Procedure on P.C. side
No
Procedure on UP-600/700 side
7
Execute "POSUTILITUTOOL.EXE" on P.C.
*Don’t execute the other Software at the same time.
8
Select the ROM object Files by "Add Files.." button.
9
Push "SEND" button.
Program data is sent to UP-600/700 automatically.
9
Program data is received from P.C. automatically.
UP-600/700 shows
10
When sending is completed,
the initial Window is shown after "Complete" window.
10
UP-600/700 shows
"Completed."
11
Turn OFF the power.
12
Select "Normal Mode".
Set "IPL switch" to "OFF".
(Ref. Hardware manual)
13
Execute "Service Reset" on UP-600/700.
IPL from IR
Connected IRDA 115200
21 22 23 24 25 26 27 28
IPL from Serial I/O
Connected IRDA 115200
21 22 23 24 25 26 27 28
29 2A 2B 2C 2D 2E 2F
Completed.
IPL from Serial I/O
Connected IRDA 115200
30 31 32 33 34 35 36 37
38 39 3A 3B 3C 3D 3E 3F
Completed.
3) -2. 02FD
No
Procedure on P.C. side
No
Procedure on UP-600/700 side
1
Install "02FD.EXE" on the P.C.
ALL RAM Data UpLoad : Go to "2"
ALL RAM Data DownLoad : Go to "9"
2
ALL RAM Data UpLoad
Connect P.C. and UP-600/700 (CH2) via RS232. (Fig 1)
2
Enter the SRV mode.
Select " 2 SETTING ".
Select " 14 BACKUP SEND"
3
UP-600/700 shows
4
Execute "02FD.EXE" on P.C.
*Don’t execute the other Software at the same time.
5
Set the Communication method by "Setting" Button.
Push "OK" Button.
6
Push "Receive Start" Button.
And Select the Receiving File.
7
Communication starts.
7
Push TL key.  UP-600/700 shows
8
UpLoad is completed.
The initial Window is shown.
Push "Exit" Button.
8
UpLoad is completed.
The SETTING menu is shown.
9
ALL RAM Data UpLoad
Connect P.C. and UP-600/700 (CH2) via RS232. (Fig 1)
9
Enter the SRV mode.
Select " 2 SETTING".
Select " 15 BACKUP RECEIVE"
10
UP-600/700 shows
Push TL key.
SEND DATA                  ALL RAM
SPEED             PROGRAMMED SPEED
BACKUP SEND
SENDING            00000
BACKUP RECEIVE
SPEED           PROGRAMMED SPEED
No
Procedure on P.C. side
No
Procedure on UP-600/700 side
11
Execute "02FD.EXE" on P.C.
*Don’t execute the other Software at the same time.
12
Set the Communication method by "Setting" Button.
Push "OK" Button.
13
Push "Transmit Start" Button.
And Select the Sending File. 
14
Communication starts.
14
UP-600/700 shows
15
DownLoad is completed.
The initial Window is shown.
Push "Exit" Button.
15
DownLoad is completed.
The SETTING menu is shown.
16
Execute " Service Reset " on UP-600/700
3. NOTE FOR HANDLING OF LCD
The LCD elements are made of glass. BE careful not to give them
strong mechanical shock, or they may be broken. Use extreme
care not to break them.
If the LCD element is broken and the liquid is leaked, do not lick it.
If the liquid is attached to your skin or cloth, immediately clean with
soap. 
Use the unit under the rated conditions to prevent against damage.
Be careful not to drop water or other liquid on the display surface.
The reflection plate and the polarizing plate are easily scratched.
BE careful not to touch them with a hard thing such as glass,
tweezers. Never hit, push, or rub the surface with hard things.
When installing the unit, be careful not to apply stress to the LCD
module. If an excessive stress is applied, abnormal display or
uneven color may result.
RECEIVING          00000
CHAPTER 4. SRV. RESET AND MASTER RESET
The SRV key is used for operating in the SRV mode.
1. SRV. reset (Program Loop Reset)
Used to return the machine back to its operational state after a lock-
up has occurred.
Procedure
Method 1
1) Turn off the AC switch.
2) Set the mode switch to (SRV’) position.
3) Turn on the AC switch.
4) Turn to (SRV) position from (SRV’) position.
Method 2
1) Set the mode switch to PGM2 position.
2) Turn off the AC switch.
3) While holding down JOURNAL FEED key and RECEIPT FEED
key, turn on the AC switch.
Note: When disassembling and reassembling always power up us-
ing method 1 only. Method 2 will not reset the CKDC9.
Note: SRV programming job#926-B must be set to "4" to allow PGM
program loop reset.
PRG. RESET
2. Master reset (All memory clear)
There are two possible methods to perform a master reset.
MRS-1
Used to clear all memory contents and return machine back to its
initial settings.
Return keyboard back to default. for default key-board layout.
Procedure
1) Turn off the AC switch.
2) Set the MODE switch to the (SRV’) position.
3) Turn on the AC switch.
4) While holding down JOURNAL FEED key, turn to (SRV) posi-
tion from (SRV’) position.
MRS-2
Used to clear all memory and keyboard contents.
This reset returns all programming back to defaults. The keyboard
must be entered by hand.
This reset is used if an application needs different keyboard layout
other than that supplied by a normal MRS-1.
Procedure
1) Turn off the AC switch.
2) Set the MODE switch to the (SRV’) position.
3) Turn on the AC switch.
4) While holding down JOURNAL FEED key and RECEIPT FEED
key, turn to (SRV) position from (SRV’) position.
5) Key position assignment:
After the execution of MRS-2, only the RECEIPT FEED and
JOURNAL FEED keys can remain effective on key assignment.
Any key can be assigned on any key position on the main key-
board.
[key setup procedure]
MASTER PRESET
NOTES:
*1: When the 0 key is pressed, the key of the key number on
display is disabled.
*2: Push the key on the position to be assigned. With this, the key
of the key number on display is assigned to that key position.
*3: When relocating the keyboard, the PGM 1/2 mode use stand-
ard key layout.
Key
No.
Key
name
Key
No.
Key
name
Key
No.
Key
name
001
011
021
002
012
022
003
013
023
004
014
005
015
006
016
007
017
008
018
009
019
010
020
MRS-2 executed
Key position set
Free key
Disable
Free key setup
complete.
*2
*1
0
0
Page of 51
Display

Click on the first or last page to see other UP-600 / UP-700 (serv.man25) service manuals if exist.