DOWNLOAD Sharp UP-3301 (serv.man4) Service Manual ↓ Size: 902.47 KB | Pages: 16 in PDF or view online for FREE

Model
UP-3301 (serv.man4)
Pages
16
Size
902.47 KB
Type
PDF
Document
Service Manual
Brand
Device
EPOS / Installation Manual (Version B Above)
File
up-3301-sm4.pdf
Date

Sharp UP-3301 (serv.man4) Service Manual ▷ View online

UP-3301V
Built-in Printer: UP-T80BP
– 11 –
13. Connect the Printer cables to the CONTROL PWB.
1) SWITCH UNIT CABLE 
I
: Connect to the CN7.
3) AUTO CUTTER RELAY PWB CABLE 
L
: Connect to the CN4.
4) MOTOR CABLE 
Q
: Connect to the CN2.
5) SENSOR CABLE 
R
: Connect to the CN6.
6) I/F CABLE 
8
: Attach the Ferrite core 
[
.
Fig. 8
14. Routing for each cables as shown below
Fig. 9
15. Install the BOTTOM PLATE 
2
2
2
2
.
Fig. 10
16. Install the PRINTER COVER 
Y
Y
Y
Y
.
Fig. 11
2) HEAD CABLE 
O
: Connect to the CN5.
Attach the FERRITE CORE 
V
 and CABLE
CLAMP 
4
.
Fix the CABLE CLAMP 
4
 with a SCREW 
X
.
26
22
13
21
16
19
4
28
: XEBSD30P08000
28
26
31
22
13
21
16
19
27
28
8
2
1
29
UP-3301V
LAN
– 12 –
1. LIST FOR SCREWs
2. INSTALLATION OF THE PAPER NEAR END SENSOR 
[PARTS LIST]
1) Remove the BOTTOM PLATE .
2) Remove the PS+CONTROL PWB .
3) Solder the CONNECTOR 
1
 to the PS+CONTROL PWB (No. CN1)
4) Install the NEAR END SENSOR UNIT 
3
 to the CABINET , and fix it
with the fixing SCREW 
2
.
Fig. 12
19. LAN
•  The LAN connection is standard using a RJ45 connector.
20. RS232 I/F: STANDARD
1) Connect the RS232 cable 
1
 to the desired connector.
2) Install the ferrite Core 
2
 to every RS232 cable installed.
No.
PARTS CODE
M [mm]
L [mm]
K
XEBSD30P08000
3
8
Z
X
S
-
a
XEBSD26P06000
2.6
6
S
-
b
S
-
c
XEBSD26P08000
2.6
8
S
-
d
7
XEBSD30P06000
3
8
U
No.
PARTS NAME
PARTS CODE
NOTE
1
PAPER NEAR 
END SENSOR
DUNTK3819BHZZ
SENSOR UNIT, 
FIXING SCREW
2
NEAR END 
SENSOR 
CONNECTOR
QCNCM6865RC0B
2 pin connector
L
M
L
M
1
3
2
3cm
RCORF6699BHZZ
1
2
UP-3301V
CONTACTLESS KEY
– 13 –
21. CONTACTLESS KEY
1) Remove the connector of a clerk key 
1
, Remove the two screws
2
, and remove the clerk key unit.
Remove the screw 
3
 and remove the clerk key.
2) Attach the contactless key to the plate. Attach the contactless key
unit to the upper cabinet with screws 
2
, and set the connector 
3
.
Attach the upper cabinet, attach the lid 
4
, and attach the cap 
5
tightly.
Note: The peojection 
A
 side of the lid 
4
 should be upper side.
Contactless key label
■ 
Attachment
 
HZ-R01CK
Note: In case contactless key attaches, be sure to attach CE-Mark label
(accessories) to a bottom cabinet.
Using contactless key of the product with which CE-Mark is not
attached is forbidden by law.
Refer to the following figure for the attachment position of CE-Mark.
1
2
3
4
5
1
2
3
A
Key label
Key
Key label size
2.7
12
R9.5
 0
-0.5
 0
-0.5
CE-MARK LABEL
25mm
q
SHARP CORPORATION
Digital Document Systems Group
Products Quality Assurance Department
Yamatokoriyama, Nara 639-1186, Japan
2003 July Printed in Japan 
t
2003 BY SHARP CORPORATION
All rights reserved.
Printed in Japan.
Page of 16
Display