Unit Disassembly 
Center Rear Cover Removal  
 
 
 
 
Remove 6 machine 
screws (red) and lift off  
the VESA plate angle 
assembly. 
Remove 8 Machine 
screws from Center Rear 
Cover. 
 
31 
VESA Plate Angle 
Unit Disassembly 
T Cover Removal  
 
 
 
 
Remove  machine screws 
(red) and lift off  the T 
Cover. 
Remove 8 Machine 
screws from Center Rear 
Cover. 
 
32 
Rear View 
33 
 
IF PWB 
C-PWB 
Ultrasonic Receiver  
Camera Control PWB 
POWER PWB 
5 volt PS 
PWB 
AC 
Relay 
PWB 
USB RELAY PWB 
There are two USB ports, however, only one is usable by the customer.  Please 
be sure that the customer is using the USB port on the left (rear view) and on 
the right for front view. 
 
Please remove plate from left side of outside cabinet and re-stick to the right 
unusable USB jack.  
Troubleshooting 
Entering Service Menu 
PN-L702 shown for example 
 
 
 
 
Please follow these next steps on      
how to enter the service menu 
 
1.
 With the set powered on, press and 
hold the “SIZE” button on remote 
control until a green “F” appears on 
the left hand side of the screen.  
Next press BRIGHT-, VOL-, 
BRIGHT+, VOL+ in sequence on the 
remote control.  SERVICE MENU1 is 
now displayed. 
 
 
 
33.1 