DOWNLOAD Sharp AR-163 (serv.man4) Service Manual ↓ Size: 2.59 MB | Pages: 71 in PDF or view online for FREE

Model
AR-163 (serv.man4)
Pages
71
Size
2.59 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR163 206-Service Manual
File
ar-163-sm4.pdf
Date

Sharp AR-163 (serv.man4) Service Manual ▷ View online

Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
22
16
Duplex print counter
display
<Only AR-206/207>
Used to display the current duplex print counter value. 
1
17
Copy counter display
Used to display the current copy counter value. 
1
18
Printer counter display
<Only when a printer
function is installed>
Used to display the current printer counter value. 
1
19
Electronic sort counter
display <Only when an E-
sort function is
installed>
Used to display the current electronic sort counter value. 
1
21
Scanner counter display
Used to display the current scanner counter value.
24
1
JAM memory, JAM
counter clear
Used to clear the JAM memory and the JAM counter. 
2
2
Trouble memory clear
Used to clear the trouble memory. 
2
4
SPF counter clear
<Only when an
SPF/RSPF is installed>
Used to clear the SPF counter. 
2
5
Duplex counter clear
<Only AR-206/207>
Used to clear the duplex counter. 
2
6
Paper feed counter clear
Used to clear the paper feed counter. 
2
7
Drum counter clear
Used to clear the drum counter. 
2
8
Copy counter clear
Used to clear the copy counter. 
2
9
Printer counter clear
<Only when a printer
function is installed>
Used to clear the printer counter. 
2
10
Electronic sort counter
clear <Only when an E-
sort function is
installed>
Used to clear the electronic sort counter. 
2
13
Scanner counter clear
Used to clear the scanner counter. 
2
25
1
Main motor operation
check
Execute the simulation with the developer cartridge removed, and the
main motor will rotate for 30 sec. At that time, the cooling motor rotates
at a low speed.
10
Polygon motor operation
check
Used to drive the polygon motor for 30 sec.
2: Display after clearing each counter 
000 (0.75 sec) 
 Blank (0.35 sec) 
 000 (0.75 sec) 
 Blank (1.0 sec) 
 Repetition
AR-162 SIMULATIONS – 6
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
26
1
Option switch display
Used to display the installed option on the operation panel. (The LED
corresponding to the installed option is lighted.)
3
Auditor setting
Used to display the current auditor setting with the numbers at right. 
After entering the set value, press the start key, and the set value is
stored.
0
  2
5
Counter mode setting
Used to set the print counter mode in A3 or 11" 
×
 17".
Used to display the currently set counter value with the numbers at right.
After entering the set value, press the start key, and the set value is
stored.
0
  3
Key
operation
Display
Display
select: 
 
Magnification 
ratio display
key
<Lighting with an option installed>
When “A” is displayed:
Shifter: Paper empty LED
Job separator: JAM LED
SPF: SPF select LED
RSPF: SPF JAM LED
Duplex mode: Main cassette select LED
Simplex mode: Multi manual paper feed select LED
MCU JMPER1: Top of the magnification ratio display
MCU JMPER2: 2nd of the magnification ratio display
MCU JMPER3: 3rd of the magnification ratio display
MCU JMPER7: 4th of the magnification ratio display
MCU JMPER7: 5th of the magnification ratio display
MCU JMPER7: 6th of the magnification ratio display
MCU JMPER7: 7th of the magnification ratio display
MCU JMPER8: Bottom of the magnification ratio
               display
When “b” is displayed:
Cassette (2nd step): No. 2 cassette select LED
Cassette (3rd step): No. 3 cassette select LED
Cassette (4th step): No. 4 cassette select LED
Memory installed: Paper empty LED
FAX: JAM LED
Printer: Main body JAM LED
ERDH: Main cassette select LED
16CPM: SPF JAM LED
20CPM: SPF select LED
Document sensor: Auto paper select LED
Key operation/Display
0: Built-in auditor
1: Coin vendor
2: Others
Key operation/Display
0: Total/Developer = 2 counts
Maintenance = 2 counts
1: Total/Developer = 1 count
Maintenance = 2 counts
2: Total/Developer = 2 counts
Maintenance = 1 count
3: Total/Developer = 1 count
Maintenance = 1 count
AR-162 SIMULATIONS – 7
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
26
6
Destination setting
Used to display the current destination setting with the numbers at right.
After entering the set value, press the start key, and the set value is
stored.
0
 11
7
CRUM set value display
The currently set value of CRUM is displayed with the following numbers:
10
Model name setting
Used to set the model name of the machine used with the following
numbers. After entering the set value, press the start key and the set
value is stored.
0
 30
22
Language setting
Used to display the current setting of the language information with the
number at right. After entering the set value, press the start key, and the
set value is stored.
0
  7
30
CE mark conformity
control setting
Used to display the current setting of CE mark conformity control with
the number at right. After entering the set value, press the start key, and
the set value is stored.
0
  1
32
Fan rotation duty change
state setup
The currently set fan motor rotation duty is displayed with the following
numbers. After entering the set value, press the start key to store the
set value.
0
0.1
Key operation/Display
  0: Japan
  8: EX AB series
  1: USA (Inch series)
  9: EX inch series (FC conformity)
  2: Canada (Inch series)
10: EX AB series (FC conformity)
 3: Germany 1 (AB series)
    (Australia, Newzealand)
  4: UK (AB series)
11: China (AB series)
  5: Not used
12: Taiwan (AB series)
  6: France (AB series)
13: Germany 2 (AB series)
  7: EX inch series
Key operation/Display
  0: Not set
  3: BTA-C
 1: BTA-A
99: Conv
 2: BTA-B
Key operation/Display
 0: AL-1600
11: AR-N200
23: AR-162/S162
 1: AL-1610
12: AR-N205
24: AR-163/S163
 2: AL-1620
13: AL-1621
25: AR-201S
 3: AL-1640/AL-1641
14: AL-1650
26: AR-201/S201
 4: AR-160/AR-S160
15: AL-1670
27: AR-206/S206
 5: AR-161/AR-S161
16: AR-F200
28: AR-207
 6: AR-200S
17: DM-2000
29: ARF161
 7: AR-200/AR-S200
18: DM-2005
30: ARF201
 8: AR-205/AR-S205
19: DM-2010
 9: AR-F160
20: DM-2015
10: AR-F205
Key operation/Display
0: Japanese
4: Italian
1: English
5: Dutch
2: French
6: Swedish
3: German
7: Spanish
Key operation/Display
0: CE mark control OFF
1: CE mark control ON
Key operation/Display
0: Operating 50%, standby 30%
1: Operating 80%, standby 50%
AR-162 SIMULATIONS – 8
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
26
37
Cancel of stop at
developer life over
The currently set value is displayed. Enter a set value and press the
START key, then the set value is registered.
1
  1
38
Cancel of stop at drum
life over
<Not Used>
The currently set value is displayed. After entering the set value, press
the start key to store the set value.
0
  1
42
Transfer timing adjustment
After completion of warm up, shading is performed and the currently set
transfer timing adjustment value is displayed.
5
1, 3, 5, 7, 9
50
Black-white reversion
function setup
The current setup of black-white reversion is displayed with the following
numbers. After entering the set value, press the start key to store the
set value.
0
0.1
51
Sort/Group copy
temporary stop function
setup
<Only when an E-sort
function is installed>
Used to set whether temporary stop for every 250-sheet print (150-sheet
print when the job separator is installed) is made or not during copying
with the sort/group function. The current setup is displayed with the
following numbers. After entering the set value, press the start key to
store the set value.
1
0.1
30
1
Machine sensor operation
check
Used to check the sensors in the machine transport system with LED on
the operation panel.
41
2
OC document sensor
adjustment
<Other than AR-162>
Used to read the document sensor input value with paper and perform
the sensor detection level adjustment. For the adjustment procedure of
the document sensor input value, refer to the previous descriptions.
Key operation/Display
0: Stops the machine at developer life over.
1: Does not stop the machine at developer life over.
Key operation/Display
0: The machine stops at drum life over.
1: The machine does not stop at drum life over.
Key operation
Transfer timing adjustment value: Copy quantity keys
“1”: 240 ms
“3”: 260 ms
“5”: 280 ms
“7”: 300 ms
“9”: 320 ms
Key operation/Display
0: Black-white reversion function enabled
1: Black-white reversion function disabled
Key operation/Display
0: Does not stop.
1: Stops.
Display
<Lighting at sensor ON>
Paper entry sensor: Machine position JAM LED
Duplex sensor: SPF JAM LED <Only AR-206/207>
Paper exit sensor: JAM LED
No. 2 cassette transport sensor: No. 2 cassette position LED
No. 3 cassette transport sensor: No. 3 cassette position LED
<Only when an option is installed>
No. 4 cassette transport sensor: No. 4 cassette position LED
<Only when an option is installed>
Drum initial SW: DRUM LED