DOWNLOAD Sharp UP-3515 (serv.man11) Service Manual ↓ Size: 1.31 MB | Pages: 41 in PDF or view online for FREE

Model
UP-3515 (serv.man11)
Pages
41
Size
1.31 MB
Type
PDF
Document
Driver / Update
Brand
Device
EPOS / UP-3500 UP-3515 Enhancement Version 1.67 Programming and Operation Manual and revision history
File
up-3515-sm11.pdf
Date

Sharp UP-3515 (serv.man11) Driver / Update ▷ View online

 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
Compatibility 
 
Doc: up35xx_pm_e_1v67 
 
Page 5 / 41 
Parts & Technical Services
0.
 
Compatibility 
The ROM version V1.60 is based on V1.51, but it is not compatible (neither Data nor Language 
Text Resources) with this ROM version. 
Due to changes in the memory structure, it is necessary to carry out the Master Reset with the 
dealer password (13974682) after the ROM Version update has been done. 
Important note: 
In order to comply with legal regulations in several European countries, the counting and Journal 
print/EJ storage of all carried out actions is necessary. 
Beside of the above mentioned, it is also necessary to set certain parameters to a default value 
during the setup procedure of the machine according to the requirements of the individual country 
law. 
If these parameters have been set once, they cannot be changed afterwards anymore (except by 
making a Master Reset again). Also a change by Online function or loading of Programming Data 
from SD Card is prohibited. 
 
0.1.
 
Caution V1.61 – V1.61 is not compatible with V1.60 
Caution V1.61: The ROM version V1.61 is based on V1.60, but it is not compatible (neither Data 
nor Language Text Resources) with this ROM version. 
0.2.
 
Caution V1.62 – V1.62 is not compatible with V1.61 
Caution V1.62: The ROM version V1.62 is based on V1.61, but it is not compatible (neither Data 
nor Language Text Resources) with this ROM version. 
There exist two different ROM Versions. One is dedicated for the UP-3500 while the second one is 
dedicated for the UP-3515. Both ROM Versions are “ALL RAM” compatible, by means an “ALL 
RAM” backup from the UP-3500 can be loaded into the UP-3515 or vice versa. 
0.3.
 
Note V1.63 – V1.63 is fully compatible with V1.62 
Note V1.63: The ROM version V1.63 is based on V1.62, and is fully compatible (Data and 
Language Text Resources) with this ROM version. 
0.4.
 
Note V1.64 – V1.64 is fully compatible with V1.63 
Note V1.64: The ROM version V1.64 is based on V1.63, and is fully compatible (Data and 
Language Text Resources) with this ROM version. 
0.5.
 
Note V1.65 – V1.65 is fully compatible with V1.64 
Note V1.65: The ROM version V1.65 is based on V1.64, and is fully compatible (Data and 
Language Text Resources) with this ROM version. 
0.6.
 
Note V1.66 – V1.66 is not fully compatible with V1.65 
Note V1.66: The ROM version V1.66 is based on V1.65, but is not fully compatible with this 
ROM version. Data is fully compatible but Language Text Resources not. 
0.7.
 
Note V1.67 – V1.67 is fully compatible with V1.66 
Note V1.67: The ROM version V1.67 is based on V1.66, and is fully compatible (Data and 
Language Text Resources) with this ROM version. 
 
 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
New functions 
 
Doc: up35xx_pm_e_1v67 
 
Page 6 / 41 
Parts & Technical Services
1.
 
New Master Reset procedure 
A new Master Reset procedure is available in order to set the ECR into the correct country mode 
during the setup phase. 
It is possible to setup the ECR easy and user friendly according to the country specific fiscal 
legislations. To keep this, it is prohibited to change the fiscal related setting after the ECR has been 
setup. Once fiscal setting has been done, it can be reset by Master Reset only. The fiscal related 
parameters can also not be changed afterwards anymore by using the online function or loading of 
Programming Data from SD Card. 
By carrying out a MRS Job, certain parameters as well as some text translation will be set 
automatically. Furthermore, all sales data are reset as follows: 
- Sales data including GT 
- Counters (Z Counter, Consecutive Number, Transaction Counter) 
- Some programming restrictions will be set accordingly. 
Without carrying out the country related fiscal job, the ECR keeps the original specification. 
In order to identify the country selected during the Master Reset procedure it will be displayed in 
the Status Bar.  
 
Furthermore, the chosen Fiscal Mode will be printed on the print out of 
\6 PGM2 MODE\1 READING\49 ROM VERSION 
 
 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
New functions 
 
Doc: up35xx_pm_e_1v67 
 
Page 7 / 41 
Parts & Technical Services
2.
 
European Fiscal Electronic Journal 
It must be possible to activate the Fiscal Electronic Journal even no country has been selected by the 
Master Reset procedure. With the new SRV parameter (#992A +4), the enhanced Fiscal EJ will be 
activated without setting some country related restriction. 
 
Activate 
European Fiscal 
Electronic Journal 
Grant M&M discount in  
Employee –Sales –Cons. 
Grant M&M discount in  
Credit Customer –Sales 
#992-A 
Default 
No 
No 
Yes 
 
No  
 
Yes 
Yes 
 
No  
 
Yes 
No 
Yes 
 
No  
 
Yes 
Yes 
 
No  
 
 
3.
 
Default setting of the Report formats 
In certain Report formats, some settings have been fixed according to the country selection during 
the setup phase. The grayed-out parameters are fixed and cannot be set anymore. Please refer to 
below mentioned picture as an example. 
 
 
4.
 
Checksum print on General Z Report 
To protect the written EJ data against manipulation a checksum will be used. 
The checksum is a 40 digits hexadecimal number and security algorithm will be used for its 
calculation. 
The calculated checksum is printed directly below the General Z-Report and is also written into the 
EJ. The calculated checksum is always printed in Fiscal mode. It is not printed on other reports than 
the General Z. Print format of the checksum is two lines. Example: 
0A121B0A-121B0A12-1B0A121B 
0A121B0A-121B0A12 
 
 
UP-3500/3515 
 
 
Manual – V1.6x
 
 
New functions 
 
Doc: up35xx_pm_e_1v67 
 
Page 8 / 41 
Parts & Technical Services
5.
 
Save&Clear of the EJ onto SD Card after Gen. Z Report automatically 
A new SRV parameter (#992B +1) is available now, in order to distinguish to make Save&Clear of 
the EJ onto SD Card automatically or not after the General Z-Report has been carried out. 
If the SRV parameter is set and the General Z-Report is selected, 
\2 X1/Z1 MODE\2 RESETTING\1 GENERAL  
the ECR is proofing if an SD Card is inserted, if the SD card is writeable and if the selected folder is 
available prior to the Z-Report. 
If one of these conditions is not met, a popup window with two buttons will show a related 
message. One button is for cancelling the report, while by pressing on the other button, the ECR 
will carry out the General Z-Report without Save&Clear the EJ onto SD Card. If the proofing result is 
positive, the Z-Report is carried out and the EJ will be erased after it has been written onto SD 
Card. The EJ Save&Clear job will be written into the next EJ. 
If any of the Fiscal Mode is selected, the SD Card jobs 
SRV MODE \ 7 SD CARD MODE \ 1 SAVING \ 1 SAVE ONLY \ 2 EJ DATA 
PGM MODE \ 8 SD CARD MODE \ 1 SAVING \ 1 SAVE ONLY \ 2 EJ DATA 
are disabled. Background is, to avoid that multiple EJ sales data is available which makes an 
integrity check of these sales data against the Z-Report very difficult. 
Remark: 
Using an Auto-Key for making the General Z-Report and Save&Clear of the EJ will not work in case 
of CCD entry is set to compulsory for this report. 
Also in an Inline-System, the individual General Z-Report must be carried out in order to get the 
report and to write the data onto SD Card. After the individual General Z-Report has been carried 
out, this individual machine locks until the consolidated report has been made at the Master. 
 
Carry out of “Saved 
Reports on SD Card” 
manually 
Register item with fractional 
quantity if Mix&Match is set 
Save&Clear EJ on SD Card 
after Gen. Z 
#992-B 
Default 
No 
No 
No 
 
Yes 
 
Yes 
No 
 
Yes 
 
Yes 
No 
No 
 
Yes 
 
Yes 
No 
 
Yes 
 
 
Page of 41