DOWNLOAD Sharp XE-A213 (serv.man6) Service Manual ↓ Size: 1.7 MB | Pages: 100 in PDF or view online for FREE

Model
XE-A213 (serv.man6)
Pages
100
Size
1.7 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
ECR / XE-A213 Operation Manual
File
xe-a213-sm6.pdf
Date

Sharp XE-A213 (serv.man6) User Manual / Operation Manual ▷ View online

59
Part
3
 FOR THE  MANAGER
Part
2
Part
1
3. Footer print on receipt programming (Press 
s
to skip. / Press 
A
to terminate.)
4. Entry of amount tendered programming (Press 
s
to skip. / Press 
A
to terminate.)
LIMIT DIGITS    
               8
s
(2) Press the 
s
key to register the setting.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
(1) Go to (2) when the entry of amount tendered does
not need to be changed from "NON
COMPULSORY".  Otherwise, press 
:
key to
display "COMPULSORY".
Each time 
:
key is pressed, the display shows
"COMPULSORY" and "NON COMPULSORY"
alternatively.  In case of 
c
and 
b
programming,
"INHIBIT" is displayed instead of "NON
COMPULSORY".
Default setting is "NON COMPULSORY" or "INHIBIT".
AMOUNT TENDERED 
  NON COMPULSORY
s
(2) Press the 
s
key to register the setting.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
(1) Go to (2) when the footer print on receipt does not
need to be changed from "NO".  Otherwise, press
:
key to display "YES".
Each time 
:
key is pressed, the display shows
"YES" and "NO" alternatively.
Default setting is "NO".
This programming decides whether or not the
machine should print a message at the foot of a
receipt when a specified key is used.  With regard
to programming method of footer logo message,
refer to "Logo messages" section on page 25.
FOOTER PRINT    
              NO
s
(3) Press the 
s
key to register the text.
Immediately after displaying guidance message for
the next step, the current setting for the next step
will be displayed.
CHEQUE          
CHEQUE
(2) Enter the text.
A maximum of 16 characters can be entered.
Please refer to "Guidance for text programming" on
page 14 for entering the text.
When you start entering a character, the current
text data will be overwritten by new data.
Pressing the 
P
and 
@
key moves the cursor to
the right and left respectively.
 A213_3 FOR THE MANAGER(SEEG)  06.4.28 8:33 PM  Page 59
60
5. Entry digit limit programming (Press 
s
to skip. / Press 
A
to terminate.)
6. Terminate programming
Item:
Selection:
Print:
A
Footer print
No*
0
Yes
1
B
Amount tendered entry
Non compulsory (for 
X
and 
Y
)*
0
Inhibit (for 
c
and 
b
)*
0
Compulsory 1
C
Entry digit limit
0-8 (default:8)
Function parameters for 
A
*1:Item:
Selection:
Entry:
A
Footer printing*
Allow
1
Disallow*
0
B
Amount tendered entry*
Compulsory
1
Non-compulsory*
0
C
Entry digit limit
0-8 (default:8)
*
1
ABC 
A
To program   0  for all items
To program for another key
@
s
From left, ABC
Text
Print
            0.00
A
(1) Press the 
A
key to terminate the 
X
key
programming.
CH2 PROGRAMMING 
ENTER[00]KEY    
s
(2) Press the 
s
key to register the setting.
In the case of programming for the 
X
and 
c
keys, the display shows "CH2 PROGRAMMING"
and "CR2 PROGRAMMING" respectively.  Go to
step 2 to program the 
Y
and 
b
keys.
In the case of programming for the 
r
o
Y
and
b
keys, the display shows "ENTER[TL/NS]KEY".
Go to step 6.
               7
7
(1) Enter entry digit limit using numeric key.
The entry digit limit can be set up to 8.
Default setting is 8.
The entry digit limit is in effect for REG mode
operation but can be overridden in the MGR mode.
The entry digit limit is represented by the number of
allowable digits for the maximum entry or total
amount.  When "0" is set, the operation of the
corresponding key is prohibited.
 A213_3 FOR THE MANAGER(SEEG)  06.4.28 8:33 PM  Page 60
61
Part
3
 FOR THE  MANAGER
Part
2
Part
1
Footer printing
• This programming decides whether or not the machine should print a message at the foot of a receipt when
the 
A
key is used.  With regard to programming method of footer logo message, refer to “Logo messages”
section on page 25.
Amount tendered entry
• You may select amount tendered, compulsory or optional.  
Entry digit limit
• Program upper limit entry for total cash amount which can be handled on the register.  The entry digit limit is
in effect for REG mode operation but can be overridden in the MGR mode.  The entry digit limit is represented
by the number of allowable digits for the maximum entry or total amount.  When “0” is set, the operation of the
corresponding key is prohibited.
Please refer to “Guidance for text programming” on page 14 as for how to entering characters.
Foreign currency symbol
(4 digits)
Foreign currency symbol for the 
V
key is printed with a foreign currency exchange amount obtained using a
preset rate.
Domestic currency symbol
(4 digits)
” is set as a default setting.  When you want to change the domestic currency symbol, change the setting.
Domestic
currency symbol
Entry using
character code
s
85
P
S S S
207
:
s A
Print
Key operation example
Character keys 
(max. 4 digits)
A
s
To keep the current setting
s
P
85
Foreign currency
symbol
s
 6 
P
 US 
S
 $
s
 
A
Print
Key operation example
Character keys 
(max. 4 digits)
A
s
To keep the current setting
s
P
6
Other Text Programming
2
From left, ABC
018
@
s A
Print
Key operation example
 A213_3 FOR THE MANAGER(SEEG)  06.4.28 8:33 PM  Page 61
62
Training mode text
(12 digits)
For every receipts issued in the training mode, **TRAINING** is printed by default.  When you want to change
the text, follow the procedure below.
The programmed text is printed in double-size characters on the receipts issued in the training
mode.
Function text
(12 digits)
* Function no.: See “List of function texts” shown on the next page.
s
P
36 
@
CARD1 
s
A
(Programming CARD1 for
credit 1)
Print
Key operation example
s
P
@
*Function no. 
(max. 2 digits)
Character keys
 (max. 12 digits)
A
To keep the current setting
s
To program another function text
3
s
87 
P
S S
TRAINING 
S S
s A
Print
Key operation example
Character keys 
(max. 12 digits)
A
s
To keep the current setting
s
P
87
 A213_3 FOR THE MANAGER(SEEG)  06.4.28 8:33 PM  Page 62
Page of 100
Display