DOWNLOAD Sharp UP-3515 (serv.man11) Service Manual ↓ Size: 1.31 MB | Pages: 41 in PDF or view online for FREE

Model
UP-3515 (serv.man11)
Pages
41
Size
1.31 MB
Type
PDF
Document
Driver / Update
Brand
Device
EPOS / UP-3500 UP-3515 Enhancement Version 1.67 Programming and Operation Manual and revision history
File
up-3515-sm11.pdf
Date

Sharp UP-3515 (serv.man11) Driver / Update ▷ View online

 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
New functions 
 
Doc: up35xx_pm_e_1v67 
 
Page 13 / 41 
Parts & Technical Services
12.
 
Employee Time In/Out with contactless Clerk Key only [V1.64] 
It has been requested that the Employee Time In/Out should only be possible by using a contactless 
Clerk Key. By setting the SRV parameter #992C +4 this feature becomes available with V1.64. 
Because only a 4 digit number can be assigned during the programming of the contactless Clerk 
Key, the Employee code has to follow this restriction and must not exceed 9999. On the other 
hand, all Clerks related functions are not possible anymore. The contactless Clerk Key can be used 
for Time In/Out only. 
 
Contactless Clerk Key for 
Employee Time In/Out 
 
 
#992-C 
Default 
No 
 
 
 
 
 
 
 
 
 
 
Yes 
 
 
 
 
 
 
 
 
 
 
 
13.
 
Combo PLU to Drink Dispenser [V1.65] 
In the previous version, only PLU and Link PLU registrations were sent to the Drink Dispenser.  
Since V1.65 even a Combo PLU registration will be sent to the Drink Dispenser. All combo items, 
leading Combo as well as the tied Combo PLUs, will be sent, if their numbering corresponds to the 
Drink Dispenser value number range. This feature is enabled by default. 
 
14.
 
Scale registration without Tara [V1.65] 
If a tare weight has been set at the scale, it will be overwritten by the information sent from the 
ECR if there is no tare table assigned at the ECR for that PLU. 
In this case, the ECR simply sends 0 as the tare weight. To avoid this, the ECR will send the data 
without any tare information whenever there is no tare table assigned to that PLU and no manual 
Tara-entry has been done. 
This new behaviour is valid since V1.65. 
 
 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
New functions 
 
Doc: up35xx_pm_e_1v67 
 
Page 14 / 41 
Parts & Technical Services
15.
 
Screen limitation [V1.65] 
For each Clerk a screen limitation can be set in order to disable the access to certain screens. This is 
current specification. But in case no clerk is signed on, every screen can be displayed without any 
limitation. 
To make it possible, to have a screen which can be shown only to signed-on clerks a new SRV 
parameter (SRV #992D) has been introduced. If this SRV parameter is set the screen# 30 can only 
be opened if a clerk is signed on and has no limitation.  
If the clerk is signed on, the above mentioned screen limitation setting becomes valid. 
 
Contactless Clerk Key for 
Employee Time In/Out 
 
Display screen #30 only if 
a clerk is signed on. 
#992-C 
Default 
No 
 
No 
 
Yes 
 
 
No 
 
Yes 
 
Yes 
 
No 
 
Yes 
 
 
No 
 
Yes 
 
 
16.
 
Customer charge limit [V1.65] 
Currently the Customer charge limit will be validated by every single item registration. Even if the 
Customer wants to pay by Cash, it can happen that the registration is not possible because it 
exceeds the set Customer limit. 
If the already existing SRV parameter #986A is set to -4 (Customer code entry finalized by -> Any 
Payment) the Customer limit will be validated only at the end of the transaction by using CHARGE. 
 
17.
 
Sending of registration data to the Ethernet network [V1.67] 
In order to use a PC as e.g. a customer display or as a video surveillance system (with corresponding 
software) it is possible to send out registration data over the Ethernet network. During a 
registration, every single item registration will be send. After finalizing the registration, the total 
amount as well as the clerk name and number will be sent additionally. 
To activate this feature the new Service parameter #997 has to be set accordingly. With this 
parameter the last octet of the IP address of the Server PC as well as the port the Server PC is 
listening to must be defined. 
 
Listening Port of Server PC 
Port &HFEED + X 
Last octet of IP address of Server PC 
#997 
Default 
000 
0000 
 
 
Prior to set the corresponding SRV parameter, a proper working Inline System has to be setup. Also 
the MWS at \6 PGM2 MODE\2 SETTING\23 MWS CONFIG\[IP ADDRESS1-4] must set to the same 
network. After setting this SRV parameter #997 a Service Reset is necessary. 
For transmitting the data, the UDP protocol will be used, means the ECR does not expect any 
answer from the Server PC. 
 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
Changes / Improvements / Corrections since V1.60/V1.61 
 
Doc: up35xx_pm_e_1v67 
 
Page 15 / 41 
Parts & Technical Services
  >>> Changes / Improvements / Corrections since V1.60 <<< 
C 0
 
Wrong amount calculation for an item which has been split during B.S. Item 
C 0.1
The amount calculation for an item which has been split by Split key during B.S. Item operation was 
wrong. This is corrected with V1.60. 
 
  >>> Changes / Improvements / Corrections since V1.61 <<< 
C 1
 
New Model name 
C 1.1
Since V1.61 the model name has been changed from UP-3500V to 
UP-35xxV.  
 
 
 
 
This model name is visible in the System bar as well as in the ROM 
Version print out. 
 
 
Function Texts using same memory 
C 1.2
The function texts #160 ‘OVER.COST’ and #251 ‘OPEN ROOM’ were using the same memory. In 
case of changing the text for one of them, it results in changing the text for both at the same time. 
This is corrected since version V1.61. 
 
 
Missing receipts in the Electronic Journal 
C 1.3
If a bill print has been performed after a registration, the related receipt was not written into the 
Electronic Journal by mistake. With version V1.61, the receipt and the bill are written into the 
Electronic Journal. 
 
 
Saved Reports Folder Name 
C 1.4
It could happen that a broken folder name is shown in PGM2 programming mode in case a folder 
name with 8 characters has been set. Refer to: 
\6 PGM2 MODE\2 SETTING\11 REPORT\8 SAVED REPORTS\[FOLDER NAME] 
This is corrected since version V1.61. 
 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
Changes / Improvements / Corrections since V1.60/V1.61 
 
Doc: up35xx_pm_e_1v67 
 
Page 16 / 41 
Parts & Technical Services
 
Saved Reports in Inline-System 
C 1.5
Because the reports in an Inline-System will be taken at the Master, the “Saved Reports” feature 
introduced at V1.50, is advisable at the Master only. The “Saved Reports” feature was not available 
at the Satellite. 
Besides of the main function of the “Saved Reports” feature, it is also possible to get e.g. the 
Electronic Journal data saved onto the SD Card. Since it is not possible to receive and store the 
Electronic Journal data from a Satellite at Master side, the “Saved Reports” feature is now available 
at the Satellite as well. 
If the “Saved Reports” feature is enabled at the Satellite it will save the Electronic Journal data and 
the All RAM Backup respectively the PGM Backup according to their PGM setting onto the local SD 
Card. 
Furthermore the function key “EOD_READY_CHECK” is also enabled at the Satellite in order to 
check if the machine is in a status that the “Saved Reports” can be carried out. 
 
 
Online function (Clerk Z-Report) in relation to the ECR status 
C 1.6
Some Online functionality depends on the status of the ECR, of course. For example if a Z-Report 
has to be taken over night and a Clerk forgot to finalize his transaction, the communication was 
not possible. This has been changed with V1.22 already. 
Due to some fiscal legislation, this subject again has become a matter of change. 
Whenever a Z-Report is carried out via Online functionality but a Clerk forgot to finalize his 
transaction, this transaction will be forced to finalize and the transaction amount will be stored in 
the CREDIT9 (OPEN RCPT) totalizer. It is regardless if the open transaction remained in the 
foreground or in the background. e.g. in case of overlapped clerk function. Such kind of closed 
receipts will neither be recorded into the Electronic Journal nor will they update the TAX totalizers. 
 
 
Bill-Separation-Error 
C 1.7
Sometimes Bill-separation results in separated items with ZERO-prices. 
This problem has been solved with V1.61. 
 
Page of 41
Display