DOWNLOAD Sharp UP-3515 (serv.man11) Service Manual ↓ Size: 1.31 MB | Pages: 41 in PDF or view online for FREE

Model
UP-3515 (serv.man11)
Pages
41
Size
1.31 MB
Type
PDF
Document
Driver / Update
Brand
Device
EPOS / UP-3500 UP-3515 Enhancement Version 1.67 Programming and Operation Manual and revision history
File
up-3515-sm11.pdf
Date

Sharp UP-3515 (serv.man11) Driver / Update ▷ View online

 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
New functions 
 
Doc: up35xx_pm_e_1v67 
 
Page 9 / 41 
Parts & Technical Services
6.
 
VAT ID program parameter 
In certain countries, it is mandatory to program a unique VAT ID number at the ECR. To fulfil this 
fiscal legislation, a new programming possibility is available at: 
\6 PGM2 MODE\2 SETTING\8 TERMINAL. 
Example according to Norwegian law: NO 123 456 789 MVA 
The texts “NO” and “MVA” are fixed. For these texts, two new function texts are available and can 
be translated by the Text Converter Tool. 
The number is freely settable and is of 9 digits numeric type. 
The text and the number will be concatenated and printed left aligned. 
Examples with 3 digits for VAT ID number: 
NO 000 000 123 MVA 
Examples with 9 digits for VAT ID number: 
NO 123 456 789 MVA 
The VAT ID number will be printed on every registration as well as on General Report. 
Remark: The VAT ID is available in Norway and Netherland fiscal mode only. 
Programming and Print samples 
 
 
Norway 
 
 
 
 
 
 
Netherland 
 
With other country-setting the bill-number can be set here. 
 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
New functions 
 
Doc: up35xx_pm_e_1v67 
 
Page 10 / 41 
Parts & Technical Services
7.
 
Carry out of “Saved Reports on SD Card” manually 
At V1.50 the feature “Saved Reports on SD Card” has been introduced. With this feature it 
becomes possible to save secure data files on the SD Card controlled by a scheduler. 
Since this new version V1.60, it is also possible to start the saving of the secure data files manually. 
To enable this functionality, the SRV parameter #992B +4 has to be set accordingly and the key 
“EOD_READY_CHECK” must be available on a screen. 
In order to start the saving, the code ‘4682’ must be entered prior to pressing of the 
“EOD_READY_CHECK” key. 
 
Carry out of “Saved 
Reports on SD Card” 
manually 
Register item with fractional 
quantity if Mix&Match is set 
Save&Clear EJ on SD Card 
after Gen. Z 
#992-B 
Default 
No 
No 
No 
 
Yes 
 
Yes 
No 
 
Yes 
 
Yes 
No 
No 
 
Yes 
 
Yes 
No 
 
Yes 
 
 
8.
 
Register item with fractional quantity if Mix&Match is set 
If a Mix&Match condition has been set, a registration of an item with fractional quantity is 
impossible. By setting the new SRV parameter #992B +2 it will be possible to make a registration of 
such kind of item, but items with fractional quantity will not be considered for the Mix&Match 
calculation. 
 
Carry out of “Saved 
Reports on SD Card” 
manually 
Register item with fractional 
quantity if Mix&Match is set 
Save&Clear EJ on SD Card 
after Gen. Z 
#992-B 
Default 
No 
No 
No 
 
Yes 
 
Yes 
No 
 
Yes 
 
Yes 
No 
No 
 
Yes 
 
Yes 
No 
 
Yes 
 
 
 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
New functions 
 
Doc: up35xx_pm_e_1v67 
 
Page 11 / 41 
Parts & Technical Services
9.
 
50 Øre Exists / Not exists for Norwegian rounding system 
This is a special mode for the Norwegian rounding system. it is possible to set:  
“50 Øre    Exists / Not exists”  
In: 
”\6 PGM2 MODE\2 SETTING\10 OPTIONAL\2 FUNCTION SELECT1”  
This new PGM parameter becomes valid if the already existing SRV parameter #901C is set to 
“Sweden” (+1). 
Please refer to below mentioned table in order to get an overview over the different rounding 
systems: 
 
SRV #901C +1 (50 ØRE rounding valid) and 
PGM2 50 ØRE: EXISTS 
SRV #901C +1 (50 ØRE rounding valid) and 
PGM2 50 ØRE: NOT EXISTS 
1. Payment Amount rounding of the lowest 2 digits 
00 – 24 = Rounding down 
25 – 74 = 50 
75 – 99 = Rounding up 
 
Rounding is done for: 
Subtotal 
Differ-Subtotal 
All payments 
Domestic currency amount at Exchange function 
Item amount in case of S/D receipt type 
1. Payment Amount rounding of the lowest 2 digits 
00 – 49 = Rounding down 
50 – 99 = Rounding up 
 
 
Rounding is done for: 
Subtotal 
Differ-Subtotal 
All payments 
Domestic currency amount at Exchange function 
Item amount in case of S/D receipt type 
2. Tender amount entry check 
When the lowest 2 digits are not “00” or “50” an  
error occurs at: 
CASH payment 
CHECK payment 
CREDIT payment 
RA entry 
PO entry 
SCM(+) / SCM(-) entry 
CCD entry 
2. Tender amount entry check 
When the lowest 2 digits are not “00” an error 
occurs at: 
CASH payment 
CHECK payment 
CREDIT payment 
RA entry 
PO entry 
SCM(+) / SCM(-) entry 
CCD entry 
3. Item price and amount are not rounded 
3. Item price and amount are not rounded  
4. A price entry for an item can be another one  
than lowest 2 digits of “00 / 50” 
4. A price entry for an item can be another one  
than lowest 2 digits of “00” 
5. Taxable Subtotal / VAT are not rounded 
5. Taxable Subtotal / VAT are not rounded 
6. ORDER Total – PAID Total  
Order total is updated before amount rounding 
Paid total is updated after amount rounding 
O-P includes a difference amount 
6. ORDER Total – PAID Total  
Order total is updated before amount rounding 
Paid total is updated after amount rounding 
O-P includes a difference amount 
 
 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
New functions 
 
Doc: up35xx_pm_e_1v67 
 
Page 12 / 41 
Parts & Technical Services
10.
 
Additional Information 
In order to get the General Z Report written into the EJ while using the SAVED REPORTS feature, it 
must be ensured to set the parameter “PRINT GEN.REPORT” to “YES”. 
”\6 PGM2 MODE\2 SETTING\11 REPORT\8 SAVED REPORTS”  
Whenever a fiscal mode is set, the setting of the SRV parameter #986D (-1 no recording of 
J/EJ/TLOG in TRAINING MODE) is regardless. In fiscal mode every activity also of a Training Clerk will 
be recorded. 
 
11.
 
Extension of PLU-Info Text [V1.62] 
The previous specification of 10 lines with each 30 characters for 
the PLU INFO text was not sufficient. This has been extended in V 
1.62 again. 
In  
\SRV MODE\2 SETTING\10 FILE\4 PLU TABLES 
there is a new input syntax for the available capacity 
for the PLU INFO text. 
The value in the first field specifies of how many PLU INFO texts can 
be created in general. The value in the second field defines of how 
many lines for all PLU INFO texts are available in total. Each line can 
hold up to 30 characters. 
The available total lines are shared by the number of created PLU INFO texts. According to the right 
example, 50 PLU INFO texts can be created with in total 1000 lines. 
In an inline system, this file has to be created at every machine 
As known from the previous version, the PLU INFO text can be displayed or printed. If there is a line 
with only a minus character (-) in it, the print out of the text will be done up to this line. All the 
lines which are beyond this “-“ line are only visible on the info screen. 
Example: 
Display of PLU INFO text 
 
 
print out of PLU INFO text 
 
 
 
 
 
Page of 41
Display

Click on the first or last page to see other UP-3515 (serv.man11) service manuals if exist.