Sharp AR-C200P (serv.man4) Service Manual ▷ View online
AR-C200P Rev.5
17 /
(2)
Do not disassemble the printer so long as it operates properly.
(3)
Minimize the disassembly. Do not detach parts other than those shown in the replacing procedure.
(4)
For maintenance, use designated tools.
(5)
Follow the order instructed to disassemble the printer. Incorrect order may damage the parts.
(6)
Small parts such as screws and collars tend to get lost, so temporarily place and fix them in
their original positions.
their original positions.
(7)
When handling ICs and circuit boards such as microprocessors, ROMs and RAMs, do not use
gloves that likely to have static.
gloves that likely to have static.
(8)
Do not place the printed circuit boards directly on the printer or the floor.
2.
PARTS REPLACEMENT
This section describes the procedure for replacing the parts, assemblies and units in the field. The
replacing procedure is given for detachment. To attach, use the reverse procedure.
replacing procedure is given for detachment. To attach, use the reverse procedure.
2.1
Precautions in Replacing Parts
(1)
Before replacing the parts, be sure to remove the AC cable and the interface cable.
(a) To remove the AC cable, always use the following procedure.
i)
Flip the power switch of the printer off (to “O”).
ii)
Pull the AC inlet plug of the AC cable out of the AC receptable.
iii) Remove the AC cable and the interface cable from the printer.
(b) To connect the printer again, always use the following procedure.
i)
Connect the AC cable and the interface cable to the printer.
ii)
Insert the AC inlet plug into the AC receptacle.
iii) Flip the power switch of the printer on (to “I”).
Disconnect
Connect
AR-C200P Rev.5
18 /
[Maintenance Tools]
Table 2-1 lists tools necessary to replace the printed circuit boards and the units.
Table 2-1 Maintenance Tools
No.
No. 1-100 Philips
screwdriver
screwdriver
Q' ty
Place of use
Remarks
Service Tools
1
2
3
4
5
6
8
No. 2-200 Philips
screwdriver, Magnetized
screwdriver, Magnetized
No. 3-100 screwdriver
No. 5-200 screwdriver
Digital multimeter
Pliers
Handy cleaner
LED Head cleaner
High voltage probe
1
1
1
1
1
1
1
2~2.5 mm screws
3~5 mm screws
9
1
7
1
Transparency sheet
( thickness premeasured)
0ZZ42404301//
( thickness premeasured)
0ZZ42404301//
Stage height adjustment jig
0ZZ42423701//
0ZZ42423701//
-
Microdriver
2.0mm
Adjustment for Media
Thickness sensor
Thickness sensor
Adjustment for Media
Thickness sensor
Thickness sensor
Adjustment for Lever
adjust
(Media Thickness)
adjust
(Media Thickness)
10
11
12
1
1
1
Label
AR-C200P Rev.5
19 /
2.2
Parts layout
Figure 2-1
A
A
B
B
A
A
B
AR-C200P Rev.5
20 /
[Top Cover Assy]
Figure 2-2
For 600dpi
Click on the first or last page to see other AR-C200P (serv.man4) service manuals if exist.