CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L702B/L602B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 41
(2) AGC CONFIG, SCAN CONFIG
Default of AGC Config and Scan Config are decided to configuration file
(
3Refer to page 4 - 45 "(8) CHANGE CONFIGRATION".), but they
can be changed by pull-down.
1 ) AGC Config
Press [Check] button when item of “AGC Config” is “AGC -5db” or
“AGC -4db” or “AGC -2db” or “AGC 0db”. After AGC is fixed to
appropriate value, state of LED/Sensor is obtained.
Press [Check] button when item of “AGC Config” is “AGC AUTO”.
Press [Check] button when item of “AGC Config” is “AGC AUTO”.
The error of process check item is checked, and error information
is displayed if there is error, and after AGC is adjusted by the auto-
matic operation, state of LED/Sensor is obtained if there isn’t error.
matic operation, state of LED/Sensor is obtained if there isn’t error.
Press [Check] button when item of “AGC Config” is “Current”. State
of LED/Sensor is obtained without the change in AGC. Item of
“Current” can be switched to display (AGC_TEST=2) or nondisplay
“Current” can be switched to display (AGC_TEST=2) or nondisplay
(AGC_TEST=1) by “AGC_TEST” of configuration file (
3Refer to
page 4 - 45 "(8) CHANGE CONFIGRATION".). If it is
AGC_TEST=0, the change in item of “AGC Config” is impossible
AGC_TEST=0, the change in item of “AGC Config” is impossible
and configuration is always a setting of “Current”.
2 ) Scan Config
Invalid configration of short scan is done when item of “Scan Con-
fig” is changed to “NORMAL ONLY”, and it is taken back when item
of “Scan Config” is changed to “DEFAULT”.
of “Scan Config” is changed to “DEFAULT”.
9 Save File
Press [Save File] button, and the data dis-
played in Pwd order is saved to a file in CSV
format.
format.
F Exit
Press [Exit] button, and this tool is finished.
Display
Content
CASE OF UNDIVIDED
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L702B/L602B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 42
(3) AUTOMATIC ADJUSTMENT OF AGC
“(3)” and “(4)” explains the operation when [Check] is pressed. When
item of “AGC Config” isn’t “AGC AUTO”, look at “(4)” because process
of “(3)” isn’t done. When item of “AGC Config” is “AGC AUTO”, the error
of “(3)” isn’t done. When item of “AGC Config” is “AGC AUTO”, the error
is checked by the following five steps. Moreover, step which is checked
by all attenuators is executed in order of -5db, -4db, -2db, and 0db (Cor-
respond step is step3) and step4.).
respond step is step3) and step4.).
<PROCESS CHECK ITEM1 (AGC_FIXTEST)>
STEP1:
The error is put out if there is a sensor in specified attenuator
(*AGC_FIXTEST_ATTENUATOR_SETTING) that exceeds the accept-
able distance from average value of OFF value
able distance from average value of OFF value
(*AGC_FIXTEST_PD_OFF_RANGE).
STEP2:
The error is put out if there is a sensor in specified attenuator that is
smaller than Acceptable minimum value of DIFF value
smaller than Acceptable minimum value of DIFF value
(*AGC_FIXTEST_PD_DIFF_RANGE).
<PROCESS CHECK ITEM2 (AGC_RANGETEST)>
STEP3:
The error is put out if there is a sensor in either of attenuator that
exceeds the acceptable distance from average value of OFF value
exceeds the acceptable distance from average value of OFF value
(*AGC_RANGETEST_PD_OFF_RANGE).
STEP4:
The error is put out if there is a sensor in either of attenuator that is
smaller than Acceptable minimum value of DIFF value
(*AGC_RANGETEST_PD_DIFF_RANGE).
(*AGC_RANGETEST_PD_DIFF_RANGE).
STEP5:
The error is put out if there isn’t validity of DIFF value.
VALIDITY OF DIFF VALUE
Average DIFF value increases as the attenuator value increases until
attenuator value that is first attenuator whose average DIFF value isn’t
attenuator value that is first attenuator whose average DIFF value isn’t
less than Monotone increase limit value of DIFF
value(*AGC_RANGETEST_PD_DIFF_LINEAR_TH).
Average DIFF values is bigger than High gain side descent of DIFF
value (*AGC_RANGETEST_PD_DIFF_REVERSE_TH) after first atten-
value (*AGC_RANGETEST_PD_DIFF_REVERSE_TH) after first atten-
uator whose average DIFF value isn’t less than Monotone increase limit
value of DIFF value appears.
If error is detected from either of sensor or substrate, it doesn’t proceed
to the next step. All substrates are evaluated in the step where the error
to the next step. All substrates are evaluated in the step where the error
was detected. Moreover, if error is detected in a certain attenuator
value, it doesn’t proceed to the next attenuator value.
If there is no error in five steps of the above, AGC Configuration taken
back and process of “(4)” is done. If there is an error, information of
back and process of “(4)” is done. If there is an error, information of
error is displayed.
3Refer to page 4 - 43 "(5) DISPLAY INFORMATION OF ERROR".
3Refer to page 4 - 43 "(5) DISPLAY INFORMATION OF ERROR".
The variable shown by “ * ” can set configuration value.
3Refer to page 4 - 45 "(8) CHANGE CONFIGRATION".
3Refer to page 4 - 45 "(8) CHANGE CONFIGRATION".
(4) OBTAIN STATE OF LED/SENSOR
Diagnostic data is obtained, and the data is displayed in substrate order
and difference between ON value and OFF value order.
Moreover, Status, Service Information, and Result (OK: Green, NG:
Moreover, Status, Service Information, and Result (OK: Green, NG:
Red) are updated from obtained data.
If [Check] button is pressed when item of “AGC Config” is “AGC -5db” or
“AGC -4db” or “AGC -2db” or “AGC 0db”, the diagnosis is executed with
“AGC -4db” or “AGC -2db” or “AGC 0db”, the diagnosis is executed with
the AGC Configuration set to the appropriate fixed value.(AGC Configu-
ration is taken back after diagnostic.)
If item of “AGC Config” is “AGC AUTO”, attenuator values (0:-5db, 1:-
If item of “AGC Config” is “AGC AUTO”, attenuator values (0:-5db, 1:-
4db, 2:-2db, 3:0db) of each substrate in “Status” in addition.
DESCRIPTIONS OF PWB ORDER
DESCRIPTIONS OF LED DIFFERENCE ORDER
1 Area
LED PWB name
2 Point
LED location
3 LED
LED status
[(Description) Normal: OK, Abnormal: E01]
[(Description) Normal: OK, Abnormal: E01]
4 Sensor
Sensor status
[(Description) Normal: OK, Abnormal: E01]
[(Description) Normal: OK, Abnormal: E01]
5 ON
Sensor value with the LED on.
6 OFF
Difference between the sensor values with the
LED on and off.
7 DIFF
Difference between the sensor values with LED
on and off.
1 Area
LED PWB name
2 Point
LED location
3 Status
LED status
[(Description) Normal: OK, Abnormal: NG]
[(Description) Normal: OK, Abnormal: NG]
4 DIFF
Difference between the sensor values with LED
on and off.
on and off.
EXAMPLE OF DISPLAYING DIAGNOSTIC RESULT (AGC -2DB)
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L702B/L602B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 43
(5) DISPLAY INFORMATION OF ERROR
<WHEN THE ERROR IS DETECTED IN STEP 1 - 4>
Number of error step (ErrStep) and attenuator value (ATT) are dis-
played in “Status”. The error step is displayed in the substrate where
played in “Status”. The error step is displayed in the substrate where
the error is detected and “OK” is displayed in the substrate where the
error is not detected in the “ErrStep”. Attenuator value when the error is
detected is displayed in “ATT”.
detected is displayed in “ATT”.
The data in attenuator value when the error is detected is displayed in
Pwb order and LED Difference order. Moreover, the sensor where the
error was detected is displayed by the deficit.
error was detected is displayed by the deficit.
<WHEN THE ERROR IS DETECTED IN STEP 5>
Number of error step (ErrStep) is displayed in “Status”. The error step is
displayed in the substrate where the error is detected and “OK” is dis-
displayed in the substrate where the error is detected and “OK” is dis-
played in the substrate where the error is not detected in the “ErrStep”.
Average DIFF value in each substrate and each attenuator is displayed
in Pwd order.
in Pwd order.
EXAMPLE OF DISPLAYING DIAGNOSTIC RESULT (AGC AUTO)
EXAMPLE OF DISPLAY WHEN THERE IS ERROR IN STEP 2
EXAMPLE OF DISPLAY WHEN THERE IS ERROR IN STEP 5
CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L702B/L602B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
4 – 44
(6) JUDGMENT OF DIAGNOSTIC RESULT
The diagnostic result is judged on the condition of following 1, 2, 3,
4.
4.
n
When all conditions are OK
3Diagnostic result is OK.
n
When either of condition is NG
3Diagnostic result is NG
MEMO
n
If item of “AGC Config” isn’t “AGC AUTO”, Condition 1 is not
included in the judgment condition.
included in the judgment condition.
n
If “CheckMaxMin” in configuration file equal 0, condition 3 is not
included in the judgment condition.
3Refer to page 4 - 45 "(8) CHANGE CONFIGRATION".
3Refer to page 4 - 45 "(8) CHANGE CONFIGRATION".
n
If “CheckLEDSensor” in configuration file equal 0, condition 4 is
not included in the judgment condition.
3Refer to page 4 - 45 "(8) CHANGE CONFIGRATION".
not included in the judgment condition.
3Refer to page 4 - 45 "(8) CHANGE CONFIGRATION".
1 Judgment of AGC error
n
When the error isn’t detected in process of “(3)”
3OK
n
When the error isn’t detected in process of “(3)”
3NG
2 Judgment of difference between ON value and OFF value
n
When the difference between ON value and OFF value isn’t less than
the threshold
3OK
n
When the difference between ON value and OFF value is less than
the threshold
the threshold
3NG
(The threshold can be changed by configuration file.)
3 Judgment of minimum OFF value and maximum ON value
Judgment is OK if both of the following two conditions are filled, other-
wise Judgment is NG.
n
Minimum value of sensor value of LED OFF isn’t less than the thresh-
old of minimum.
n
Maximum value of sensor value of LED ON isn’t more than the
threshold of maximum.
threshold of maximum.
(The threshold of minimum and the threshold of maximum can be
changed by configuration file.)
4 Judgment of state of LED/Sensor
n
When the results of LED and Sensor are all OK
3OK
n
When there is E01 in the result of LED and Sensor
3NG
(7) SAVE DIAGNOSTIC DATA
When you want to save the displayed data to a file, press the [Save
File] button. The data is saved to a file in CSV format.
<WHEN THE AGC CHECK RESULT IS OK OR THE AGC
SETTING IS OTHER THAN “AGC AUTO”>
SETTING IS OTHER THAN “AGC AUTO”>
*
1
When the AGC setting is other than “AGC AUTO,” the AGC check is
always OK.
*
2
For the items from “Area” to “DIFF,” the diagnostic data of the dis-
play order of PWB’s are delimited with commas and displayed in
sequence.
For “Result,” the diagnostic result (OK or NG) of each sensor is
For “Result,” the diagnostic result (OK or NG) of each sensor is
displayed.
*
3
Since the Status information records the Status data, the ATT
item is not included when the AGC setting is other than “AGC
item is not included when the AGC setting is other than “AGC
AUTO.”
<WHEN AN ERROR OCCURS IN STEPS 1 - 4.>
*
1
In the parentheses () of “AGC Check,” the corresponding step
and the attenuator are displayed as shown above when the AGC
check result is NG.
*
2
The diagnostic result at the time of NG is displayed. (In the above
case, since “ATT0” is in the parantheses of AGCCheck,
“-5db” is displayed.)
*
3
The check result of each PWB for the corresponding step and
the attenuator of NG.
1
Saved file name
1
Status item
1
Status data
1
Data
(Diagnostic data delimited by
comma in order of display)
(Diagnostic data delimited by
comma in order of display)
1
AGC result and diagnostic result
1
Item Name
*2
*3
FILE FORMAT
D:\AllData.csv
AGCCheck=OK(---/---),Result=OK
Area,Point,LED,Sensor,ON,OFF,DIFF,Result
XA,01,OK,OK,134,051,083,OK
XA,02,OK,OK,130,051,079,OK
XA,03,OK,OK,131,052,079,OK
XA,04,OK,OK,132,052,080,OK
XA,05,OK,OK,124,052,072,OK
XA,06,OK,OK,128,052,076,OK
XA,07,OK,OK,124,052,072,OK
XA,08,OK,OK,129,052,077,OK
XA,09,OK,OK,123,052,071,OK
XA,10,OK,OK,123,051,072,OK
AGCCheck=OK(---/---),Result=OK
Area,Point,LED,Sensor,ON,OFF,DIFF,Result
XA,01,OK,OK,134,051,083,OK
XA,02,OK,OK,130,051,079,OK
XA,03,OK,OK,131,052,079,OK
XA,04,OK,OK,132,052,080,OK
XA,05,OK,OK,124,052,072,OK
XA,06,OK,OK,128,052,076,OK
XA,07,OK,OK,124,052,072,OK
XA,08,OK,OK,129,052,077,OK
XA,09,OK,OK,123,052,071,OK
XA,10,OK,OK,123,051,072,OK
㧦
YD,25,OK,OK,113,053,060,OK
YD,26,OK,OK,114,053,061,OK
YD,27,OK,OK,125,053,072,OK
YD,26,OK,OK,114,053,061,OK
YD,27,OK,OK,125,053,072,OK
Area,LED,Sensor,ATT
XA,OK,OK,1
XB,OK,OK,2
:
YD,OK,OK,1
XA,OK,OK,1
XB,OK,OK,2
:
YD,OK,OK,1
*1
1
The check result of each PWB
FILE FORMAT
D:\AllData.csv
AGCCheck=NG(Step2/ATT0),Result=NG
Area,Point,LED,Sensor,ON,OFF,DIFF,Result
XA,01,OK,OK,134,051,083,OK
XA,02,OK,OK,130,051,079,OK
XA,03,OK,OK,131,052,079,OK
XA,04,OK,OK,132,052,080,OK
XA,05,OK,OK,124,052,072,OK
XA,06,OK,OK,128,052,076,OK
XA,07,OK,OK,124,052,072,OK
XA,08,OK,OK,129,052,077,OK
XA,09,OK,OK,056,052,004,NG
XA,10,OK,OK,123,051,072,OK
:
YD,25,OK,OK,113,053,060,OK
YD,26,OK,OK,114,053,061,OK
YD,27,OK,OK,125,053,072,OK
AGCCheck=NG(Step2/ATT0),Result=NG
Area,Point,LED,Sensor,ON,OFF,DIFF,Result
XA,01,OK,OK,134,051,083,OK
XA,02,OK,OK,130,051,079,OK
XA,03,OK,OK,131,052,079,OK
XA,04,OK,OK,132,052,080,OK
XA,05,OK,OK,124,052,072,OK
XA,06,OK,OK,128,052,076,OK
XA,07,OK,OK,124,052,072,OK
XA,08,OK,OK,129,052,077,OK
XA,09,OK,OK,056,052,004,NG
XA,10,OK,OK,123,051,072,OK
:
YD,25,OK,OK,113,053,060,OK
YD,26,OK,OK,114,053,061,OK
YD,27,OK,OK,125,053,072,OK
Area, Result
XA,NG
XB,OK
:
YD,OK
XA,NG
XB,OK
:
YD,OK
1
Saved file name
1
Data
(Diagnostic data delimited by
comma in order of display)
(Diagnostic data delimited by
comma in order of display)
1
AGC result and diagnostic result
1
Item Name
*2
*1
*3