DOWNLOAD Sharp AL-1551 (serv.man10) Service Manual ↓ Size: 3.3 MB | Pages: 127 in PDF or view online for FREE

Model
AL-1551 (serv.man10)
Pages
127
Size
3.3 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Copying Equipment / AL1043, AL1252, AL1452 and AL155 Operation Manual
File
al-1551-sm10.pdf
Date

Sharp AL-1551 (serv.man10) User Manual / Operation Manual ▷ View online

DG
B
1-39
S  H  A  R  P
Date Revised : Aug.7, 2001
Date Issued : Jun.1, 1998
MATERIAL  SAFETY  DATA  SHEET  (1/4)
MSDS No. F-00831
1.  PRODUCT  AND COMPANY IDENTIFICATION
Product Name
  :   AL-100TD / DM-150TD / AL-110TD / AL-110DC (Black Toner)
Supplier Identification
 : Sharp Corporation
     22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
    Local suppliers are listed below.  Please contact the nearest supplier for additional information.
(Country)
(Name  and  Telephone  Number)
U.S.A.
Sharp Electronics Corporation
Telephone number for information :1-800-237-4277
Emergency telephone number
:1-800-255-3924
Canada
Sharp Electronics of Canada Ltd.
Telephone number for information : 905-890-2100
Emergency telephone number
:1-800-255-3924
United
Sharp Electronics (U.K.) Ltd.
Kingdom
Telephone number for information : 01922-474013
Australia
Sharp Corporation of Australia PTY. Ltd.
Telephone number for information : 1300-12-50-22
Germany
Sharp Electronics (Europe) GMBH
Telephone number for information : 40-2376-2737
2.  COMPOSITION/INFORMATION ON INGREDIENTS
Substance [ ]
Preparation [ X ]
Ingredient
CAS No.
Proportion   OSHA PEL ACGIH TLV
MAK-TWA    NOHSC-TWA
Styrene-Acrylate 29497-13-1
 35-45%
Not listed
Not listed
Not listed
Not listed
copolymer
Styrene-
9002-52-6
35-45%
Not listed
Not listed
Not listed
Not listed
homopolymer
Carbon black
1332-86-4
5-10%
3.5g/m
3
3.5g/m
3
Not listed
3.5g/m
3
Iron oxide
1317-61-9
5-10%
Not listed
Not listed
Not listed
Not listed
Polypropylene 9010-79-1
1-5%
Not listed
Not listed
Not listed
Not listed
parafirine
8002-73-2
1-5%
Not listed
Not listed
Not listed
Not listed
3.  HAZARDOUS  IDENTIFICATION
Most Important Hazards and Effects of the Products
Human  Health  Effects  : There are no anticipated carcinogenic effects from exposur based on animal tests
performed using toner. When used as intented according to instructions, studies
do not indicate any symptons fibrosis will occur.
Environmental Effects : No data are available.
Specific hazards :
Dust explosion (like most finely dicided organic powders).
4.  FIRST-AID-MEASURES
Route(s) of Entry  :
Inhalation?
Skin?
Ingestion?
    Yes
 No
Possible but very unusual.
Inhalation :
Remove to fresh air. If symptons occur, consult medical personnel.
Skin Contact : Wash with soapand water for 15 minutes or until particle is removed.
If irritation does occur, consult medical personnel.
Eye Contact :
Flush eyes immediately with water for 15 minutes. If irritation does occur, consult
medical personnel.
Ingestion :
Rinse with water and drink several glasses of water. If irritation or discomfort does
occur, consult medical personnel.
DG
B
1-40
S  H  A  R  P
Date Revised : Aug.7, 2001
Date Issued : Jun.1, 1998
MATERIAL  SAFETY  DATA  SHEET  (2/4)
MSDS No. F-00831
5.  FIRE-FIGHTING MEASURES
Extinguishing Media
:  water, CO
2
, foam and dry chemicals
Special Fire fighting Procedure :  None
Fire and Explosion Hazards
:  Toner material, like most finely divided organic powders, may
   form an explosive mixture.
6.  ACCIDENTAL RELEASE MEASURES
Personal Precautions
:
None
Environmental Precautions :
None
Methods for Cleaning Up
:
Wipe off with paper or cloth. Do not use vacuum cleaner when a large
amount is released. It, like finely divided organic powders, is capable
of creating dust explosion.
7.  HANDLING AND STORAGE
Handling
Technical Measures
: None
Precautions
: None
Safe Handling Advice : Use of a dust mask is recommended when handling a large quantity of toner or
during long term exposure, as with any non-toxic dust. Try not to disperse the
particles.
Storage
Technical measures
: None
Storage  Conditions
: Keep container closed and Store in a cool and dry place.
Keep out of the reach of children.
Incompatible Products : None
8.  EXPOSURE CONTROLS/PERSONAL PROTECTION
Engineering Measures
Ventilation
: Not required under intended use.
Exposure limit values
OSHA-PEL(USA)
: 15g/m
3
 (Total Dust), 5g/m
3
 (Respirable Dust)
ACGIH-TLV(USA)
: 10g/m
3
 (Total Dust), 3g/m
3
 (Respirable Dust)
Personal Protective Equipment
Respiratory Protection
: Not required under intended use.
Hand Protection
: Not required under intended use.
Eye Protection
: Not required under intended use.
Skin Protection
: Not required under intended use.
Other  Protective  equipment : Use of a dust mask and goggles are recommended when handling a
large quantity of toner or during long term exposure, as with any non-
toxic dust.
9.  PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Physical State :
  Solid Form : Powder
Color : Black
Oder  :  Odorless
Ph
: Not applicable
Boiling/Melting point
: Not applicable
Softening Point (°C)
: No data
Flash Point (°C)
: Not applicable
Ignition Point (°C)
: No data
Explosion Properties
: No data
Density (g/cm
3
)
: 1.1 (bulk density : 0.34)
Solubility in water
: Negligible
DG
B
1-41
S  H  A  R  P
Date Revised : Aug.7, 2001
Date Issued : Jun.1, 1998
MATERIAL  SAFETY  DATA  SHEET  (3/4)
MSDS No. F-00831
10.  STABILITY AND REACTIVITY
Stability
:Stable
Hazardous Reactions
:Dust explosion, like most finely divided organic powders.
Conditions to avoid
: Electri discharge, throwing into fire.
Materials to avoid
: Oxidizing Materials
Hazardous Decomposition Products : Co, CO
2
 and NO
x
Further Information
: None
11.  TOXICOLOGICAL INFORMATION
Acute Toxicity
Ingestion (oral) : LD50 > 2000mg/kg (Rats)
Dermal
: LD 50 > 2000mg/kg (rats
Inhalation
: No  data
Eye irritation
: Not an irritant
Skin irritation
: Not an irritant
Skin sensitizer : No  sensitization
Mutagenicity
: Negative (Ames Test)
Carcinogenicity
: In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible
human carcinogen).  This classification is given to chemicals for which there is inade-
quate human evidence, but sufficient animal evidence on which to base an opinion
of carcinogenicity.  The classification is based upon the development of lung tumors
in rats receiving chronic inhalation exposures to free carbon black at levels that induce
particle overload of the lung.  Studies performed in animal models other than rats
did not show any association between carbon black and lung tumors.
Moreover, a two-year cancer bioassay using a typical toner preparation containing
carbon black demonstrated no association between toner exposure and tumor
development in rats.
Chronic Effects
In a study in rats of chronic inhalation exposure to a typical toner, a mild to moderate
degree of lung fibrosis was observed in 92% of the rats in the high concentration (16mg/m
3
)
exposure group, and a minimal to mild degree of fibrosis was noted in 22% of the
animals in the middle (4mg/m
3
) exposure group, but no pulmonary change was
reported in the lowest (1mg/m
3
) exposure group, the most relevant level to potential
human exposures.
12.  ECOLOGICAL INFORMATION
No data are available.
13.  DISPOSAL CONSIDERATIONS
Waste from residues
:Waste material may be dumped or incinerated under conditions which meet
all federal, state and local environmental regulations.
Contaminated Packaging : Waste may be disposed or incinerated under conditions which meet all
federal, state and local environmental regulations.
DG
B
1-42
S  H  A  R  P
Date Revised : Aug.7, 2001
Date Issued : Jun.1, 1998
MATERIAL  SAFETY  DATA  SHEET  (4/4)
MSDS No. F-00831
14.  TRANSPORT INFORMATION
UN Classification
:None
Land
 DOT (USA)
:None
Sea
 IMDG
: None
Air
 ICAO-TI
: None
15.  REGULATORY INFORMATION
US Information
TSCA (Toxic Substances Control Act)
:
    All chemical substances in this product comply with all applicable rules or order under TSCA.
SARA (Superfund Amendments and Reauthorization Act) Title III
    302 Extreme Hazardous Substance
:  None
    311/312 Hazard Classification
:  None
EU Information
       1999/45/EEC and 67/548/EEC
       Symbol & Indication
: Not required
  R-Phrase
:  Not  required
  76/769/EEC
: All chemical substances in this product comply with all
  applicable rules or order under 76/69/EEC.
16.  OTHER INFORMATION
NFPA  Rating  (USA)
: Health = 1
Flammability = 1   Reactivity = 0
WHMIS Legislation (Canada)
: This product is not a controlled product.
References
IARC (1998) : IARC monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Humans, Vol.
65, Printing Process And Printing Inks, Carbon Black and Some Nitro Compounds, Lyon, pp-
149-261 H. Muhle, B. Bellmann, O. Creutzenberg, C. Dasenbrock, H. Ernst, R. Kilpper,
J. C. MacKenzie, P. Morrow, U. Mohr, S. Takenaka, and R. Mermelstein (1991) Pul-
monary  Response to Toner upon Chronic Inhalation Exposure in Rats.  Fundamental
and Applied Toxicology 17, pp. 280-299.
The information of this data sheet represents our current data and best opinion as to the proper use in
handling of this product under normal conditions. However, all materials may present unknown hazards and
should be used with caution. Although certain hazards are described herein, we do not guarantee that these
are the only hazards which exist.
Page of 127
Display

Click on the first or last page to see other AL-1551 (serv.man10) service manuals if exist.