C. Manual paper feed clutch 
Disassembly: Set up the shutter arm (1) then remove it. 
Assembly:
Install so that the boss section  of the  fulcrum arm (2)
comes between ribs.
Disassembly: Set up the cam transmission arm (2), and remove it. 
Assembly:
Install so that the cam transmission arm (2) is under
the roller arm (A).
D. Manual transport roller/Manual paper feed roller
Installation: Be careful of the installing direction of the manual
transport roller (4).
( 1 )
( 2 )
( 4 )
( 3 )
( A )
( 7 )
( 5 )
( 6 )
( 8 )
L
C
K
T
O
K
O
( 2 )
( 3 )
( 1 )
( 4 )
( 5 )
AR-162 [11] DISASSEMBLY AND ASSEMBLY 10/5/2000
AR-162 DISASSEMBLY AND ASSEMBLY – 10
E. Multi feed solenoid
Assembly: Install so that the latches (A) and (B) move smoothly. 
10. Power section  
No.
Content
A
Power unit
A. Power unit
11. Developing section 
No.
Contents
A
Developing box
B
Developing doctor
C
MG roller
A. Developing box
B. Developing doctor
Adjustment: Developing doctor gap adjustment
C. MG roller
( 2 )
( 1 )
( 2 )
( A )
( B )
( 3 )
( 4 )
( 5 )
( 3 )
( 3 )
( 4 )
( 2 )
( 1 )
( 1 )
( 1 )
( 1 )
( 1 )
( 2 )
( 1 )
( 1 )
( 2 )
( 1 )
AR-162 [11] DISASSEMBLY AND ASSEMBLY 10/5/2000
AR-162 DISASSEMBLY AND ASSEMBLY – 11
Adjustment: MG roller main pole position adjustment
12. Process section 
No.
Contents
A
Drum unit
B
MC holder unit
C
Cleaning blade
A. Drum unit
B. MC holder unit
C. Cleaning blade
( 3 )
( 4 )
( 5 )
( 6 )
( 3 )
(1)
L O C K
( 2 )
( 3 )
( 2 )
( 1 )
( 1 )
( 2 )
( 1 )
( 1 )
AR-162 [11] DISASSEMBLY AND ASSEMBLY 10/5/2000
AR-162 DISASSEMBLY AND ASSEMBLY – 12
[12] FLASH ROM VERSION UP
PROCEDURE
1. MCU/E-SORT
A. Tool
Machine
PC
Operates on Windows 95/98.
Level converter (UKOG-0002QSZZ) (with serial cable)
Level converter (UKOG-0003QSZZ) (without serial cable)
(Serial cable)
B. Procedures
1) Connect the PC and the level converter, and start Windows.
2) Turn off the power of the machine.
3) Remove the cap at the rear of the machine.
4) Connect the serial connector.
5) Turn on the power of the machine.
The machine enters the download mode. (All LED lamps are
turned off. The machine accepts no key operations.)
6) Execute “mainte-Vxxx.exe” on the PC.
Note Use “mainte_vxxx.exe” ver.1.06 or later.
Since version 1.05 or before cannot identify the model (AR-
162/163/201/206/207/F201), it may erroneously perform writing. In this
case, the machine does not operate properly.
7) Communication port/communication speed setting
Select “Comport” in the option menu, and select the most
suitable item with consideration of PC environment, work time,
etc.
8) Select “Download the Program Data” in the SPECIAL folder, and
transfer data.
AR-162 FLASH ROM VERSION UP PROCEDURE – 1