
the line and speaker (at the max. 
level). (When the FAX is installed.)
Operation test/check
FAX
Operation
05
Used to select a signal and send it to 
the line and the speaker. (Level: Soft 
SW setting) (When the FAX is 
installed.)
Operation test/check
FAX
Operation
06
Used to print the check list of the 
contents when confidential 
registration is made. (When the FAX 
is installed.)
Data output/check
FAX
Data
Confidential pass 
code
07
Used to print all the images in the 
memory. (When the FAX is 
installed.)
Data output/check
FAX
Data
Image data
AR-FX10  SIMULATIONS, FAX SOFTWARE SWITCH  6 - 2
66
08
Used to select a voice message and 
send it to the line and the speaker (at 
the max. level). (When the FAX is 
installed.)
Operation test/check
FAX
Operation
09
Used to select a signal and send it to 
the line and the speaker. (Level: soft 
SW setting). (When the FAX is 
installed.)
Operation test/check
FAX
Operation
10
All the images in the memory can be 
deleted. (When the FAX is installed.)
Data clear
FAX
Data
Image data
11
Used to select a pattern and send it 
to the line and the speaker at 300bps 
(at the max. level). (When the FAX is 
installed.)
Operation test/check
FAX
Operation
12
Used to select a pattern and send it 
to the line and the speaker at 
300bps. (Level: soft SW setting) 
(When the FAX is installed.)
Operation test/check
FAX
Operation
13
Used to register a dial number for 
test used in SIM 66-14/15/16. (When 
the FAX is installed.)
Setting
FAX
Data
Registration
14
Used to adjust and check the make 
time of dial pulse (10pps). (When the 
FAX is installed.)
Adjustment
FAX
Operation
15
Used to adjust and check the make 
time of the dial pulse (20pps). (When 
the FAX is installed.)
Adjustment
FAX
Operation
16
Used to adjust and check the send 
level of DTFM signal. (When the 
FAX is installed.)
Adjustment
FAX
Operation
17
Used to select the DTFM signal  (1 – 
9, 0, *, #)  to send it to the line and 
the speaker (at the max. level). 
(When the FAX is installed.)
Operation test/check
FAX
Operation
18
Used to select the DTFM signal  (1 – 
9, 0, *, #)  to send it to the line and 
the speaker (Level: soft SW setting). 
(When the FAX is installed.)
Operation test/check
FAX
Operation
19
Used to write the ICU PWB SRAM 
contents (various set values and 
user data) into the Flash ROM (AR-
MM9). (When the FAX is installed.)
Backup
FAX
Data
20
Used to write the Flash ROM (AR-
MM9) contents (SRAM contents 
written with SIM 66-19) into the ICU 
PWB SRAM. (When the FAX is 
installed.)
Backup
FAX
Data
21
Used to print various registration 
information, communication, file 
management, system error, and 
protocol information. (When the FAX 
is installed.)
Check
FAX
Data
22
Used to set the sound volume of the 
handset. (When the FAX is 
installed.)
Setting
FAX
Operation
23
Used to download the FAX program. 
(When the FAX is installed.)
Setting
FAX
Operation
24
Used to clear the data in the FAST 
memory. (When the FAX is 
installed.)
Data clear
FAX
Data
Initializing
29
Used to clear the data related to the 
address book (one-touch 
registration, program registration/
expansion, interface memory box 
registration, each table contents). 
(When the FAX is installed.)
Data clear
FAX
Data
Initializing
30
Used to check the status change of 
the TEL/LIU sensor. (When the FAX 
is installed.)
Operation test/check
FAX
Operation
31
Used to set ON/OFF of each port for 
output to the TEL/LIU. (When the 
FAX is installed.)
Setting
FAX
Operation
32
Used to check (compare) the 
received data (fixed data) from the 
line to make judgment of error or 
normal. (When the FAX is installed.)
Operation test/check
FAX
Operation
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
AR-FX10  SIMULATIONS, FAX SOFTWARE SWITCH  6 - 3
5. Detail of simulations
(Sections to be displayed)
66
33
Used to detect signals (BUSY 
TONE/CNG/CED/FNET) from the 
line. (When the FAX is installed.)
Operation test/check
FAX
Operation
34
Used to display the time required for 
sending the test image data. (When 
the FAX is installed.)
Operation test/check
FAX
Operation
35
Used to rewrite the Modem program. 
(When the FAX is installed.)
Setting
FAX
Data
Writing
36
Used to check send/receive (data/
command line) from the Modem 
controller to the MFP controller.
(When the FAX is installed)
Operation test/check
FAX
Operation
39
Used to set the destination of the 
FAX. (When the FAX is installed.)
Setting
FAX
Specifications
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
22
22
-5
Purpose
Others
Function 
(Purpose)
Used to check the ROM version of each unit 
(section).
Item
Software
Operation/
Procedure
If there is any problem in the software, check the 
ROM version of each section with this simulation 
and replace with a new version if necessary.
ICU
ICU control 
PCU
Engine control section
SCANNER
Scanner control section
COL REV DATA
Color correction ROM
OPE PROG
OPE control section
PRT BOOT
PRT boot
PRT PROG
PRT control section
FAX
FAX control section
FIN-SORTER
Finisher/Sorter
PUNCH
Punch unit
DESK
Desk
LCC
Large capacity cassette
NIC
NIC
PS
PostScript
22
-6
Purpose
Adjustment/Setting/Operation data output, check, 
(display, print)
Function 
(Purpose)
Used to print the setting and adjustment data list.
Item
Data
Setting/Adjustment data
Operation/
Procedure
When installing or servicing, execute this simulation 
to print and store the adjustment values and setting 
data for use in the next servicing. (Memory trouble, 
PWB replacement, etc.)
In this case, the print conditions can be set 
optionally.
1. Select the setup item. (The selected item is 
highlighted.)
2. Set the item and conditions with the 10-key pad.
3. Press the [EXECUTE] key to print various data.
Item
Display item
Low High Default
Description
A
DATA PATTERN
1
1
1
=1
B
PAPER SELECT
1
6
2
Cassette selection
=1
MANUAL
Manual paper feed
=2
CAS1
Cassette 1
=3
CAS2
Cassette 2
=4
CAS3
Cassette 3
=5
CAS4
Cassette 4
=6
LCC
LCC
AR-FX10  SIMULATIONS, FAX SOFTWARE SWITCH  6 - 4
(Counter values to be displayed)
(Counters to be cleared)
1. Select the print density adjustment mode with the scroll key.
2. Enter the adjustment value with the 10-key, and press [OK] 
key.
The adjustment value is set.
3. Set the print condition with the scroll key and the 10-key.
4. Set a document and press [EXECUTE] key.
The document is scanned at the density level set in procedure 2 
and it is printed.
(Item to be set)
*1
: 1: MFT
2: CS1
3: CS2
4: CS3
5: CS4
6: LCC
*2
: 1: R
2: S
2. Enter the adjustment value with the 10-key, and press [OK] 
key. 
The adjustment value is set.
3. Set the print condition with the scroll key and the 10-key.
4. Set a document and press [EXECUTE] key.
The document is scanned at the density level set in procedure 2 
and it is printed.
(Item to be set)
22
-11
Purpose
Adjustment/Setting/Operation data output, check 
(display, print)
Function 
(Purpose)
Used to check the number of use of FAX. 
(When FAX installed)
Section
FAX
Item
Counter
Operation/
Procedure
The FAX send/receive counter value is displayed. 
Display
Content
FAX SEND
FAX send counter
FAX RECEIVED
FAX receive counter
FAX OUTPUT
FAX print number
SEND IMAGES
FAX send number counter
SEND TIME
FAX send time
RECEIVED TIME
FAX receive time
24
24
-10
Purpose
Data clear
Function 
(Purpose)
Used to clear the FAX counter. (with FAX installed)
Section
FAX
Item
Counter
Operation/
Procedure
1. Select the counter to be cleared.
2. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
3. Select YES or NO to clear the counter.
YES: Clear
NO: Not clear
Display
Content
FAX SEND
FAX send counter
FAX RECEIVED
FAX receive counter
FAX OUTPUT
FAX print number
SEND IMAGES
FAX send number counter
SEND TIIME
FAX send time
RECEIVE TIME
FAX receive time
46
46
-40
Purpose
Adjustment
Function 
(Purpose)
Collective adjustment of FAX mode (all modes) 
document scan density (when FAX is installed)
Section
ICU PWB/FAX
Item
Picture quality
Operation/
Procedure
The print densities of all the modes (FAX modes) 
can be collectively and uniformly changed with the 
adjusted density level of each mode (normal, fine 
text, super fine, ultra fine) as the start point.
Item
Set range
Default
A AUTO
Exposure data value 
(Collective)
1 to 99
50
B PAPER
Print execution cassette 
selection
1 to 6
*1
2
C EXIT TRAY
Paper exit tray selection
1 to 2
*2
2
46
-41
Purpose
Adjustment
Function 
(Purpose)
Used to adjust the FAX mode (normal mode) 
document scan density  (when the FAX is installed).
Section
ICU PWB/FAX
Item
Picture quality
Operation/
Procedure
1. Select the print density adjustment mode with the 
scroll key.
Item
Set range Default
A AUTO
Automatic
1 to 99
50
B LEVEL1
Manual level 1
1 to 99
50
C LEVEL2
Manual level 2
1 to 99
50
D LEVEL3
Manual level 3
1 to 99
50
E LEVEL4
Manual level 4
1 to 99
50
F LEVEL5
Manual level 5
1 to 99
50
G EXECUTE MODE Print mode
1 to 6
*1
1
H PAPER
Print execution 
cassette selection
1 to 6
*2
2
I
EXIT TRAY
Paper exit tray 
selection 
1 to 2
*3
1
Page of 100
Display