Sharp UP-3301 (serv.man4) Service Manual ▷ View online
UP-3301V
Built-in Printer: UP-T80BP
– 11 –
13. Connect the Printer cables to the CONTROL PWB.
1) SWITCH UNIT CABLE
I
: Connect to the CN7.
3) AUTO CUTTER RELAY PWB CABLE
L
: Connect to the CN4.
4) MOTOR CABLE
Q
: Connect to the CN2.
5) SENSOR CABLE
R
: Connect to the CN6.
6) I/F CABLE
8
: Attach the Ferrite core
[
.
Fig. 8
14. Routing for each cables as shown below
Fig. 9
15. Install the BOTTOM PLATE
2
2
2
2
.
Fig. 10
16. Install the PRINTER COVER
Y
Y
Y
Y
.
Fig. 11
2) HEAD CABLE
O
: Connect to the CN5.
Attach the FERRITE CORE
V
and CABLE
CLAMP
4
.
Fix the CABLE CLAMP
4
with a SCREW
X
.
26
22
13
21
16
19
4
28
: XEBSD30P08000
28
26
31
22
13
21
16
19
27
28
8
2
1
29
UP-3301V
LAN
– 12 –
1. LIST FOR SCREWs
2. INSTALLATION OF THE PAPER NEAR END SENSOR
[PARTS LIST]
1) Remove the BOTTOM PLATE .
2) Remove the PS+CONTROL PWB .
3) Solder the CONNECTOR
1
to the PS+CONTROL PWB (No. CN1)
4) Install the NEAR END SENSOR UNIT
3
to the CABINET , and fix it
with the fixing SCREW
2
.
Fig. 12
19. LAN
• The LAN connection is standard using a RJ45 connector.
20. RS232 I/F: STANDARD
1) Connect the RS232 cable
1
to the desired connector.
2) Install the ferrite Core
2
to every RS232 cable installed.
No.
PARTS CODE
M [mm]
L [mm]
K
XEBSD30P08000
3
8
Z
X
X
S
-
a
XEBSD26P06000
2.6
6
S
-
b
S
-
c
XEBSD26P08000
2.6
8
S
-
d
7
XEBSD30P06000
3
8
U
No.
PARTS NAME
PARTS CODE
NOTE
1
PAPER NEAR
END SENSOR
END SENSOR
DUNTK3819BHZZ
SENSOR UNIT,
FIXING SCREW
FIXING SCREW
2
NEAR END
SENSOR
CONNECTOR
SENSOR
CONNECTOR
QCNCM6865RC0B
2 pin connector
L
M
L
M
1
3
2
3cm
RCORF6699BHZZ
1
2
UP-3301V
CONTACTLESS KEY
– 13 –
21. CONTACTLESS KEY
1) Remove the connector of a clerk key
1
, Remove the two screws
2
, and remove the clerk key unit.
Remove the screw
3
and remove the clerk key.
2) Attach the contactless key to the plate. Attach the contactless key
unit to the upper cabinet with screws
2
, and set the connector
3
.
Attach the upper cabinet, attach the lid
4
, and attach the cap
5
tightly.
Note: The peojection
A
side of the lid
4
should be upper side.
■
■
■
■
Contactless key label
■
Attachment
HZ-R01CK
Note: In case contactless key attaches, be sure to attach CE-Mark label
(accessories) to a bottom cabinet.
Using contactless key of the product with which CE-Mark is not
attached is forbidden by law.
attached is forbidden by law.
Refer to the following figure for the attachment position of CE-Mark.
1
2
3
4
5
1
2
3
A
Key label
Key
Key label size
2.7
12
R9.5
0
-0.5
-0.5
0
-0.5
CE-MARK LABEL
25mm
q
SHARP CORPORATION
Digital Document Systems Group
Products Quality Assurance Department
Yamatokoriyama, Nara 639-1186, Japan
Digital Document Systems Group
Products Quality Assurance Department
Yamatokoriyama, Nara 639-1186, Japan
2003 July Printed in Japan
t
2003 BY SHARP CORPORATION
All rights reserved.