Sharp AR-C200P (serv.man4) Service Manual ▷ View online
AR-C200P Rev.5
33 /
1
2
3
2.3.7
Cassette Assy/ Front Cover Assy/ Front Cover Inner Baffle
(1) Detach the cassette Assy
1
.
(2) Open the front cover
2
, and disengage it at two places to detach it.
(3) Detach the front cover inner baffle
3
.
Figure 2-3-7 Cassette Assy/ Front Cover Assy/ Front Cover Inner Baffle
AR-C200P Rev.5
34 /
1
3
2
2.3.8
Retard Pad Assy/ Retard Pad Assy Spring
(1) Remove the cassette
1
.
(2) Detach the retard pad Assy
2
(at the same time, the spring
3
becomes detached).
Figure 2-3-8 Retard Pad Assy/ Retard Pad Assy Spring
AR-C200P Rev.5
35 /
1
2
2.3.9
Feed Roller and Nudger Roller
(1) Remove the cassette.
(2) Unlatch and demount the feed roller
1
.
(3) Unlatch and demount the nudger roller
2
.
Figure 2-3-9 Feed Roller and Nudger Roller
AR-C200P Rev.5
36 /
2
1
3
1
1
2.3.10 Rear Cover
(1) Remove the left side cover (see section 2.3.12).
(2) Remove the four screws
1
to detach the rear cover
2
.
Note! When attaching the rear cover, take care not to allow the spring
3
to get caught in parts.
Figure 2-3-10 Rear Cover
Click on the first or last page to see other AR-C200P (serv.man4) service manuals if exist.