CHAPTER 4. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
PN-L702B/L602B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES
 4 – 49
22. NONDISCLOSURE SCREEN OF CONTROLLING THE MONITOR WITH PC (LAN) 
CAUTION
n
The screens described in this chapter are not open to the public. 
22 - 1. CUSTOM SETTING
For the custom setting, the following web access screen is provided. 
■ SMTP-AUTH SETTING
This screen is displayed when the following URL is accessed with a
web browser.
http://<IP Address>/custom_smtpauth.cgi
On this screen, the following item can be set.
 
■ ETHER SETTINGS
This screen is displayed when the following URL is accessed with a
web browser.
http://<IP Address>/custom_ether.cgi
On this screen, the following item can be set.
*
1
This is the factory setting.
22 - 2. SERVICE MENU
For the service menu, the following web access screen is provided.
This screen is displayed when the following URL is accessed with a
web browser.
http://<IP Address>/service.cgi
On this screen, the following item can be set.
Display when a command is sent from the edit box of “COMMAND”
When the command “POWR????” which reads the power status issent.
Example of the display when “1” (Power ON status) is sent back
from the display.
Item
Set value range, remark
SMTP-AUTH
Setting to determine whether SMTP-AUTH is
displayed or not in “MAIL” - “ORIGNATOR-
AUTHENTICATION”.
The factory setting is “OFF”
Item
Set value range, remark
MODE
The communication speed of LAN is selected 
from the following options:
n
Auto (Automatic setting) 
*1
n
100M Full
n
100M Half
n
10M Full
n
10M Half
SMTP PORT
The port number of SMTP is set.
The default is “0”.
In this case, Port No. 25 is used.
If the port number of the SMTP server is other 
than 25, make this setting. 
 
Item
Set value range, remark
COMMAND
When [Send] button is clicked, the RS-232C 
command entered to the edit box by the user 
is sent to this machine.
The response of the command is displayed in 
the lower section of the edit box. 
SYSTEM LOG
The system log file of this machine is
obtained. 
When the anchor is clicked, the file download 
dialogue of the browser is displayed.
Follow the instructions of the dialogue.
TEMPERATURE 
LOG
The temperature log file of this machine is 
obtained.
When the anchor is clicked, the file download 
dialogue of the browser is displayed. Follow 
the instructions of the dialogue.
PN-L702B/L602B FIRMWARE UPDATA PROCEDURES/EDID WRITING PROCEDURES
 5 – 1
CHAPTER 5.  FIRMWARE UPDATA PROCEDURES/EDID WRITING 
PROCEDURES
There are two kinds of firmware provided in this model. When upgrading the firmware, first upgrade the main firmware (1. MAIN FIRMWARE
UPDATE PROCEDURE), second upgrade the LAN firmware (2. LAN FIRMWARE UPDATE PROCEDURE) in this sequence.
1. MAIN FIRMWARE UPDATE PROCEDURE
1 - 1. OPERATING CONDITIONS OF FIRMWARE UPDATE
The operating conditions for firmware update of the information display
are as follows.
*
1
Very occasionally it takes more time to write  the firmware.
The RS-232C cable required for update is as follows. Connect the COM
port of PC and the RS-232C input terminal of the display with the cable. 
OS
(32bit only)
n
Windows XP
n
Windows Vista
*1
n
Windows 7 
*1
Communication 
port
RS-232C port recognized as a COM port
(Which allows communication in 115Kbps.)
RS-232C cable
Straight cable (D-SUB 9pin female - female)
RS-232C input 
terminal
RS-232 straight cable
(commercially available)
To COM port
PC
CHAPTER 5. FIRMWARE UPDATA PROCEDURES/EDID WRITING PROCEDURES
PN-L702B/L602B FIRMWARE UPDATA PROCEDURES/EDID WRITING PROCEDURES
 5 – 2
1 - 2. FIRMWARE UPDATE
1 ) Press [Main Firmware] button of the Service Tool Launcher, and the
updater starts up.
2 ) Select the COM port to be used for communication. 
(“COM1” on the above screen)
3 ) Set the batch file name as “.\isp_spi_ext_PNEXXX.txt”. 
(It is set as the default. Do not change it.)
4 ) Press [BATCH] button, and the firmware writing is started. 
For about 3 minutes and writing is completed. When “Firmware
version up completed” is displayed, the firmware update is com-
pleted.
MEMO
n
Very occasionally it takes about 8 minutes to write the firmware
on Windows Vista or Windows 7.
After completion of upgrading the firmware, the monitor is self-reset
and the new version of firmware starts running.
5 ) If the [BATCH] button is pressed with other than this model con-
nected, the message “ERROR !!! “Wrong Model Type”” is dis-
played. In this case, please check the model of the connected
monitor.
■ WHEN UPDATING IS FAILED
First, turn OFF the main power and then turn it ON again. Then, press
[BATCH2] button to start writing the firmware. (Don’t press [BATCH3].)
In about 4 minutes, updating is completed and “Firmware update com-
pleted” is displayed. It is the end of firmware updating. 
MEMO
n
Very occasionally it takes about 8 minutes to write the firmware
on Windows Vista or Windows 7. 
After completion of upgrading the firmware, the monitor is self-reset and
the new version of firmware starts running.
CHAPTER 5. FIRMWARE UPDATA PROCEDURES/EDID WRITING PROCEDURES
PN-L702B/L602B FIRMWARE UPDATA PROCEDURES/EDID WRITING PROCEDURES
 5 – 3
1 - 3. VERSION CHECK PROCEDURES
■ CHECK METHOD BY THE FIRMWARE 
UPDATER
The current firmware version can be checked by pressing [VERSION]
button when the monitor power lamp is lighted in green.
The check sum can be also checked by pressing [CHECK SUM] button
similarly.
■ CHECK METHOD BY THE SERVICE MENU
With an image displayed on the screen, use the remote controller to dis-
play the SERVICE MENU1 screen. Check the firmware version.
(FIRM VERSION (MAIN)).
To display SERVICE MENU1, press and hold [SIZE] of the remote control
(for 5 seconds or more), and then press the button of [BRIGHT- ( 
1 )],
[VOL- ( 
4 )], [BRIGHT+ ( 3 )] and  [VOL+ ( 2 )] sequentially.
After confirming the version, press the [MENU] button of the remote
control to close the SERVICE MENU1 window.
SERVICE1
SERVICE2
SERVICE3
MODEL
S/N
SERVICE MENU1
FIRM VERSION (MAIN)
CHECK SUM (MAIN) 
1/1
: PN-XXXX
: XXXXXXXX
: OK Ver 1.00 (110801)
: OK 1234ABCDEF
ADJUSTMENT CHECK
: W/B CALIB
USAGE TIME
: 999999H
END
̖[MENU]
DISPLAY
SERVICE1
SERVICE2
SERVICE3
MODEL
S/N
SERVICE MENU1
FIRM VERSION (MAIN)
CHECK SUM (MAIN) 
FIRM VERSION (SUB)
CHECK SUM (SUB)
USAGE TIME
1/1
: PN-XXXX
: XXXXXXXX
: OK Ver 1.00 (110801)
: OK 1234ABCDEF
: OK Ver 1.00 (110801)
: OK 1234ABCD
: 999999H
END
̖[MENU]
ADJUSTMENT CHECK
: W/B CALIB
DISPLAY + EXPANSION BOARD
Page of 127